Loading...
HomeMy WebLinkAboutOrdinance No. 19-1984'MICRC F ?,R.f'ED 4 -15.35 ORDINANCE NO. 19 -84 AN ORDINANCE AMENDING CHAPTER 623, "SPECIAL INSPECTOR - THRESHOLD BUILDINGS" OF THE CODE OF ORDINANCES OF THE CITY OF CAPE CANAVERAL, FLORIDA, BY REPEALING CHAPTER 623 IN ITS ENTIRETY AND SUBSTITUTING, THEREFORE, A NEW CHAPTER 623, "SPECIAL INSPECTOR - THRESHOLD BUILDINGS "; DEFINING THRESHOLD BUILDINGS AND PROVIDING GUIDELINES FOR THE QUALIFICATIONS OF THE SPECIAL INSPECTOR; ADOPTING FLORIDA CHAPTER 83 -160 OF THE LAWS OF FLORIDA AS AMENDED BY SENATE BILL 399; REPEALING ALL PORTIONS OF THE CODE IN CONFLICT HEREWITH; PROVIDING AN EFFECTIVE DATE. BE IT ORDAINED by the City Council of the City of Cape Canaveral, Florida, as follows: SECTION 1. Chapter 623, "Special Inspector - Threshold Buildings ", of the City Code of the City of Cape Canaveral, Florida, is hereby repealed in its entirety and replaced with the following: CHAPTER 623 SPECIAL INSPECTOR - THRESHOLD BUILDINGS Sec. 623.01 Laws of Florida Adopted. Chapter 83 -160, Laws of Florida, Special Threshold Building Inspector, as amended by Senate Bill 399, is hereby adopted by reference as though it were copied here in full. Sec. 623.03 Definitions. The following definitions are adopted in addition to the statute: (A) Special Inspector shall be a person certified, licensed or registered under Chapter 471, as an engineer or Chapter 481, as an architect. All such persons must have demonstrated and proven capability to inspect structural components of threshold buildings as defined herein. (B) Threshold Building means any building which is greater than three stories or 50 feet in height, or which has an assembly occupancy classification that exceeds 5,000 square feet in area and an occupant content of greater than 500 persons. ORDINANCE NO. 19 -84 PAGE 1 OF 4 MSC OF 4 -1535 (C) Structural Components - Structural components are as follows: Compaction of fill, footings, piling, pile caps, grade beams, floor slabs, bearing walls, columns, tie beams, lintels, reinforcing steel, shoring, reshoring, roof slabs, roof assembly, stair assembly, all structural elements de- pending upon one another for continuity or support, and fire resistive structural components are included, and any other specific requirements of Chapter 83 -160, Laws of Florida. Sec. 623.05 General Provisions. The following general provisions are adopted in addition to the State Statute: (A) The Special Inspector shall be retained by the owner of the Threshold Building and shall be approved by all parties prior to the construction of any structural components. (B) Any person, other than the state certified Special Inspector, who is sent to the job site as a.duly authorized representative of the Special Inspector to perform inspections, must meet the requirements of the Standard Building Code, Section 102.2 and be approved by the Building Official. (C) The Special Inspector shall be on the job at ALL times structural components are being constructed or placed. ALL elements of structural installation must be observed and approved by the Special Inspector. (D) The Special Inspector shall possess an insurance policy for Errors and Omissions with the minimum limits of $500,000 per occurrence and $1,000,000 aggregate. Special Inspector shall provide a copy of his certificate of insurance and specific policies involved to the City Building Official prior to commencing performance of his duties and responsibilities. Said insurance policies shall provide that the City shall be entitled to fifteen (15) days prior written notice of any changes or cancellation of said policies. Said policies shall remain in effect for three (3) years from the completion date on the last project on which the Inspector has performed services. In lieu of said insurance coverage, a surety bond for one million dollars may be posted by and for the Special Inspector. (E) The structural inspection plan prepared by the engineer or architect of record must be approved by the Building Official and must contain at least the following requirements: ORDINANCE NO. 19 -84 PAGE 2 OF 4 M CP, OF 5 D 445-85 (1) Spot checks, at least daily, of all structural operations and all operations relating to the structural integrity of the building. (2) Inspection of all materials and procedures to be used during any structural operation, done when that operation is commencing. (3) Inspection of any and all structural components before they are "covered up ". (F) The shoring and reshoring plans must be approved and sealed by the engineer of record and submitted to the Building Official prior to the issuance of the building permit. (G) Only those plans and specifications carrying the Building Department's stamp shall be used for inspections. No changes or deviations from the permitted plans and specifications will be per- mitted until the architect or engineer of record has cleared same through the Building Department. (H) The Special Inspector shall submit daily inspections /progress reports in writing to the City for all time on the job site, related to structural inspections. (I) The City will accept any daily report from the Special Inspector that provides the following information: a. Report on company letterhead b. The date and time of inspection c. Job name and complete address d. Detailed report noting any and all changes and /or corrections e. The Inspector's approval f. The signature of the Inspector under his /her printed name (J) The City will maintain a copy of the daily reports as submitted by the Special Inspector. These records will be sworn evidence of the Inspector's findings during his review of the project work. (K) The contractor shall schedule a dual inspection with both the Special Inspector and the City Building Inspector, of all structural components prior to "cover up" or pouring of concrete, etc. (L) The Special Inspector shall notify the Building Department immediately when non - compliance is discovered and noted. ORDINANCE NO. 19 -84 PAGE 3 OF 4 MICROFILMED 4.15 -85 (M) The City hereby agrees to convene a meeting with all interested parties whenever a Stop Work Order is issued. Said meeting shall be at a reasonable hour, within 24 hours of the Stop Work Order issuance. (N) The Special Inspector shall cooperate fully with the Building Department and its authorized agents in the execution of its duties and responsibilities. Sec. 623.07 Penalty. Any person violating any of the provisions of this Chapter shall be punished as provided in Sec. 801.01. SECTION 2. All portions of the code in conflict herewith are hereby repealed. SECTION 3. This ordinance shall take effect immediately upon its adoption. ADOPTED by the City Council of the City of Cape Canaveral, Florida, this 2nd day of October 1984. NAME YES NO CALVERT X FISCHETTI NICHOLAS X RUTHERFORD X WINCHESTER PERMISSION TO ADVERTISE: 9 -4 -84 First Reading 9 -18 -84 Posted: 9 -6 -84 Advertised: 9 -14 -84 ocond Reading: 10 -2 -84 ORDINANCE NO. 19 -84 PAGE 4 OF 4