Loading...
HomeMy WebLinkAboutBLDG PERMIT #19-0909 (A/C) 4/17/19 #305 4pCE aN O •I:_ = / .� City of Cape Canaveral, Florida Building Permit %11101r— PERMIT#19-0909 CUSTOMER#005416 PHONE: 321-868-1220 INSPECTIONS: 321-868-1204 FAX: 321-868-1247 PERMIT INFORMATION LOCATION INFORMATION Permit#: 19-0909 Issued:4/17/2019 Address:230 Columbia Dr Unit#305 Permit Type: MER Cape Canaveral FL, 32920 Cost: 3910.00 Total Fees: 119.00 PERMIT EXPIRATION DATE: 10/14/2019 Amount Paid: 115.00 Date Paid:4/17/2019 CONTRACTOR INFORMATION OWNER INFORMATION Name: Ray Brown A/C Heating & Refrigeration Name: Mark Wilmore Addr: 3815 N US 1 Ste#65 Address: 230 Columbia Dr Ste Unit#305 Cocoa, FL 32926- Cape Canaveral FL, 32920 Phone: (321)639-9205 Phone: (805) 291-0044 State Lic#: CAC1814446 Local Lic#: APPLICATION FEES i BP-Main:85.00 BP-Plan:0.00 After the Fact:0.00 I BP-Surcharge:4.00 Fire Plan Review:0.00 Re Inspection Fee Paid:0.00 Plan Revision Fee:30.00 Plumbing: Mechanical: Date Plan Revision Fee Paid: Electrical: Sewer lmapct: Temp CO: Capital Expansion: Sewer Tap: Concurrency: INSPECTIONS(for complete list of required inspections refer to Hard Card) NOTE: Once an inspection is approved by an authorized inspector the permit expiration date is extended six(6)months from date of inspection. Permit Desc:A/C CHANGE OUT INSPECTION APPROVED BY: DATE: NOTICE:THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 6 MONTHS,OR IF CONSTRUCTION OR WORK IS SUSPENDED, OR ABANDONED FOR A PERIOD OF 6 MONTHS AT ANY TIME AFTER WORK IS STARTED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS DOCUMENT AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR ANY ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Sign&Date s / ti' L 11 -1 b , A ' • 'I EDS - 'I 'E/ DATE ISSUED/DATE I-- PrintA7/ A,,..--- j-C— PRINT -PRINT NAME r,z,:h -rc,r--, a00 !K". ` kort _...CO r , Application Fee:S30.00 City of Cape Canaveral l►�,I 100 Polk Avenue,Cape Canaveral,FL 32920 • Phone(321)868-1220 Fax(321)868-1247 buildingforms@cityofcapecanaveral.org j3k Permit#)1-Q r Tracking 0 App.Date: I i) /7 Permit Total: I 1,574 0 APPLICATION FOR BUILDING PERMIT Florida Building Code in effect: 6th Edition Property Information TWP: RNG: SEC: SUB#: BLK/PAR: LOT: Site Address: /..10 en) Urn blCz_ )r. Owner Name: Ynnr f LCA I mn re_ Phone: F05-4,719/- 60c1(/ Owner Address: m P_ Contractor Information (Applicant) Qualifier Name: Ray E. Brown, Jr. Qualifier Address: 3815 N US Hwy 1,#65, Cocoa, FL 32926 License: CAC1814446 Company Name: Ray Brown Air Conditioning Heating & Refrigeration, Inc. Phone: 321-639-9205 Fax: 321-693-9465 Email: ray@raybrownac.com Project Information(Applicant) [ Residential 0 Commercial Site Plan#: Describe Work to be Done: 4/6 Chet r e o . Cost of Project: $ Its OCA Proposed Sq.Ft.: (copy of contract required) (total new construction) Subcontractor Information First& Last Name(Print) License Phone Plumbing Electrical IIVAC Roofing Specialty City of Cape Canaveral Building Permit Application—04/2019 Pg.I Site Address: d.5() C.O//,trn r *OD D 5' Owner Name: m ' l (A)i I ill or f� WARNING TO OWNER YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE YOU SCHEDULE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Initial: NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county or that may be required from other governmental entities such as water management district,state agencies or federal agencies. APPLICANT'S AFFIDAVIT Application is hereby made to obtain a permit to do the work and installations as indicated.I acknowledge and accept responsibility for compliance with all applicable codes,regulations and ordinances as well as the payment of all legally constituted fees regarding this development application, including but not limited to ALL REVIEW FEES, PERMIT FEES,IMPACT FEES AND RESERVATION FEES. Contractor Name(Print): Ray E. : own, Jr. Contractor Name(Signature): Owner/Agent(Owner Build/'y)(Print): Owner/Agent(Owner Builder///erOnly) (Signature): Date: q State of Florida,County of Brevard Subscribed and sworn to before me this I(v 11 day of I/t, ._ ?0_ personally appeared (I , t-2-13 r cs u;n ,Sr who •' personally kn� to me or produced as identification,and who did/did not take an oath. `��— 'J Notary Public State of Florida Notary Public Signature/Seal: �►VA". .„,„ ��1�.ii =' t jr My Commission FF 951518 or of Expires 07/10/2020 DISCLAIMER:The City of Cape Canaveral's approval of this development permit does not create any right for the permittee to obtain a permit from a state or federal agency.Further,pursuant to section 166.033,Florida Statutes,the City of Cape Canaveral shall not be liable for issuance of this development permit in the event a permittee fails to obtain any other required approval, fails to fulfill obligations imposed by a state or federal agency,or undertakes actions that result in a violation of state or federal law. The issuance of this development permit is expressly conditioned upon the permittee obtaining all other applicable state or federal permits,if any, prior to the commencement of the development authorized by the City's development permit. FINAL INSPECTION IS REQUIRED—Failure to obtain a final inspection may result in penalty. City of Cape Canaveral Building Permit Application—04/2019 Pg.2 Ray Brown Air Conditioning&Heat, Inc. Estimate 3815 N.US 1, Suite 65 Cocoa,FL 32926 Date Estimate# 321-639-9205 4/15/2019 3552 Name I Address Wilmore,Mark 230 Columbia Dr Apt 305 Cape Canaveral,FL 32920 Project Item Description Qty Cost Total Installation Installation of a new Ruud 1.5 ton 14.5 seer 410 A 3,595.00 3,595.00 (environmentally friendly freon)straight cool split system Ruud air handler and Ruud condensing unit with up to 5kw heat, float switch,outside electrical whip,anchors for condensing unit,locking caps,and new digital thermostat secondary drain pan also replace the disconnect box in air handler closed. We will use existing copper,thermostat wire,hurricane stand,air handler stand,drain line,electrical,breakers,if any other modifications(parts)are needed,it comes at an additional charge. Newer systems have a higher efficiency rate and could possibly produce more air flow.This system carries the Energy Star rating.AHRI#1499 .dO1 I 1.054i?) Air Handler Ruud 1.5 ton 14.5 seer straight cool air handler RH 1 P series. Condensing unit Ruud 1.5 ton 14.5 seer straight cool condensing unit RA1418 series. Thermostat Digital Thermostat Permit Paper work for City or County(included in price) g 135.00 135.00 Option Option A-Florida is number one in lightening strikes. f /__'�QJl Protect your investment with a surge protector-add !'! 'gDLIC I lb,12' $180.00 to the price of estimate for this option. Option Option B-This is a micro filtration system with UV lighting to help kill air-born pathogens-if you would like this option please add$475.00. We are State Certified and Workers Comp coverage on all employees! Ci Total 3 Q ! d • Signature Phone# Fax# _ 321-639-9205 321-639-9465 Page 1 ru.P/ CERTIFIED' www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number:201165380 Date:04-16-2019 Model Status:Active Old AHRI Reference Number:7490727 AHRI Type:RCU-A-CB Outdoor Unit Brand Name:RUUD Outdoor Unit Model Number (Condenser or Single Package):RA1418AJ1 Indoor Unit Model Number(Evaporator and/or Air Handler):RH1P1817STAN Region: Southeast and North(AL,AR, DC,DE, FL,GA,HI,KY,LA,MD,MS,NC,OK,SC,TN,TX,VA,AK,CO,CT,ID,IL, IA, IN, KS, MA,ME,MI,MN,MO,MT,ND,NE,NH, NJ, NY,01-I,OR,PA,RI,SD,UT,VT,WA,WV,WI,WY,U.S. Territories) Region Note: Central air conditioners manufactured prior to January 1,2015 are eligible to be installed in all regions until June 30,2016.Beginning July 1,2016 central air conditioners can only be installed in region(s)for which they meet the regional efficiency requirement. The manufacturer of this RUUD product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of ANSI/AHRI 210/240 with Addenda 1 and 2,Performance Rating of Unitary Air-Conditioning&Air-Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored,independent,third party testing: Cooling Capacity(A2)-Single or High Stage(95F),btuh: 17900 SEER: 14.50 EER(A2)-Single or High Stage(95F) : 12.00 t"Active"Model Status are those that an AHRI Certification Program Participant Is currently producing AND selling or offering for sale;OR new models that are being marketed but are not yet being produced."Production Stopped'Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re-rate. The new published rating is shown along with the previous(i.e.WAS)rating. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s).or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS MiR1 This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,In whole or in part,be reproduced;copied;disseminated: • entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, personal and confidential reference. AIR-CONDITIONING,HEATING. CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on'Verify Certificate'link we make lite better" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right. ©2019Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 131999210618097515