Loading...
HomeMy WebLinkAboutBalcony Restoration Specs 15'-0" --::t-------- TIP~ '""'" \ co . #5 TOP & BTM I ~ 00 0.. 0 12" O.C. I o . I #5;<10' 12" O.C. IN TOP #4;<3" LQNG .' ol!) I- '" ~ DRill "(HROUGH Ql'i\DING 5/8"'1.5/8"'1. 1/8" HR STL BACKE.RS . . .0 - I \ WALLS AND sET IN EPOXY ANGLE ASTM 1>.36 MAY BE =ll= . . ----- _--------1-"- ------ SUBSTITUTED IN PLACE OF #4'1.3" LONG BACKERS --- . ~ ".4 .~ --------------~---~- l __--------- _J---~ \ \ OP1'\ONAL WELD DETA\L - - - - A USE WHERE LAP SPLICE LENGTH IS INSUFfICIENT INTERIOR SLAB REPAIR, IF ANY EXISTING STEEL. LEAVE MIN. 32" TO BE DETERMINED IN FIELD LINE OF DEMOLITION EXTENDING FROM AND BILLED AT UNIT COST fOR BALCONY UNIT INTERIOR SLABS REPLACEMENT W ~EINFORC\NG 1~~_:'T UNIT 204- NOTES: UNITS 201, 205, 208, 210 TYPICAL i. ALL DIMENSIONS ARE TO ROUGr! FRAMING OR MASONRY. CONTRACTOR SHALL FIELD VERIFY DIMENSIONS PRIOR TO CONSTRUCTION. 2. CONCRETE SHALL ATTAIN MIN. 5000 PSI r PROVIDE DRIP COMPRESSIVE STRENGTH AT 28 DAYS. / ~r;rCH IN "VEE. REINFORCING STEEL Sr!ALL 8E ASTM A615 ___ . OR RAIlIUS FORM GRADE 60. MINIMUM 1-1/2" cLEAR COVER 3/4:" STEP AT ---=11\\ DOOR TRACK NEW WE.LDE.D ALUMINUM - II REQUIRED OVER ALL REINFORCING. / '\. ,- GUARDRAIL FLANGE MOUNT. \ ;::!';::::::;~u 3. REFER TO PROJECT SPECIFICATIONS 11- 2" T8D \~~ W/3/8"x3" 5.S. S1UD5 \ ~-;1k) FOR WORK PROCEDURES, MATERIAL SET 11'1 EPOxY / SPECIFICATIONS. AND ADDITIONAL BALCONY EDGE DETA\L INFORMATION ~ , - .:.....-- 4.. Tr!IS REPAIR DESIGN IS IN SU8SiAN1\AL ~ \ MIN. 1 _1/2. COYER COMPLIANCE WITH THE REQUIREMENTS OF OVER ALL STEEL, TOP r ADDL. #5;<10' TOP THE FLORIOA 8UILDING CODE 2001 FOR & BoTTOM SEE PLAN vIEW 130 MPH WIND SPEED. NO CERTIFICATION ~ \ AnDL. 2-#6 BARS ~ \ ADDL. #5 81M IS IMPLIED FOR Tr!E REMAINDER OF THE EXISTING STRUCTURE. SEE PLAN VIEW ~ BOTTOM PROJECT l!) THE CEDARS CONDOMINIUM \ BALCONY RECONSiRUCT\ON MINIMUM 2" #5 DOWELS W jOFfSET .J #4 8ARS 12" Q.C.-' CLE.AR CONC. CAPE CANAVERAL, FL Ul'lITS 201. 204. 205. 208, 210 \ COVER OVER BEt~D Ai 12n O.C. \ e/W TOP & BOTTOM OUTER siEEL EPOXY 12n INTO EXSTG. OAVlO L BAY ANT DATE SLAB. EXTEND 16" INTO ihis plan has been prepared u'Icler my 2/06/03 BALCONY DECK direct supeoision and is, to the best of PROfESSIONAL ENGINEER my knowledge, QCcurate and in compli- aRAWN once with 0\\ oppliCoble building codes, CI P.O. 80)( 362024 n ~ t \ M};~~U~~~:,:~0~~DA~.?3?3~ " \ ^ .I I / J I RE'i @JlPICAL SEC1!QN THRU BALCONY \ o,K''- e,v'-"O'- wvoo,5~ ~1Jl " ..,!g!b ow~ ~ ~~ o,~'~-_ MM _ -==.~~?~1::2-~_ I ! ~j \ t\jt~k'K t~Lt l ~ ... , -~- ~-_.._.._----_._...._._---_._-_. --. -..,....-.- 15'-0" -- ------,- nP~ co . #5 TOP & BTM I ~ 0 0.. 0 12" O.C. I o . I #5x10' 12" O.C. IN TOP #4x3" LQN9 . l!) I- '" r DRILL THROUGH DNlDING 5/8"x5/8"x1/8" HR STL BACKERS - .0 - I I WALLS AND SET IN EPOXY ANGLE ASTM A36 MAY BE . . =ll= -------t- SUBSTITUTED IN PLACE OF #4x3" LONG BACKERS --- " ______________~---t l ___________ _J___+ \ I o OPTIONAL WELD DETAIL - - USE WHERE LAP SPLICE LENGTH IS INSUFFICIENT INTERIOR SLAB REPAIR, IF ANY EXISTING STEEL, LEAVE MIN. 32" TO BE DETERMINED IN FlELD LINE OF DEMOLITION EXTENDING FROM AND BILLED AT UNIT COST FOR BALCONY UNIT INTERIOR SLABS REPLACEMENT <W' REINFORCING 1~~~_:T UNIT 202 NOTES: UNITS 203, 206, 207, 209 TYPICAL 1- ALL DIMENSiONS ARE TO ROUGH FRAMING OR MASONRY. CONTRACTOR SHALL FIELD VERIFY D1MENSlot..jS PRIOR TO CONSTRUCTION. 2. CONCRETE SHALL ATTAIN MIN. 5000 PSI r PROVIDE DRIP COMPRESSIVE STRENGTH AT 28 DAYS. ~OTCH IN "'lEE:" REINFORCING STEEL SHALL 8E ASTM A615 ___ OR RADIUS FORM GRADE 60. MINIMUM 1-1/2" CLEAR COVER ---=ej) REQUIRED OVER ALL REINFORCING. NEW WELDED ALUMINUM - 1\ GUARDRAIL FLANGE MOUNT. \ :::."'==:> u 3. REFER TO PROJECT SPECIFiCATIONS W/3/8"x3" S.S. STUDS \ ~~/ FOR WORK PROCEDURES, MATERIAL SET IN EPOXY - -J SPECIFICATIONS, AND ADDITIONAL INFORMATION BALCONY EDGE DETAIL . THIS REPAIR DESIGN IS IN SUBSTANTIAL "- ''t. -H= \ MIN. 1 -1/2" COVER COMPLIANCE WITH THE REQU1REMEt...JTS OF ton ~ \ OVER ALL STEEL. TOP rADDL. #5x10' TOP THE FLORIDA 8UILDING CODE 2001 FOR & BOTTOM SEE PLAN Vlt:# 130 MPH WIND SPEED. NO CERTIFICATION \ '\ ADDL. #5 8TM IS IMPLIED FOR THE REMAINDER OF THE EXISTiNG STRUCTURE. SEE PLAN VIEW ~ PROJECT # _.-- ,.- . .\ THE CEDARS CONDOMINIUM BALCONY RECONSTRUCTION MINIMUM 2" #5 DOWELS W/OFFSET.J CLEAR CONC. CAPE CANAVERAL, FL UNITS 202, 203, 206, 207, 209 4 t:lAK::i :/.- U.\;.-" COVER OVER \ BEND AT 12" e.c. 8/V-~ TOP &; BOTTOM OUTER STEEL BEAM TOP STEEL TO BE EPOXY 12" INTO EXSTG. DATE I REPAIRED W / su.,B SLAB, EXTEND 16" INTO DAVID L. BRYANT This plan has been prepared under my 2/06/03 REPu.,CEMENT BALCONY DECK direct supervision and is, to the best of PROFESSIONAL ENGINEER my knowledge, accurate end in compli- DRAWN once with all applicable building codes. C\ P.O. 80X 362024 REI/. MEL80URNE, FLORIDA 32936 @ TYPICAL SECTION THRU BALCONY STATE L\CE~~SE PE-038154 DWG. NO. (321) 773-9900 221002-08 --- -- --.----- - --~._.....~--_._------------_.._-~-_._---_...._._._._..- ___________n._____ ~.................. -- ~- p,~ 15' _On 8n 15'-0" p,n 15' -0" Bn 15' -0" n 15'-0" 8. 15' -0. p,. B" 15' -0. . 15'-0" \ \ 15' -0. \\ ~ \ e I . 0 , \ /~ISilNG 8" SLOCK it> . pf>R\\T\Ol-l wpJ.l... TI'? 0 \ -- ---- :=::.--' ::.---' o.:::::::--r it> ---- :=::.--' -- ---- --:::: :::::---' - :::::..---' :::.---' :::::..---' . :::::--' ... .. A 8 UNIi 207 . UNIT 208 UNIT 209 UNIT 210 UNIT 205 UNll 206 OVE.R BORM OVER pI>,TIO O\lE.R BDRM UNll 202 UNIT 203 UNIi 2M OVER BDRM OVER ?I>,TIO OVE.R 1'1>,110 UNI! 201 OVER 1'1>,1\0 OVER BORM OVE.R BORM OVER ?/>.TIO 0 2nd fLOOR PLAN 3/32"::=1'-0" NOlES: I. El8lAiED 8ALCONY AREA 75 sF PER UNli 2. ALL DIMENSIONS ARE TO ROUGr! FRAMING OR MASONRY, CONTRACTOR SHALL FIELD VERlFi DIMENSIONS PRIOR TO CONSTRUCTION. 3. REFER 10 PROJECT SPECIFICATIONS FOR WORK PROCEDURES. MATERIAL SPECIfiCATIONS. AND ADDITIONAL INfORMATION r REPLACS BALCONY rREPLACE BALCONY / DEC\<.s. \YPIC,t>..L \~:'o DECKS, TYPICAL ~'~\- fNE UNliS FIVE UNliS I NEW GUARDRAIL G: ~oJ \--IEW GUARDRAIL W\iI-I G: oJ \~ WITH SCREEN ENCLOSURE &: / SCREEN ENCLOSURE ~ .L\ w L :> TYPE B BARRIER TYPE B BARRIER '3 SEE OWG. #221002-05 ~ ~ SEE OWG. #221002-05 SUBJECT PROJECi LA'< 0 U'T W THE CEDARS CONDOMINIUM 8U\LO\NG G: \.>.. . .0 /NEW SCREEN 0 V.~ ENCLOSURE V.~ r- E)l.ISilNG MASONRY CAPE CANAVERAL. FL E)l.ISiiNG GRADE \ \ / WALL DATE 2/06/03 \ 0/).'/\0 L. Bf\'lANT Tnis p\ai'\ noS beei'\ prepared ui'\der my .1--- SLAB. NO WORK 1-- "ced ,"p'''''''oO oOd ,', \0 t", be',.o1 my "ow"dg" 0000CO" ood .'0 ,"mp"- DRAWN CI PROfESSIONAL ENGINEER ai'\Ce \fiit\'1 01\ applicable bU\\d'f\9 codes. @ SECT,\~.~-o" OVER BDRM p.O. 80X 362024- Rf)/. o SEci,\?~~. O\f€.R PATIO MEL80URNE. flORIDA 32936 STAlE LICENSE. PE-038 i 54 0'; QWG. NO. 22 i 002-07 (32'\) 773-9900 .~~ ~- ----------~---- ---------- -..