Loading...
HomeMy WebLinkAboutBLDG PERMIT #7714 (Fire Alarm Upgrade) CITY OF CAPE CANAVERAL DOCUMENT COVER SHEET c_641( (1\j- Box #: 2 2513 ( 7S Item #9 —7,80 Columbia Dr.; Permit #7714 (31) 8 '/2 x 11 pgs. & .6 large format plans (Fire) UPON RETURN OF PAPER ORIGINALS FROM MCCI, add to file name: CITY OF CAPE CANAVERAL DOCUMENT COVER SHEET Boz #: 2 Item #9 — 280 Columbia Dr.; Permit #7714 (31) 8 x 11 pgs. & 6 large format plans (Fire) UPON RETURN OF PAPER ORIGINALS FROM MCCI, add to file name: e1Date.�!;%!��' CITY OF CAPE CANAVERAL Tracking # �a — /f 3�e.,7 �,ED , w BUILDING PERMIT APPLICATION Permit # 7 7 1 4 NOV 1 J 2010 (321) 868-1222 City of Cape Can2vera1 Building Department 7510 N. Atlantic Ave. Cape Canaveral, FL 32920 You may download this application: www.cityofcapecanaveral.org. Yop may fax to: (321) 868-1247. All applications must include the backside of this form. Important: Please complete the checklist on the back of this form and provide other documentation as indicated on the checklist. A copy of contract may be required. Application packages will not be accepted unless complete. APPLICANT WILL BE CALLED WHEN PERMIT IS READY. (Contractor/Owner-Builder is required to sign for the building permit, unless indicated otherwise by affidavit LD. may be required) Address of Job Site:1) �L� a� ��' R. 3 -C7 Zoning classification: Flood Zone: Legal description of pro: TWN: G:3 —1 SEC: % SLJBD: BLK: LOT: PB: PG: Property o� Owner Name: CAI l Malt � �' « 1 l rJ .- Phone: Address: VD bayryrr, t ISL . Fee Simple Titleholder's N e (if otter than owner): ° �-t r _ Address: Bonding Company.N • Address: Mortgage Lender. Address: q Type of Permit Brief description of work: Const. Type (IA, VB, etc) Doc- upancy Group (B,R1, etc.) FPL lines currently available to serve this property? Yes/No City Sewer available to serve this property? Yes/No Building # of dries # of dam- rum units # of bed- rooms # of water closets Valuation of work (copy of Contract Requind) Electrical Commercial Primary Contractor Name: _ ; _Ai :I ,t A Name of Company. +116,4_? . _�' t i , ' i ., _1 Plumbing • e State License No.: t- ;eDe,D ob A_ Phone (office), 321.'! • l o f oPhone (cell/pager.): 32) • 9-!6 'p Fax .7 ; . ' 1 --t . Mechanical Electrical Contractor Name: SFR Name of Company. X Other (� f !/LP . / ria l b ---k. __- 21 tar k)la t a Fink_ dost I, iren, o 1 kt i U ! V Type of Building (please indicate as applicable) Square Feet under roof Const. Type (IA, VB, etc) Doc- upancy Group (B,R1, etc.) FPL lines currently available to serve this property? Yes/No City Sewer available to serve this property? Yes/No Will this structure have built -hi gas appliances? Yes/No # of dries # of dam- rum units # of bed- rooms # of water closets Valuation of work (copy of Contract Requind) Commercial Primary Contractor Name: _ ; _Ai :I ,t A Name of Company. +116,4_? . _�' t i , ' i ., _1 Address: �-D Any- Ili `r —L S Z e State License No.: t- ;eDe,D ob A_ Phone (office), 321.'! • l o f oPhone (cell/pager.): 32) • 9-!6 'p Fax .7 ; . ' 1 --t . $ Electrical Contractor Name: SFR Name of Company. Address: State License No.: Phone (office): Phone (cell/pager.): Fax: $ Townhouse Address: State License No.: Phone (office): Phone (cell/pager.): Fax: $ Apartment Mechanical Contractor Name: _C-•--• Name of Company Address: State License No.: Phone (office): $ Fax: Condominium Specialty/Other Contractor Name: it-- Name of Company Address: $ R Other Phone (cell/pager.): Fax: $ `76u('i d:'ii> Architect/Engineer Name: it 1 ^ Name of Company. - Address: • State License No.: Phone (office): Phone (cell/pager.): Fax: Primary Contractor Name: _ ; _Ai :I ,t A Name of Company. +116,4_? . _�' t i , ' i ., _1 Address: �-D Any- Ili `r —L S Z e State License No.: t- ;eDe,D ob A_ Phone (office), 321.'! • l o f oPhone (cell/pager.): 32) • 9-!6 'p Fax .7 ; . ' 1 --t . Electrical Contractor Name: Name of Company. Address: State License No.: Phone (office): Phone (cell/pager.): Fax: Plumbing Contractor Name: /Z Name of Company Address: State License No.: Phone (office): Phone (cell/pager.): Fax: Mechanical Contractor Name: _C-•--• Name of Company Address: State License No.: Phone (office): Phone (cell/pager.): Fax: Specialty/Other Contractor Name: it-- Name of Company Address: State License No.: Phone (office): Phone (cell/pager.): Fax: Pcrs:+i .ipplicakiun Kit. !r.iv lo. 2010 t J Building Permit Application Checklist Notes Completed Permit Application Current code edition: FL Bldg. Code 2007 (as revised) Current survey showing all proposed construction and landscaping Check with Bldg. Dept for setbacks Notarized signature — Owner/Builder Affidavit If owner is acting as contractor Sewer Impact Fee receipt May be deferred until C.O. Unless job is remodeling County Impact Fee receipt May be deferred until C.O. Capital Expansion Impact Fee receipt Maybe deferred until C.O. Sidewalk Impact Fee receipt If sidewalk exists on lot Recorded Warranty Deed / Proof of Ownership Copy of Recorded Notice of Commencement (over $2,500) Over $7,500 for Mechanical change out Current Cert. Of Liability Ins./Worker's Comp. Policy / Exemption Record will be kept on file after initial submittal Community Appearance Board Approval For all work visible from Public Right -Of -Way Planning and Zoning Board Site Plan Approval For all new construction of four units or more Concurrency Forms For all new construction not part of approved site plan Primary Contractor's State License Record will be kept on file after initial submittal Subcontractor's State License Authorizations: Record will be kept on file after initial submittal Notify Building Department of contractor changes Plumbing Contractor Plumbing Contractor Electrical Contractor Electrical Contractor Mechanical Contractor Mechanical Contractor Roofing Contractor Roofing Contractor Swimming Pool Contractor Swimming Pool Contractor _. Gas Contractor Gas Contractor Specialty/Other Contractor Specialty/Other Contractor Construction Drawings: Per F.B.C. 104 Three sets of sealed construction drawings Per F.B.C. 104 Truss layout and reaction summary Cut sheets and shop drawings will be needed at time of insp. Electrical Load Calculations Plans must indicate person responsible for calculations Electrical Riser All new service must be located underground Plumbing Riser _ Plans must indicate person responsible for design A/C layout - Plans must indicate person responsible for design Two sets of Energy Calculations Plans must indicate person responsible for calculations Lot Drainage Survey Four sets of Fire Suppression/Sprinkler/Alarm specifications Requires Fire Dept approval prior to issuance of permit Pool Barrier Requirement Form (signed) Pool permits will not be issued without barrier Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. The•Building Code in effect at the time of this application is the Florida Building Code 2007 Edition. I understand that all permits require inspections as indicated. This permit application is valid for six months from date of submission. By signing, applicant affirms that all above is true and correct and that he/she is an authorized agent of the Contractor/Owner and has the authority to apply for this permit. Applicant's Name.&s Date: ill(ol0 Applicant's Signatures J�,sol Site Address: ga0 U t . FL For Notary use only: State of F1ori�ai county of yard Sworn and subscribed before me this/0 day of 1 , 20 lc) , by who produced identification: _� is personally known to me. NOTARY PUBLIC -STATE OF FLORIDA Beverly Paxton Commission # DD 663224 ••.,,,,,,,.� Expires: JUNE 01, 2011 BONDED MU ATLANTIC ; QNI;IINNG CO., INC. (;:-i31,ig.Ckpl.Fcrt»~ €3uiikiit ?ctntut Applicatio�u Ruv. Deczs�abcr , I. _uti4 Seal: or STS :41 Printed namplicant Si - - Notary Public At large This form may be duplicated. Address: 2 3co BUILDING PERMIT FEES: wee t3 to 9. Building Permit per square footage. - 7 7 1 4 Total Sq. Ft. (Living Area): Total Sq. Ft. (Enclosed Area): Building Permit based on valuation. Total Sq. �Ft..(Living Area): lsd-z 7,5: 1 Total Sq. Ft. (Enclosed Area): /or,.. Building Permit miscellaneous. Total Sq. Ft. (Living Area): Total Sq. Ft. (Enclosed Area): Electrical Plumbing Mechanical 3uilding Permit Plan Check Fee ire Dept Plan Check Fee TO. Up rt/4' ladon—Trust-Pand:-...„511.footage Zoncurrency Management Fee .7apital Expansion Fee 37©'°Q sp Total Building Permit Fees• i ;EWER PERMIT FEES: Sewer Impact Fee Sewer Tap Fee Total Sewer Permit Fees By: fZI Date: 7/1,) CANAVERAL FIRE RESCUE Serving the city- of Cape Canaveral & Canaveral Port Authority Plan Review To: Building Department Joy Lombardi From: John J. Cunningham, Fire Marsha Re: Colonial House 230 Columbia Dr. Fire Alarm Replacement 7714 Date: 12-16.82.010 We have revi red h plans and have the following comment 1. This project will be done in phases. Phase lhas been approved with additional phases starting with in 1year of this permit. A permit will be required with each additional phase. Fire Alarm Devices: $165.00 Engineer fee: $ 100.00 Plan Review F'e: Station #1: 190 Jackson Avenue • Cape Canaveral, Florida 32920 • (321) 783-4777 • Fax: (321) 783-5398 Station #2: 8970 Columbia Road • Cape Canaveral, Florida 32920 • (321) 783-4424 • Fax: (321) 783-4887 www.ccvfd.org City of Cape Canaveral Inter -Office Transmittal To: Johnny Cunningham From: Joy Lombardi, Building Department Re: 230 Columbia Dr. — Fire Alarm — Colonial House We Transmit: ® Herewith THE FOLLOWING: Plans O Prints 0 In accordance with your request Specifications 0 Shop Drawings 0 Copy of Letter ❑ Information ❑ Other These are transmitted for: ❑ Permit Issue ❑ Approval Review & Comment 0 Record ❑ Use 0 Information 0 Distribution Copies Date Description 4 11/19/10 Fire Alarm Plans Remarks: Copies to: File r By: Space Coast Fire and Safety, Inc. (Your Safety Is Our Business 420 Manor Drive Merritt Island Fl. 32952 www.spacecoastsafety.com John The Colonial House 230 Columbia Ave Cape Canaveral FL 32920 Phone: 321-806-8599 Fax: 321-452-2376 SUBJECT: Fire Alarm System Upgrade REFERENCE: The Colonial House Condo January 18, 2010 revised August 30, 2010 This quote is valid for 30 days e MILL A., 6,1+ - 1 -zoo Space Coast Fire 8s Safety Inc.'s Alarm Services Division Will provide and install the Fire Alarm System as detailed below; SECTION 1.0 SYSTEM DESCRIPTION / SCOPE OF WORK SYSTEM DESCRIPTION: We propose to expand the existing Addressable Fire Alarm (Bosch D7024). To bring the condo up to current fire code. Includes specified Devices, cabling, conduit, boxes and fire stopping of any penetration made by SCFS and a 110VAC. CAD drawings shall be created based on existing blueprints provided by customer. SCOPE OP WORK: This proposal includes all material as detailed below, electrical installation, device installation, programming, check out and training to provide a complete operating Fire Alarm System. Appropriate documentation will be provided to the customer and training on the operation of the system will be provided as required. Install/reuse conduit in hallway for smoke detection in all common and storage areas. Penetrate each unit above kitchen to install mini sounders per NFPA 72. Replace all existing wire and devices, reuse existing raceway where possible. Add pull stations at the front lobby door and the center 1st floor stairwell exit. Relocate pull stations on the 1st floor east and west end of hallway 25' to exit door. Add horn/strobe in the lst floor office Toll Free: (866) Off -Fire Ph: (321) 783-1040 Fax: (321) 783-1516 Space Coast Fire and Safety, Inc. (Your Safety Is Our Business 420 Manor Drive Merritt Island Fl. 32952 www.spacecoastsafety.com ELECTRICAL: Provide and install boxes for alarm devices in units. Supply power to new FAPB from existing house panel. Run surface conduit. Utilizing existing raceway for new wire and devices Penetrate existing floor penetrations. Any holes cut shall have a blank plate to cover them. If they are larger then 2" X 4" do to any unforeseen issues, patching shall be done by others SECTION 3.0 BILL OF MATERIAL & SYSTEM PRICING Fire Alarm Control Panel NAC Power Supply 1 Fire Alarm Annunciator 1 Wall Mount Horn Strobes (Red) 18 Fire Alarm Smoke Detector 47 Ceiling Mount Horn Strobes (Red) Fire Alarm Heat Detector Wall Mount Strobe (Red) Fire Alarm Pull Station 12 Ceiling Mount Strobes (Red) Single Input Module Apartment Mini Horns (White) 56 Dual Input Module WP Wall Mount Strobe (Red) Single Output Module WP Strobe Back Box (Red) Magnetic Door Holder Voice Evacuation Panel Beam Smoke Detector Total Wattage 25, 50, 100, 200 Conventional Duct Smoke Detector Remote Microphone Addressable Duct Smoke Detector Speaker Circuit Zone Splitter Water Flow Connection Wall Mount Speaker Strobes (White) Tamper Switch Connection Ceiling Mount Speaker Strobes (White) Toll Free: (866) Off -Fire Ph: (321) 783-1040 Fax: (321) 783-1516 • • Space Coast Fire and Safety, Inc. (Your Sa. Safety Is Our Business 420 Manor Drive Merritt Island Fl. 32952 www.spacecoastsafety.com BASE PRICING Phase 1. Replace obsolete FACP and tie all existing zones/NACs to the D7024. $ 7,500.00 Design 2 weeks from award Permitting depends on AHJ Installation Begins 1-10 days after permit is issued Installation Complete 1 week Programming, Check Out and Training Day of final inspection Complete • ase Bring complete building up to current fire code. Mini horns in all units, smokes in corridors and pull stations at every exit. Includes replacement of all existing wire with new $ 30,500.00 Installation Complete 5 weeks Programming, Check Out and Training Day of final inspection Complete Estimated time in units 2 hours each for electrical work 1 hour each for wire/device installation Lease programs are available. PAYMENT TERMS 20% to start design and permitting Bi -weekly progress payments Net 15. SECTION 4.0 EXCEPTIONS and CLARIFICATIONS 1. This proposal is void if not accepted in writing within thirty (30) days of this date. 2. All work will be performed during normal working hours and days (M -F 8:O0am - 5:OOpm). No provision has been made for overtime, weekend or holiday work. 3. Permit fees are not included 4. Sales taxes and freight are included. 5. Waste and disposal not included 6. Re -use existing raceway for existing exterior devices 7. Patching of drywall and/or concrete not included in base bid 8. Drywall rough patch 49.00 each(doesn't include texture, popcorn or paint) 9. Final Inspection with Fire Marshal 10. Replace all wiring with new FPLR/THHN wire Toll Free: (866) Off -Fire Ph: (321) 783-1040 Fax: (321) 783-1516 Space Coast Fire and Safety, Inc. 'Your Sa, Safety Is Our Business 420 Manor Drive Merritt Island Fl. 32952 www.spacecoastsafety.com 11. Fire Panel room may need to be air conditioned if humidity is 85% or higher. 12. Space Coast Fire would prefer an owner/owners representative be present while working in each condominium unit. 13. Does not include any additional requirements by the AHJ SECTION 5.0 WARRANTIES We guarantee our work to be free of defects for one year, during which repairs of defective workmanship and/or materials will be made at no cost. This warranty excludes Act of God, re -used products, re -used penetrations, items furnished by others, unauthorized service or negligent care. SCFS will extend the warranty on the installation for an additional year if we are the sole service and monitoring contractor. SECTION 6.0 MONITORING We will set up Fire Alarm Monitoring for the building. Monitoring quote is for twelve month (12) of service at $32.00 per month per building. This quote includes inter office/site programming and set-up. This will be billed quarterly, in advance. This price will be guaranteed for 2 years of service. Monitoring can be terminated after the first year with a (30) thirty day written notice. Sincerely, Space Coast Fire & Safety Inc. Jason Spina Manager ACCEPTANCE OF PROPOSAL The above prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payments will be made as noted above. Arw Signa Print „A czylAp(eic 'T1(16trz cx-LL-) 14ack to uph d ,0� Postion li st - 4D zc.� 1 1 Toll Free: (866) Off -Fire Ph: (321) 783-1040 Fax: (321) 783-1516 r Fire Alarm Systems,I D7024 -EXP Fire A lai'm Control Panels D7024 -EXP Fire Alarm Control Panels The D7024 -EXP Fire Alarm Control Panels (FACPs) can be used in commercial and public building applications such as schools, universities, manufacturing plants, and health care facilities. The D7024 -EXP FACPs support four on -board initiating zones that can be expanded to eight using the D7034. Each initiating loop supports two -wire and four -wire detectors configurable as Class A, Style D (with D7014) or Class B, Style B loops. Each zone can support up to 20 two -wire detectors, or any number of four -wire detectors depending on available power. Each FACP has a built-in digital fire alarm communicator transmitter (DACT). Enhance the D7024 -EXP conventional system features when running version 2.02 or higher firmware by adding a D7039 Multiplex Expansion Module. Adding a D7039 Multiplex Expansion Module to the D7024 -EXP turns the conventional FACP into an addressable FACP. The D7039 adds up to 247 addressable points to the base system and adds an additional 400 events to the history buffer for a total of 499 events. The D7039 also increases the number of programmable relay outputs from 18 to 58 and allows up to 100 system users (an addition of 84 PINs to the base system). ► Four detector zones (expandable to eight); up to 20 two -wire smoke detectors per zone ► Built-in DACT ► Two notification appliance circuits (NACs) on board with an internal 24 VFWR, 4 A NAC power supply ► Easily converts to addressable with the addition of a D7039 Multiplex Expansion Module ► Programmable through front panel interface, remote D7033 Liquid -crystal Display (LCD) Keypads, or remote programming software (RPS) f=unctions' Notification Appliance Circuits (NACs) Two on -board Class B, Style Y or Class A, Style Z (with D7015) NACs provide up to 4 A of 24 VFWR power to operate horns, strobes, bells, and other notification appliances. Each NAC can be programmed to provide Temporal Code 3, steady, pulsed, and synchronized output for Wheelock"' and Gentex"' notification appliances. User Interface A viewing port in the keyed control panel enclosure door shows the system status light -emitting diodes (LEDs) and LCD display while maintaining system keypad security. Unlocking the enclosure door provides access to the system controls for silencing off -normal conditions, zone bypassing, detector resetting, testing, other fire functions, and programming. These functions are also available on all D7033 LCD Keypads connected to the system. All D7036 LCD Annunciators provide custom text annunciation on a 32 -character, backlit, two-line LCD display. All system keypads and annunciators have built-in sounders. Back -light intensity and sounder volume are programmable. www. boschsecu rity.com 1 2 1 D7024 -EXP Fire Alarm Control Panels Personal Identification Numbers (PINs) There are 16 PINs available for accessing system control. Assign each number an authority level to limit access to the system control functions. Note The number of PINs increases to 100 with the addition of a D7039 Multiplex Expansion Module. History Buffer The system stores events in a 99 -event history buffer. Note The number of events that can be stored in the history buffer increases to 499 with the addition of a D7039 Multiplex Expansion Module. Central Station Reporting The D7024 -EXP FACPs send reports to two telephone numbers with full single, double, and backup reporting. They communicate in BFSK, SIA, Contact ID, Modem 111a2, and 4/2 and 3/1 Tone Bursts. Dirty Smoke Detector Monitoring All on -board zones and D7034 zones are continuously monitored for smoke detectors signaling a dirty condition using the Bosch Chamber Check® feature and CleanMe® protocol. If a detector's smoke chamber is dirty, the detector sends a CleanMe signal on the two -wire loop or a dirty detector signal on the addressable loop. The control panel annunciates that there is a dirty detector on the loop or the address. The Chamber Check feature signals a dirty smoke chamber using the LED on the detector head. Accessories The D7024 -EXP enclosure has space for additional accessory modules and two D1218 (18 Ah) batteries or two D126 (7 Ah) batteries. Installatlo nfiauration Na Compatible Products The following products are compatible with the D7024 -EXP FACPs: Category Product ID Product Description Batteries and D126 12 V, 7 Ah battery Power Supplies D1218 12 V,18 Ah battery D7038 Remote NAC power supply Detectors For two -wire detectors, refer to D7022 -D7024 Com- patibility List Technogram (P/N: 34/145) Keypads and D7030X Eight -point LED annunciator Annunciators (eight red) D7030X-S2 Eight -point LED annunciator (two yellow, six red) D7030X-S8 Eight -point LED annunciator (eight yellow) Category Product ID D7032 D7033 D7036 Modules D132B D184A D185 D275 D7014 D7015 D7031 D7034 D7035 D7035B D7039 D7039R Product Description Eight -zone LED annunciator expander (eight red) LCD fire system keypad LCD annunciator Smoke detector reversing relay mod- ule Auxiliary local energy interface kit Reversing polarity module EOL power supervision module Zone converter module Class B to Class A NAC converter Silence reset module Four -point expander Octal relay module Octal relay module in box Multiplex expansion module Multiplex expansion module retrofitkit NAC Devices Refer to D7024 NAC Compatibility List Technogram (P/ N: 34950) The following additional product is compatible with the D7024 -EXP Addressable FACPs: Category Modules Product ID D7042 D7042B D7044 D7044M D7048 D7048B D7052 D7053 Pull Stations FMM-7045 FMM-7045-D Product Description Multiplex eight -input remote module Multiplex eight -input remote module in box Multiplex single -input module Mini multiplex single -input module Multiplex octal driver Multiplex octal driver in box Multiplex dual -input module Multiplex input-output module Single-action manual station Double -action manual station D7024-EXPFire Alarm Control Panels j 3 Quant. Component 1 D7024 -EXP board in a static -resistant bag 1 Enclosure (P/N: 30897) 1 Lock set with 2 keys (P/N: 24065) 1 Transformer (P/N: 38602) 6 2.21 k0 end -of -line (EOL) resistors (P/N: 25899 or 4998113202) 1 Hardware pack 1 Literature pack Note For the D7024 -EXP to be addressable, a D7039 Multiplex Expansion Module must be installed. The D7039 is purchased separately. Technical:S Environmental Considerations Temperature (operating): 0°C to +49*C Mechanical Properties Color: Red Dimensions (H x W x D): 52.8 cm x 38.1 cm x 10.9 cm Material: Cold -rolled steel Base: 1.2 mm Cover: 1.1 mm NAC: 24 VFWR nominal, 4 A maximum On -board Relays: Two Form C contacts rated at 5 A, 28 VDC Off -board Relays: Power Requirements Current (alarm): Current (standby): Up to two D7035 Octal Relay Modules each provid- ing eight Form C relay outputs; contacts rated at 5 A, 28 VDC In an addressable system, up to 20 D7053 Multiplex Input -Output Modules per bus for a total of 40 380 mA 200 mA Power (primary) Sensor Circuits Current 220 VAC, 1.5 A maximum, 50 Hz 44 mA maximum per loop Line resistance: 1500 Voltage: 24 VDC nominal Trademarks Chamber Check® is a registered trademark of Bosch Security Systems, Inc. in the United States. CleanMe is a registered trademark of GE Interlogix in the United States and/ or other countries. Wheelock' is a trademark of Wheelock, Inc. Gentee is a trademark of Gentex Corporation. Orcler'snglnfo'iriatiofi D7024 -EXP FACP for Export Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone D7024-EXPLT FACP for Export without D7024-EXPLT Enclosure and Transformer Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone D7024 -EXP Accessories KEY -625 Replacement Key Replacement key KEY -625 www.boschsecurity.com t 41D702/4. -EXP Fire Alarm Control Panels Americas, Bosch Security Systems, Inc 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 sewNty.sales@us.bosch.com www.boschsecurlty.us Europe, Middle East, African Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax +31 40 2577 330 emea.securitysystems@bosch.com www. boschsecurlty.com © Bosch Security Systems Inc 2010 I Data subject to change without notice 73642949899 1 Cur: en -US, V6, 4 Jul 2010 Asla-PaciBa Represented by Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6258 5511 Fax: +65 6571 2698 apr.securitysystems@bosch.com www.boschsecurlty.com FIRE SYSTEM ACCESSORY; SILENT KNIGHT by Honeywell Model 5495 Distributed Power Module In an emergency, you need maximum power The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®, AMSECO®, Wheelock and Faraday — what you need to drive power- hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1-800-328-0103. Model 5495 Distributed Power Module The 5495 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls such as the Silent Knight Model 5208 Fire Control /Communicator. The 5495 is the cost- effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5495 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. Features • UL Listed for 6 amps of notification power • Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems • Dip switches allow for easy reconfiguration • 24 VDC filtered output voltage • Four power -limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B • Additional continuous auxiliary output • 3 amps per output circuit • 2 inputs; 2 Class B or 2 Class A • Ground fault detector/indicator • Independent trouble relay • AC loss delay option shuts off power to non-essential high -current accessories like magnetic door holders • Built-in synchronization for appliances from System Sensor®,Gentex®, AMSECO®, Wheelock and Faraday • Stand alone operation • Lightweight design adds to ease of installation and reduces shipping costs • Operates with most polarized, UL Listed notification devices • ANSI Cadence pattern output capability built-in Connection to Local Fire Control The 5495 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the inputs on the 5495. The control panel's notification circuit end -of -line resistor is also connected across two terminals on the 5495, which provides supervision between the 5495 and the fire control panel. Polarized audible and/or visual notification devices are then connected to the 5495 signal circuits using the 4.7kL2 end -of -line resistors provided. Since the 5495 draws very little power from the control, it is possible to connect one 5495 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. Model 5495 Distributed Power Module Approvals • UL Listed • MEA 429-92-E Vol XII • CSFM 7300-0559:123 • NFPA 72 FIREASY$TEM ACCESSORY Model 5495 Distributed Power Module Model 5495 Block Diagram Signal Circuit Output Signal Circuit Output Signal 1 Input Signal 2 Input (Optional) 120 VAC Local Fire Control Distributed Power Module 5495 Trouble Output (Alternative to notification circuit trouble.) Signal 1 Signal 2 Signal 3 Signal 4 Aux. Power Supervision The 5495 supervises a variety of functions including: • Low AC power • Low battery condition • Earth ground fault • Auxiliary output power limit condition • EOL supervision trouble or power limited condition at an output When a trouble condition occurs, the 5495 creates a trouble condition on the host control signal circuits to which it is connected. the 5495 still maintains the ability to be activated by the host control. In addition, the 5495 provides a Form C trouble relay output as an altemative to using the notification circuit trouble. Electrical Specification AC input: 120 VAC at 2 amps Output: 24 VDC at 6 amps Current: Standby Alarm Auxiliary power circuit: Notification circuits: Output configuration: Amps per output circuit: Notification circuit output: 75 mA 205 mA 1 4 2 Class A (Style Z) 4 Class B (Style Y) (1 Class A & 2 Class B) 3.0 (6.0 amps total) 20.4 to 27.3 VDC @ 3.0 amps each, 4.7 Icff EOL resistor required on each Class B circuit No. of inputs 2 Input configuration: 2 Class B or 2 Class A Input voltage range: 9 - 32 VDC Battery charging capacity: 35.0 AH Ambient temp.: 32° to 120° F (0° to 49° C) Mechanical Dimensions: 12.25" W x 16" H x 3" D (30.88 cm W x 40.64 cm H x 7.62 D cm) Indicator Lights AC power on : Green Battery trouble: Yellow Ground fault: Yellow Aux trouble: Yellow Output troubles (1-4): Yellow Ordering Information 5495 Distributed Power Module SILENT KNIGHT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-7161 Phone: (800) 328-0103, Fax: (203) 4847118. www.silentknight.com MADE IN AMERICA FORM# 350395 Rev D © 2010 Honeywell International Inc. Y Fire. Alarm Systems 1 D7033 LCD Keypad D7033 LCD Keypad The D7033 LCD Keypad combines remote annunciator and controller functions for fire alarm systems controlled by the D7024 Fire Alarm Control Panel (FACP). It operates identically to the user interface on the D7024 FACP. You can connect up to four D7033 keypads to a D7024. Also use it to program the D9068 Fire Digital Alarm Communicator Transmitter (DACT). The D7033 allows remotely starting local system tests, system programming, system control, and viewing the system's event log. Passcode protect access to system functions allowing installation in areas open to the general public. The two-line, 32 -character LCD (liquid -crystal display) annunciates system status and events. The top line provides general system status information, while the bottom line identifies specific devices or procedures. An internal sounder signals alarm and trouble conditions and annunciates keystrokes during programming and control procedures. Four status LEDs indicate power, alarm, trouble, and silenced conditions. A pull-out slide with operating instructions fits behind the mounting base. ► Compatible with the D7024 FACP ► Two-line, 32 -character, alphanumeric LCD display ► Status LEDs identify alarm, trouble, power, and silenced conditions ► Address setting by jumper ► Remotely control system including commands and programming ► Passcode protection controls system access ► Low -profile design Certifications and A Region Certification ovals, USA UL UOXX: Control Unit Accessories, System (UL864, 9th edition) FM CSFM NYC -MEA 7165-1615: 147 July 2008 12-92-E, Vol. VII 12-92-E, Vol. VII 12-92-E, Vol. 14 12-92-E, Vol. 14 26-02-E, Vol.11 26-02-E, Vol. II In Natio tfCo fi rati Compatible Products The following products are compatible with the D7033 LCD Keypad: Category Product ID Control Panels D7024 D7024EXP Keypads and D7030X Annunciators D7030XS2 D7030XS8 Transmission D9068 Devices 0 Dotes Product Description FACP FACP for export LED annunciator LED annunciator LED annunciator Fire DACT www.boschsecurity.com 5 5 2i D7033 LCD Keypad Mounting Mount the D7033 on a single -gang or four -inch square back box. Wiring Guidelines • Do not share keypad wiring with multiplex, telephone, or NAC wiring. • Use a minimum of 22 AWG (0.8 mm) four -wire cable; but do not use twisted pair or shielded cable. Note A minimum of 18 AWG (1.2 mm) cable is needed for NEC-NFPA-72. • Do not exceed 1000 ft (305 m) between the control panel and the remote keypads. • Do not exceed the total amount of keypad wiring permitted per system which is limited to a maximum of 4000 ft (1219 m). Number of keypads Do not connect more than four keypads. Place up to two keypads along any single 1000 ft (305 m) run of 22 AWG (0.8 mm) wire. Three keypads can be used on any single 1000 ft (305 m) run of 18 AWG (1.2 mm) wire. Teiihnica l Sp i icat ons Environmental Considerations Relative Humidity: 5% to 85%at+86°F (+30°C), non -condensing Temperature (Operating): +32°F to +122°F (0°C to +50°C) Mechanical Properties Dimensions (H xW x D): 4.6 in. x 6.3 in. x 1.2 in. (12cmx16cmx3cm) Power Requirements Current (alarm): 100 mA Current (standby): 80 mA Voltage (operating): 12 VDC nominal OrdE nfolrmation D7033 LCD Keypad Combines remote annunciator and controller functions for fire alarm systems controlled by the 07024 Fire Alarm Control Panel Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: *1 800 289 0096 Fax: +1 585 223 9180 security.salesgpus.bosch.com www.boschsecurity.us D7033 Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emeasecurftysystemsobosch.com www.boschsecurtty.com CO Bosch Security Systems Inc. 20101 Data subject to change without notice 713003623791 Cur: en -US, V8, 4 Jul 2010 Asia•Pm:Hfa Represented by Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6258 5511 Fax: +65 6571 2698 apr.securitysystems®bosch.com www.boschsecurlty.com Fl re•lrre®Akarms A PIT1wir COMPANY July 29, 1999 BG -1 0 Series Manual Fire Alarm Stations Section: Conventional Initiating Devices F-100 GENERAL The Fire•Lite BG -10 Series Manual Fire Alarm Stations provide dual -action, normally -open contact alarm initiating points for use with UL listed fire alarm control panels. The BG -10 Series features non -coded, dual -action operation. FEATURES • Within ADA 5 Ib. pull force when used without break -tube (models manufactured after 10-1-96, identified by an under station spring). • Impact -resistant, durable LEXAN® (or polycarbonate equivalent) housing. • Back plate made of 16 gauge steel. • Highly visible. • Easily operated. • Attractive shape with textured finish. • Semi -flush or surface mounting. • Operates with or without a break tube. • Handle latches in down position to clearly indicate that the station has been operated. • Optional lock with standard Fire•Lite key. • Optional N.O. contact for auxiliary functions. • Optional pre -signal circuit. • Spanish (FUEGO) version available. APPLICATIONS The BG -10 Series manual fire alarm stations are intended for use as fire alarm initiating devices, with any fire alarm initiating circuit to be operated by a contact closure. The stations are for indoor or outdoor (BG-10WP) use and should be installed in compliance with applicable NFPA standards, local building codes, and plans and specifications. INSTALLATION The BG -10 Series manual fire alarm stations mount to stan- dard single -gang electrical boxes. A terminal block with screws allows for fast and easy wiring. OPERATION Pulling the handle down causes the BG -10 to latch in the down position and to close the normally -open switch. The handle is restored manually by unscrewing the allen-head screw so the top of the case can pivot forward, allowing the spring-loaded handle to return to Its normal position. The case can then be pivoted back to its normal position and secured with the allen-head screw. The BG -10L utilizes a mechanical key instead of the alien - head screw. The BG-10P/T has a normally -open auxiliary switch which is closed by rotating a key clockwise. (The key is non -remov- able in this position.) S711 CS115 ADA California State Fire Marshal 7150-0075:103 0G5A5AY SPECIFICATIONS Physical: 512o3tl1m.tbl Electrical: Current Capacity: 3 Amps @ 30 ViiMs. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. This document Is not Intended to be used for installation purposes. We try to keep our product Information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite. Phone: (203) 484-7161 FAX: (203) 484-7118 FIf E UTe"ALatrms One Fire -Lite Place, Northford, Connecticut 06472 ISO -9001 Engineering and Manufacturing Quality System Certified to International Standard ISO -9001 Made in the U.S.A. DF -51203 — Page 1 of 2 BG -10 SB -10 WP -10 Height 5.500 inches (139.700 mm) 5.500 inches (139.700 mm) 6.000 inches (152.400 mm) Width 4.125 inches (104.775 mm) 4.125 inches (104.775 mm) 4.690 inches (119.126 mm) Depth 1.375 inches (34.925 mm) 1.375 inches (34.925 mm) 2.000 inches (50.800 mm) 512o3tl1m.tbl Electrical: Current Capacity: 3 Amps @ 30 ViiMs. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. This document Is not Intended to be used for installation purposes. We try to keep our product Information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite. Phone: (203) 484-7161 FAX: (203) 484-7118 FIf E UTe"ALatrms One Fire -Lite Place, Northford, Connecticut 06472 ISO -9001 Engineering and Manufacturing Quality System Certified to International Standard ISO -9001 Made in the U.S.A. DF -51203 — Page 1 of 2 Wiring of Standard Unit: BG -10 TO CONTROL PANEL DETECTOR LOOP OUTPUT TO NEXT DEVICE OR E.L.R. Additional Switch Included With Models: BG -1 OA I BG-10LA TO TERMINAL BLOCK FOR N.O. CONTACT FOR AUXILIARY FUNCTIONS Additional Switch (Key -Operated) Included With Models: BG -1 OP BG -10T b TO TERMINAL BLOCK FOR TEST, OR TO PRESIGNAL CIRCUIT (KEY OPERATED) a The BG-10SP PRODUCT LINE INFORMATION Model Description BG -10 Standard unit. Dual action. Works with or without a crush tube. Includes a terminal block with screws for fast and easy wiring. BG -10A Standard unit plus an auxiliary N.O. switch to provide annunciator contacts. BG -10T Standard unit plus key -test feature. BG -10P Standard unit plus N.O. switch for pre - signal operation. BG -10L Standard unit plus key locking feature. BG-10LA Standard unit plus an auxiliary N.O. switch to provide annunciator contacts, plus key locking feature. BG-10WP Standard unit with a weather gasket (BG -10W). Includes appropriate surface backbox (WP -10) for outdoor applications. BG-10SP Spanish version of standard unit. Dual action. Works with or without a crush tube. Includes a terminal block. WP -10 Surface backbox for outdoor applications (used withliintluded with BG-10WP). SB -10 Surface -mount backbox for all BG -10 models. BG -TR Optional trim ring. 51203t1.tb1 ARCHITECTURAL/ENGINEERING SPECIFICATIONS Manual Fire Alarm Stations shall be non -coded, break -tube (or non -crush tube) type, with a key -operated test -reset lock (or Hex reset) in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key (or Hex). An operated station shall automatically condition itself so as to be visually detected, as operated, at a minimum distance of 100 feet (30.48 meters), front or side. Manual Stations shall be constructed of LEXAN® (or polycarbonate equivalent) with clearly visible operating instructions on the front of the stations in raised letters, 1.75 inches (44.45 mm) or larger. Stations shall be suitable for surface mounting on matching backbox, or semi - flush mounting on a standard single -gang box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) dependent on manual station accessibility or per local requirements. Manual Stations shall be Underwriters Laboratories listed. Page 2 of 2 — DF -51203 • • Y • GE Security Overview GE brand 500 Series two- and four -wire conventional photoelectric smoke detectors bring together trusted technology and a full line of features that meet the demands of every type of application. The 500 offers sounders in two- and four -wire applications, specifically to meet residential code requirements. The 500 Series also offers choices for optional auxiliary relays and isolated heat sensors, not available before in the 500 Series. GE is also proud to offer proven technology like CleanMe®, dust compensation, field replaceable optical chambers, and self -diag- nostics. CleanMe® is only available on the 500 2 -wire models and will communicate to the GE FireworX panels when servicing is required. 500 Series detectors work on a light -scattering principle. A pulsed infrared light -emitting diode serves as the light source, and a high- speed photo diode as the sensing element. This design has superior protection against nuisance alarms caused by dust, insects, RF interference, and ambient light. The proprietary optical chamber is field replaceable. In the event of a confirmed alarm the LED will light continuously. The unit indicates trouble by flashing the LED every second. This meets the NFPA 72 field sensitivity testing requirements. Units with built-in 85dBA sounders emit a temporal 3-3-3 tone pattern when in alarm and will emit a steady tone when the input power is reversed. All wiring terminates in clamp -type screw termi- nals. The detectors mount to a standard single -gang electrical box, a four -inch octagonal, four -inch square electrical box, or WIREMOLD No. 5739 fixture box. Smoke Detectors with Auxiliary Functions 500 Series =ire & Life Safety Smoke Detection Standard Features • Remote maintenance (CleanMe®) reporting (2 -wire models) and built-in drift compensation reduces false alarms • Self diagnostics eliminates the need for external meters • Field -replaceable optical chamber makes service fast and simple • Small, low profile design blends with any environment • Optional auxiliary functions include: • Integral sounder • Fixed/Rate-of-Rise heats • Auxiliary relay • Single station smoke with system heat • Built-in power supervision relay Data Sheet FX85001-0606 Issue 1 Not to be used for installation purposes. Page 1 of 2 1 k t Application 500 Series detectors are ideal for both retrofit applications and new installations alike. They are particularly well-suited for installations where detector reliability is essential, but where analog devices may not be appropriate or feasible. With their replaceable optical cham- bers, these detectors are equally well-suited to dusty environments where detectors require frequent cleaning. Mounting and Installation 500N detector bases mount directly to standard single -gang electri- cal boxes, three-inch round, or four -inch octagonal boxes. Detector heads simply twist onto the base. Heads are equipped with a break- away locking tab, which prevents unauthorized removal. Terminals accept 12 to 24 AWC field wiring. Typical Wiring 2 -wire Initiating + Moult _ C Listed Alarm Control Specifications Assembly Optional fixed temperature sensor Diagnostic LED Optional rate -of -rise sensor Dimensions Photoelectric sensor Replaceable optical chamber Detector cap Power Supply 8.5-33VDC (12/24 V operation) polarity sensitive Maximum ripple pk-pk (6/12/24V) 10% (Vpk-pk) Typical average standby current 70 NA Typical alarm current (6/12/24V) up to 60 mA max if not limited by control panel Auxiliary relay contacts 1.0 A @ 30 VDC; Form C Alarm contacts 500 mA @ 36 VDC (resistive) Photoelectric sensitivity 3.1%+0.5-1.0% Operating temperature 32° to 100° F (0° to 37° C) Operating humidity range 0 to 95% non -condensing RFI immunity 20 V/m min; 0-1000 MHz Color White Feld wiring size Detector packaging 12-24 AWG (16-22 recommended) 10 detectors per carton Heat detector specifications Rate -of -Rise: 15° F/min and >105° F (8.3° C/min and >40.6° C) Fixed Threshold: 135° F (57.2° C) UL 2 -wire compatibility identifiers S10A,S11A Drift compensation adjustment 1.0% ft. max Detector head dimensions 5.5Dx2"H(14.0x5cm) Mounting dimensions 5.25" (13.3 cm) diameter; 0.3" (0.8 cm) height Regulations Reset time 1 second min Listings C -UL -US, CSFM, MEA Data Sheet FX85001-0606 Issue 1 Not to be used for installation purposes. Page 2 of 2 Ordering Information Model ! Description Compatibility Alarm Current imAl Reverse polarity MAI 521B 2 -wire, photoelectric, 6-33VDC S09A/S10A 5 min. - 60 max. 521BXT 2 -wire, photoelectric, 6-33VDC, fixed temp and rate -of -rise heat S09A/S10A 5 min. - 60 max. 521NCRXT 2 -wire, photoelectric, 8.5-33VDC, fixed temp and rate -of -rise heat, aux. relay S11A 15 min. - 60 max. 521NCSXT 2 -wire, photoelectric, 8.5-33VDC, fixed temp and rate -of -rise heat, temporal 3 S10A sounder 10 min. - 60 max 10 521NCSRXT 2 -wire, photoelectric, 8.5-33VDC, fixed temp and rate -of -rise heat, aux. relay S11A 15 min. - 60 max 10 temporal 3 sounder 541C 4 -wire, photoelectric, 6-33VDC N/A 541CXT 4 -wire, photoelectric, 6-33VDC, fixed temp and rate -of -rise heat N/A 541NCSRXT 4 -wire, photoelectric, 8.5-33VDC, fixed temp and rate -of -rise heat, aux. relay, N/A temporal 3 sounder 20 20 35 13 541NCSXTE 4 -wire, photoelectric, 8.5-33VDC, fixed temp and rate -of -rise heat, built-in end N/A of line relay, temporal 3 sounder 45 28 541NCSRH 4 -wire, photoelectric, 8.5-33VDC, isolated fixed temp and rate -of -rise heat, aux. N/A relay, temporal 3 sounder, non -latching LED with auto reset 35 13 541NCRXT 4 -wire, photoelectric, 8.5-33VDC, fixed temp and rate -of -rise heat, aux. relay N/A 25 541NCXTE 4 -wire, photoelectric, 8.5-33VDC, fixed temp and rate -of -rise heat, built-in end N/A of line relay 35 541NCSXT 4 -wire, photoelectric, 8.5-33VDC, fixed temp and rote -of -rise heat, temporal 3 N/A 30 13 sounder 548C 4 -wire, photoelectric, 8.5-33VDC, ULC Listed 548CT 4 -wire, photoelectric, heat, 8.5-33VDC, ULC Listed Note: Only 500 Series 2 -wire smoke detectors are CleanMe compatible. is ladd the follawir►g suffixes es 8 6-33VDC operation C E 8.5-33VDC operation End -of -Line relay H R Isolated rate -of -rise and fixed temp sensors Auxiliary relay S 85dBa sounder XT Rate -of -rise and fixed temp sensors 405-05 Polarity reversal module enables sounder interconnection of all 4 -wire smoke detectors, when initiating detector sounds all smokes sound. 401 Test magnet in a plastic shell for pole mounting SM200-12PKG Smoke in a Cant® canned smoke for functional testing SM-ext1L Smoke in a Can!® extension tube 211-10PKG Replacement optical chambers (set of 10) 500PLT-5PKG 6" trim ring for wider coverage area Data Sheet FX85001-0606 Issue 1 Not to be used for Installation purposes. Page 3 of 2 I 1E Security U.S. T 888-GESECURITY F 503-691-7566 Canada T 519 376 2430 F 519 376 7258 Asia T 852 2907 8108 F 852 2142 5063 Latin America T 305 593 4301 F 305 593 4300 www.gesecurity.com/fireworx © 2009 General Electric Company All Rights Reserved imagination at work Data Sheet FX85001-0606 Issue 1 Not to be used for installation purposes. Page 4 of 2 s A A SYSTEM SENSOR° Selectable -Output Horns, Strobes, and Horn Strobes SpectrAlert®Advance selectable -output horns, strobes, and horn strobes are rich with features guaranteed to cut installation times and maximize profits. Features - Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 candela • Field -selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and three volume selections • Universal mounting plate for wall and ceiling units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with existing SpectrAlert products • Compatible with MDL sync module Agency Listings SUMMING USTED S4011 (ch ems, hom strobes, horns) 55512 (strobes) APPROVED 3023572 MEA approved MEA452-05-E 7125-1651186 (Indoor strobes) 7125-1653:188 (horn strobes, chime strobes) 7135-1653,189 (horns, chimes) The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. AH devices feature plug-in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. Furthermore, a universal mounting plate with an onboard shorting spring tests wiring continuity before the device is installed, protecting devices from damage. In addition, field -selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. SpectrAlert Advance Specifications Architect/Engine er-Specifications : General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11 -inch back box, 4 -inch octagon back box, or double -gang back box Two -wire products shall also mount to a single -gang 2 x 4 x 17/8 -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync"Circuit Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 175 volts; 24 -volt -rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15,15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Hom Strobe Combination The hom strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The hom shall have three audibility options and an option to switch between a temporal three -pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder.The hom on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync -Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4116 x 4n/16 x 21/8 -inch back box The module shall also control two Style Y (dass B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Rangel 8 to 175 V (12 V nominal) or 16 to 33 V (24V nominal) Input Terminal Fire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Wall -Mount Dimensions (including lens) 5.6"Lx4.7"Wx 25"D(142 mm Lx 119 mmWx64 mm D) Hom Dimensions 5.6" L x 4.7-W x 1.3"D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Back Box Skirt Dimensions (BBS -2, BBSW-2) 5.9" L x 5.0"W x 2.2"D (151 mm L x 128 mm W x 56 mm D) Ceiling -Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2) 7.1" diameter x 2.2 -high (180 mm diameter x 57 mm high) Wall -Mount Trim Ring Dimensions (sold as a 5 pack) (TR -HS, TRW -HS) 5.7" L x 4.8"W x 0.35"D (145 mm L x 122 mm W x 9 mm D) Ceiling -Mount Trim Ring Dimensions (sold as a 5 pack) (TRC-HS,TRCW-HS) 6.9 -diameter x 035" high (175 mm diameter x 9 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time -varying power source that is used on some power supply and panel outputs. 2. P, 5, PC, and SC products will operate at 12V nominal only for 15 and 15/75 cd. UL Current Draw Data UL MaX,St ,§ a Currenf Draw (mAJIM ' , Candela 8-17.5 Volts 4DillylagHbrtgiirgrIttprAg(MAIBM9111 16-33 Volts 8-17.5 Volts 16-33 Volts DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard Candela Range 15 123 128 66 71 Temporal High 57 55 69 75 15/75 30 75 95 142 NA NA NA 148 NA NA NA 77 81 Temporal Medium 44 49 58 69 94 96 Temporal Low 38 44 44 48 158 153 Non -temporal High 57 56 69 75 181 176 Non -temporal Medium 42 50 60 69 High Candela Range 110 115 135 150 177 185 NA NA NA NA NA NA NA NA NA NA NA 281 251 NA 202 195 Non -temporal Low 41 44 50 50 210 205 Coded High 57 55 69 75 228 207 Coded Medium 44 51 56 69 246 220 Coded Low 40 46 52 50 286 258 ULMax CurrentDraw,(mA,RMS) 2 witg-HorrtStrobe Standard Candela Range (15 115icd) DC Input 8-175 Volts 16-33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High Temporal Medium Temporal Low Non -Temporal High Non -Temporal Medium Non -Temporal Low 137 132 132 141 133 131 147 144 143 152 145 144 79 69 66 91 75 68 90 80 77 100 85 79 107 97 93 116 102 96 176 157 154 176 163 156 194 182 179 201 187 182 212 201 198 221 207 201 218 210 207 229 216 210 FWR Input Temporal High Temporal Medium 136 155 129 152 88 78 97 88 112 168 190 103 160 184 210 218 202 206 Temporal Low Non -Temporal High Non -Temporal Medium Non -Temporal Low 129 142 134 132 151 161 155 154 76 103 85 86 80 112 95 90 101 126 110 105 160 181 166 161 184 203 189 184 194 221 208 202 201 229 216 211 ULMax. Current Draw (n)A RMNS), "2 -Wire Horn Strobe, High cCandela -.Range (135-185 cd) DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High Temporal Medium Temporal Low Non -Temporal High Non -Temporal Medium 245 259 290 297 235 253 288 297 232 251 282 292 255 270 303 309 242 259 293 299 Temporal High Temporal Medium Temporal Low Non -Temporal High Non -Temporal Medium 215 231 258 265 209 224 250 258 207 221 248 256 233 248 275 281 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Horn Tones and Sound Output Data 'Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 1 Temporal High 2 Temporal Medium 3 Temporal Low 4 Non -Temporal High 5 Non -Temporal Medium 6 Non -Temporal Low 7t Coded High 8t Coded Medium 9t Coded Low 8-175 Volts DC FWR 16-33 Volts Reverberant Anechoic 24 -Volt Nominal 78 74 71 82 78 75 82 78 75 78 74 73 82 78 75 82 78 75 DC FWR DC FWR DC FWR 84 84 88 88 99 98 80 80 86 86 96 96 76 76 83 80 94 89 88 88 93 92 100 100 85 85 90 90 98 98 81 81 88 84 96 92 88 88 93 92 101 101 85 85 90 90 97 98 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2 -wire horn strobe. A05-0395-007 • SpectrAlert Advance Dimensions 4.7" •-2S: Wall -mount hom strobes i 5.98" L--5.05"-1le-2.231 p•VI O O p o a e c7 Wall back box skirt c SpectrAlert Advance Ordering Information Model Description Wall Hom Strobes P2R*t 2 -Wire Horn Strobe, Standard cd*, Red P2RH* 2 -Wire Horn Strobe, High cd, Red P2W* 2 -Wire Horn Strobe, Standard cd, White P2WH* 2 -Wire Horn Strobe, High cd, White P4R* 4 -Wire Horn Strobe, Standard cd, Red P4RH 4 -Wire Horn Strobe, High cd, Red P4W 4 -Wire Horn Strobe, Standard cd, White Wall Strobes SR** Strobe, Standard cd, Red SRH** Strobe, High cd, Red SW Strobe, Standard cd, White SWH* Strobe, High cd, White Ceiling Horn Strobes PC2R* 2 -Wire Horn Strobe, Standard cd, Red PC2RH 2 -Wire Horn Strobe, High cd, Red PC2Wt 2-1Nire Horn Strobe, Standard cd, White PC2WH* 2 -Wire Horn Strobe, High cd, White PC4R 4 -Wire Hom Strobe, Standard cd, Red PC4RH 4 -Wire Hom Strobe, High cd, Red PC4W 4 -Wire Horn Strobe, Standard cd, White Ceiling -mount hom strobes Ceiling back box skirt Model Description Ceiling Strobes SCR Strobe, Standard cd, Red SCRH Strobe, High cd, Red SCW Strobe, Standard cd, White SCWH Strobe, High cd, White Homs HR Horn, Red HW Horn, White Accessories BBS -2 Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt, Wall, White BBSC-2 Back Box Skirt, Ceiling, Red BBSCW-2 Back Box Skirt, Ceiling, White TR -HS Trim Ring, Wall, Red TRW -HS Trim Ring, Wall White TRC -HS Trim Ring, Ceiling, Red TRCW-HS Trim Ring, Ceiling, White Notes: * Add°-P°to model number for plain housing (no °FIRE° marking on cover), e.g, P2R-P. t Add°-SP°to model number for °FUEGO° marking on cover, e.g., P2R-SP. #°Standard cd° refers to strobes that Include 15,15/75, 30, 75, 95,110, and 115 candela settings.°High cd° refers to strobes that include 135, 150, 177, and 185 candela settings. SYSTEM `..$ SENSOR° 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2009 System Sensor. Product specncatlan subiect to change *Mout notice VStt systemsenwcmn for mmttproduct Inktmatlon, tndudingdoelatestversion of Mrs data sheet A05-0395-007. 4/09.112132 WINDY CITY WIRE CABLE & TECHNOLOGY PRODUCTS, LLC 386 Internationale Drive Suite H, Bolingbrook, Illinois 60440 Tel: (708) 493-1191 Toll Free: (800) 379-1191 Fax: (630) 296-8100 Fire/Life Safety SmartWireTM UL Listed and Rated Type FPLR Multi -Conductor Multi -Conductor Non -Shielded Non -Plenum Fire Alarm P/N 728100 -16 AWG 2 Conductor Non -Shielded Non -Plenum Fire Alarm Description: Conductor Description: Insulation: PVC .010" Color Code: Black/Red Jacket: PVC .015" 16 AWG 2 Conductor Bare Copper, Non -Shielded Non -Plenum Fire Alarm UL Type FPLR 16 (Solid Bare Copper) Marking: FIRE/LIFE SAFETY CONTROL CABLE INIT. / IND. DEVICE/ ZONEA B CD E 0123456789 16 AWG "ROHS" -- TYPE FPLR 75C (UL) -- MADE IN USA Overall Diameter: .172" Nom. Capadtance: N/A Temperature and 75 C / 300 Volt Voltage Rating: Cable Weight: 29 Lbs/Mft. Agencies Approvals: NEC Article 760 UL FPLR, Califomia State Fire Marshal Approved, RoHS Compliant 4 6 r WINDYWIRE CABLE & TECHNOLOGY PRODUCTS, LLC 386 Internationale Drive Suite H, Bolingbrook, Illinois 60440 Tel: (708) 493-1191 Toll Free: (800) 379-1191 Fax: (630) 296-8100 Fire/Life Safety SmartWireTM UL Listed and Rated Type FPLR Multi -Conductor Multi -Conductor Non -Shielded Non -Plenum Fire Alarm P/N 727100 -18 AWG 2 Conductor Non -Shielded Non -Plenum Fire Alarm Description: Conductor Description: Insulation: Color Code: Jacket: Marking: Overall Diameter: Capadtance: Temperature and Voltage Rating: Cable Weight: 18 AWG 2 Conductor Bare Copper, Non -Shielded Non -Plenum Fire Alarm UL Type FPLR 18 (Solid Bare Copper) PVC .010" Black/Red PVC .015" FIRE/LIFE SAFETY CONTROL CABLE INIT. / IND. DEVICE / ZONE ABCDE0123456789 18 AWG "ROHS" -- TYPE FPLR 75C (UL) -- MADE IN USA .150" Nom. N/A 75 C / 300 Volt 22 Lbs/Mft. Agencies Approvals: NEC Article 760 UL FPLR, Califomia State Fire Marshal Approved, RoHS Compliant ' I* GE Security Overview Rechargeable sealed lead -acid batteries are ideal for use as a secondary (standby) power source as defined by NFPA 72. Their low maintenance and high energy density make them ideal for fire alarm signaling applications. Standard Features • Rechargeable • Non -spillable • Non -hazardous • Low maintenance • High energy density Sealed Lead -Acid Batteries Fire . Lfte Safety; Accessories Application When multiple power supplies are provided, each power supply's battery requirements should be calculated individually. Consult the specific system manual to determine battery capacity require- ments. Safety information Due to a bottery's low internal resistance and high power density, high level of short circuit current can develop across battery terminals. Put' on.pratective eye covering and remove all Jewelry before working on batteries. Do not rest toolsor cables on the battery, and only use insulated tools. Follow all manufacturers installation instructions and diagrams when instalfing or maintaining batteries. Data Sheet M85010-0127 Issue 3 Not to be used for installation purposes. Page 1 of 2 GE Security U.S. T 888-244-9979 F 866-503-3996 Canada T 519 376 2430 F 519 376 7258 Asia T 852 2907 8108 F 852 2142 5063 Europe T 32 2 725 11 20 F32 2 721 86 13 Latin America T 305 593 4301 F 305 593 4300 www.gesecurity.com/vigilant © 2006 General Electric Company All Rights Reserved Specifications Case Material ABS Thermoplastic Regulatory Information DOT Class 60, Batteries, non -hazardous, non -spillable Operating Environment 32° F to 120° F (0° C to 49° C) 0 to 93% RH, Non -condensing Ordering Information Cdtaiog Number Description 12V1A2 1.2 Ah Sealed Lead Acid Battery -12 Vdc Shipping Weight, (kg) 1.25 (0.57) 12V4A 4.5 Ah Sealed Lead Acid Battery -12 Vdc 5 (2.27) 12V6A5 7.2 Ah Sealed Lead Acid Battery -12 Vdc 6 (2.72) 6V8A 8 Ah Sealed Lead Acid Battery - 6 Vdc 4 (1.81) 6V10A 12 Ah Sealed Lead Acid Battery - 6 Vdc 5 (2.27) 12V10A 11 Ah Sealed Lead Acid Battery -12 Vdc 10 (4.45) 12V17A 18 Ah Sealed Lead Acid Battery -12 Vdc 13 (5.90) 12V24A 26 Ah Sealed Lead Acid Battery -12 Vdc 20 (9.07) 12V40A 40 Ah Sealed Lead Acid Battery -12 Vdc 32 (14.51) 12V50A 50 Ah Sealed Lead Acid Battery -12 Vdc 40 (18.14) 12V65A 65 Ah Sealed Lead Acid Battery -12 Vdc 49 (22.23) imagination'at work Data Sheet M85010-0127 Issue 3 Not to be used for installation purposes. Page 2 of 2