Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
07 A-205 Roof
MAU-1 MAU-2 34x22 30x3032x20 22x30 1 3 4 6 8 9 10 11A 11B 12 13 14 15 17 18 20 1 A-303 2 19 16 1 A-401 2 A-401 3 A-402 4 A-402 5 A-403 6 A-403 7 A-404 48"x48" ROOF ACCESS HATCH ON 12" CURB2 A-508 EXPANSION JOINT COVERSLOPESLOPESLOPESLOPESLOPESLOPESLOPESLOPESLOPE SLOPESLOPESLOPESLOPESLOPESLOPESLOPESLOPESLOPESLOPE SLOPE SLOPESLOPESLOPESLOPESLOPESLOPESLOPESLOPESLOPE SLOPE SLOPE SLOPE SLOPE SLOPE SLOPESLOPESLOPESLOPESLOPE SLOPESLOPE SLOPESLOPE SLOPESLOPESLOPESLOPE LINEN CHUTE EXHAUST CAP ELEV #1 & #2 ROOF ELEVATOR OVERRUN: TPO ROOFING ON TAPERED RIGID ROOF INSUL. (R-25). (SLOPED 1/4" PER FOOT TOWARDS LEADER) 4" X 6" PREFIN. ALUM. GUTTER W/ 4" SQUARE DOWNSPOUTS (COLOR TO MATCH ADJACENT WALL COLOR). TPO ROOFING ON TAPERED RIGID ROOF INSUL. (R-25). (SLOPED 1/4" PER FOOT TOWARDS ROOF DRAINS) T PO ROOFING ON TAPERED RIGID ROOF INSUL. (R-25). (SLOPED 1/4" PER FOOT T OWARDS ROOF DRAINS) T PO ROOFING ON TAPERED RIGID ROOF INSUL. (R-25). (SLOPED 1/4" PER FOOT T OWARDS ROOF DRAINS) LOCATE BLDG. SIGN ELEC. BEHIND PARAPET WALL; RUN EMPTY CONDUIT INSIDE EXT. WALL ASSEMBLY DOWN TO SIGN(S). COORD. w/ OWNER'S SIGN VENDOR. D.S. TOILET EXHAUST HOODS; RE: MECH. ROOF WALKING PADS, COORDINATE SIZE AND INSTALLATION W/ ROOFING MANUFACTURER R.D. O.R.D R.D. O.R.D R.D. O.R.D R.D. O.R.D R.D. O.R.D R.D. O.R.D R.D. O.R.D R.D. O.R.D R.D. O.R.D R.D. O.R.D O.R.D. R.D. O.R.D. R.D. SLOPE SLOPE13'-4 1/2" 13'-4 1/2" 13'-4 1/2" 13'-4 1/2" 13'-4 1/2" 13'-4 1/2" 13'-4 1/2" 13'-4 1/2" 13'-4 1/2" 13'-4 1/2" 13'-4 1/2" 13'-4 1/2" 13'-4 1/2" 13'-4 1/2" 9" 13'-4 1/2" 13'-4 1/2" 13'-4 1/2" 13'-4 1/2" 13'-8"13'-4 1/2" 13'-4 1/2" 13'-6" 13'-6" 13'-4 1/2" 13'-4 1/2" 13'-6" 255'-2" CONTINUE 2" EXPANSION JOINT UP PARAPET WALL & THRU CAP FLASHING (TYP) CLAMPING RING ROOF INSULATION TAPERED TO DRAIN TPO SEALING MASTIC 2" (50 mm) WIDE, 1/4" (8 mm) THICK MIN. 1" (25mm) EXTENSION OF MEMBRANE BEYOND RING STRAINER BASKET TPO MEMBRANE TPO PEEL & STICK PIPE FLASHING CLAMPING RING (BY OTHERS) TPO SEALING MASTIC RAIN HOOD WITH CLAMP AND HIGH TEMPERATURE SEALANT TPO PEEL & STICK PIPE FLASHING TPO MEMBRANE TPO ANCHOR DISC WITH ACCEPTABLE FASTENER (NOTE 1) OUTER PIPE SLEEVE THERMAL INSULATION (IF SPECIFIED)TPO TAPE PRIMER / WASH NOTES: 1. MEMBRANE MUST BE MECHANICALLY ATTACHED WITH EPDM ANCHOR DISC WITH ACCEPTABLE FASTENERS 6" (150mm) CENTERS AROUND PROJECTION. 2. DO NOT OVERLAP THE FLANGES FROM ADJACENT PIPE FLASHINGS ROOF - GENERAL NOTES: 1. ALL FLASHINGS @ PARAPETS, RELIEF SCUPPERS, ROOF DRAINS, FANS, SUPPORTS, ETC. TO BE PER STANDARD DETAILS OF ROOF SYSTEM MANUFACTURER. 2. ALL ROOF INSULATION BOARD TO HAVE MINIMUM R-FACTOR OF 25.0 & THE TOP LAYER OF ALL ROOF INSULATION BOARD SHALL BE TAPERED TO PROVIDE 1/4" PER FOOT SLOPE FOR ROOF DRAINAGE. 3. ALLOW 12" MINIMUM BETWEEN EACH ROOF CURB/PENETRATION, FROM PARAPET WALLS, AND ROOF CURBS TO ALLOW INSTALLATION OF WARRANTED ROOFING FLASHING DETAILS. 4. NO ROOF PENETRATION WITHIN 36" OF ROOF DRAINS OR EMERGENCY OVERFLOW DRAINS. 5. ALL ROOF PENETRATIONS TO BE WATER TIGHT ABOVE ROOF FLASHING. 6. NO PITCHPOCKETS PERMITTED ON ROOF. USE STANDARD DETAILS OF THE ROOF SYSTEM MANUFACTURER. 7. PROVIDE POSITIVE SLOPE AT ALL AREAS EXPOSED TO WEATHER. 8. TYPICAL DOWNSPOUT SHALL BE 4" x 4" PREFINISHED METAL TO MATCH PREFINISHED METAL GUTTER. 9. ALLOW 12" MINIMUM BETWEEN EACH WALL PENETRATION, ABOVE OR BELOW GRADE, TO ALLOW INSTALLATION OF WATERPROOFING AND AIR BARRIER SYSTEM FLASHINGS PER MANUFACTURER'S DETAILS. 10.ROOF WALK PADS: PROMPTLY INSTALL PROTECTIVE WARRANTED WALK PADS TO BETTER LIMIT COMPRESSING INSULATION AND/OR CUTTING/PUNCTURING THE FIELD MEMBRANE. 11.PROTECT THE ROOFING SYSTEM AT ALL TIMES WHEN INSTALLING ROOF TOP EQUIPMENT AND PENETRATIONS. COORDINATE WITH GC AND ROOFING SUBCONTRACTOR. 12.GC TO INSTALL AND SEAL ALL ROOF PENETRATIONS, CURBS & SLEEPERS. 13.HVAC VENDOR TO PROVIDE ROOF CURBS AND BE RESPONSIBLE FOR COORDINATION OF ROOF PENETRATIONS REQ'D FOR EQUIPMENT I NSTALLATION. 14.SATELLITE DISH: GC TO PROVIDE SUPPORT LEGS/BLOCKING. 15.GC TO PROVIDE POWER & BLOCKING FOR ALL BUILDING SIGNAGE, COORD. W/ SIGN VENDOR. 16. R.D. ROOF DRAIN O.R.D. OVERFLOW ROOF DRAIN D.S. DOWNSPOUT 48" X 48" THERMALLY BROKEN ROOF HATCH w/ LOCK - SLOPE ROOF AROUND ROOF HATCH TPO ROOFING ON RIGID ROOF INSUL. (R-21.8) - SLOPE 1/4" / FT. TOWARDS ROOF DRAINS RUN EPDM ROOFING UNDER ROOF HATCH FLASHING ROOF HATCH FLANGE ANCHORED TO TREATED WOOD BLOCKING AROUND PERIMETER OF OPENING STAINLESS STEEL GAS SPRING ASSISTED LIFT FILL GAP WITH BACKER ROD & SEALANT 10" MIN.7975 Stage Hills Boulevard, Suite 4 Memphis, Tennessee 38133 T. (901) 377-6603 F. (901) 388-5765 http://www.bgktarchitects.com These plans were derived from the Holiday Inn Express by IHG design and construction standards and are confidential and proprietary to IHG and may not be reproduced, disclosed, distributed or used without the express permission of an authorized representative of BGKT Architects, PLLC. © 2021 BGKT Architects, PLLC. Sheet: Date:Consultant:Project No:MarkDateRevisionBOUNDS GILLESPIE KILLEBREW TUSHEK Drawings, electronic media, design concepts and related material shall not be used, modified or reproduced in whole or in part by any persons or companies without prior written consent of BGKT Architects, PLLC ARCHITECTS, PLLC MEMPHIS HOUSTON 091920 06-21-2021 A-205ROOF PLAN995 Shorewood Drive, Cape Canaveral, FL 32920HOLIDAY INN EXPRESS& SUITESSCALE: 3/32" = 1'-0"1 FLOOR PLAN - ROOF SCALE: 1" = 10'-0"2 ROOF DRAIN DETAIL SCALE: 1" = 10'-0"3 PIPE FLASHING DETAILS SCALE: 1/2" = 1'-0"4 ROOF HATCH DETAIL 09-01-2021 FOR CONSTRUCTION 06-21-2021 FOR BUILDING PERMIT STAT E O F FLO R I DAREGI ST ERED A R C H ITECT09-13-21 Received by MCCI 09-14-2021 J Arthur Killebrew J Arthur Killebrew C=US, E=a.killebrew@BGKTar chitects.com,O="BGKT Architects, PLLC", CN=J Arthur Killebrew 2021.09.14 10:17:38-05'00'