Loading...
HomeMy WebLinkAboutBLDG PERMIT #7714CITY OF CAPE CANAVERAL Tracking# BUILDING PERMIT APPLICATION 7714 - RECEIVED (321) 868-1222 City of Cape Canaveral Building Department 7510 N. Atlantic Ave. Cape Canaveral, FL 32920 You may download this application: -,,�,-\�,-,v.citvofcapecanaveral.orR. You may fax to: (321) 868-1247. Ail applications must include the backside of this form- Important: Please complete the checklist on the back of this form and provide other documentation as indicated on the checkhst A copy of contract may be required. Appbcation packages will not be accepted unless complete. APPLICANT WELL BE CALLED WHEN PERMIT IS READY. (Contractor/Owner-Bui Wer is required to sign for the building permit, unless indicated otherwise by affidavit. I.D. may be required) Address of Job Site: _-"� col LI -M k; hC- [Y11- R_ Zonm'2 classification: Flood Zone: Le -al description of prop TIAN: G:,D'-1 SEC: e Property Owner Name:L Address: ro L_ 72�- Fee Simple Titleholder's Npe (ifother timn owner): Bonding Company: - �Q 1�1_ Address: Mortgage Lender: 6 j,';7\ Address: Type of Permit I Brief description of work: Buildino, Electrical Plumbing Mechanical Other f yy) SUBD: BU<-- LOT: PB: PG: 0 � Phone: Address: VV%n-C-1 I I UPhiA1DYL'1LP1- . U U ki I Architect/Engineer Name: Address: Type of Name of Company: Const. 6cc- ' FPL lines City Sewer Will this Primary Contractor Name: Address:4��o Q1.6 ��D) Vu'A hl�- —F� F— Name of Company_-'_-P�3_C__0_ Lw� _a,� �;_ 2— f I VLe 1 U State License No.: Building Square Feet Type upancy Group currently available structure 9 of stories 4 of dwel- # of 9 of bed- water Valuation of work Name of Company: State License No.: (I'A, Phone (cell/pager.): available to to serve have built-in State License No.: Phone (office): (Copy of Contract Required) Fax: (picase under VB, (B,Rl, serve this this gas Fax: ting rooms closets indicate as roof etc) etc.) property? property? appliances? units applicable) Yes/No Yes/No Yes/No Fornmercial S ISFR S Townhouse $ Apartment S Condominiuni S Other I S'7Qnw I I Architect/Engineer Name: Address: Name of Company: State License No.: Phone (office): Phone (cell/pager): Fax: Primary Contractor Name: Address:4��o Q1.6 ��D) Vu'A hl�- —F� F— Name of Company_-'_-P�3_C__0_ Lw� _a,� �;_ 2— f I VLe 1 U State License No.: Phone (office�S Fax324,--?G. I gj I 01f hone (ceU/pager.)::S2) L Electrical Contractor Name: Aj 1p, Address: I Name of Company: State License No.: Phone (office): —Phone (ceftager.): Fax: Plumbing Contractor Name: Address: Name of Company: State License No.: Phone (office): Phone (cell/pager.): Fax: Mechanical Contractor Name: Address: Name of Company: State License No.: Phone (office): Phone (cell/pager): Fax: Specialty/Other Contractor Name: Address: Name of Company: State License No.: Phone (office): Phone (ceftager.): Fax: G: nz�.Sk;:� 11K. -nil, Appli�aliul! J11ty 12, �fj 1i) f Building Permit Application Checklist Notes Completed Permit Application Current code edition: FL Bldg. Code 2007 (as revised) Current survey showing all proposed construction and landscaping Check with Bid-.. Dept for setbacks Notarized signature — Ovmer[Builder Affidavit If owner is acting as contractor Sewer Impact Fee receipt May e deferred until C.O. Unless job is remodeling County Impact Fee receipt May be deferred until C.O. Capital Expansion Impact Fee receipt Maybe deferred until C.O. Sidewalk Impact Fee receipt If sidewalk exists on lot Recorded Warranty Deed / Proof of Ownersbip Copy of Recorded Notice of Commencement (over $2.500) Over S7-500 for Mechanical chan2e out Current Cert. Of Liability Ins.AVorker's Comp. Policy / E emption Record will be kept on file after initial subminal Community Appearance Board Approval For all work visible from Public Ri.-ht-Of-Way Plannine and Zonine Board Site Plan Approval For all new construction of four units or more Concurrency Forms For all new construction not part of approved site plan Primary Contractor's State License Record will be kept on file after initial submittal Subcontractor's Autliorizations: State License I Record will be kept on file after initial.submittal Notify Building Department of contractor changes Plumbing Contractor PlurnbinR Contractor Electrical Contractor Electrical Contractor =Mechanical Contractor Mechanical Contractor Roofing Contractor Roofing Contractor Swinuning Pool Contractor Swi ming Pool Contractor Gas Contractor Gas Contractor Specialty/Other Contractor Specialty/Other Contractor Construction Dra�Arings: FF er F.B.C. 104 Three sets of sealed construction drawings Per F.B.C. 104 Truss layout and reaction summary Cut sheets and shop drawings will be needed at time of insp. Electrical Load Calculations Plans must indicate person responsible for calculations Electrical Riser All new service must be located underground Plumbing Riser Plans must indicate person responsible for design A/C layout Plans must indicate person responsible for design Two sets ofEnergy Calculations Plans must indicate person responsible for calculations Lot Drainage Suivey Four sets ofFire Suppression/Sprinkler/Alarm specifications Requires Fire Dept. approval prior to issuance of permit Pool Barrier Requirement Form (signed) Pool per -n -tits witi not be issued without barrier Application is hereby made to.obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. The -Building Code in effect at the time of this application is the Florida Building Code 2007 Edition. I understand that all permits require inspections as indicated. This permit application is valid for six months from date of submission. By signing, applicant affirms that all above is true and correct and that he/she is an authorized agent of the Contractor/Owner and has the authority to apply for this permit. I I I Applicant's Name SyN&y,^!5(— . Applicantfs Sianaturz, Date: / / ho //0 Site Address: Y,30 am F�-- For Notary use only: State of Floridai County of E�nvard Sworn and subscribed before me t' day of 20 JZ) by_ J&-SoA Q), A�� Printed name oNApplicant who produced identification: or is personally known to me. NOTARY PUBLIC -STATE OF FLORIDA Beverly Paxton Sea]: t Commission # DD663224 ... WExpires: JUNE 01,2011 Signftqe - Notary Public At Large BONDED THRU ATLANTIC BQ.q11 )G Co., Dzc. G This form may be duplicated. Eli Pe zii1Ar,1.-,iic,21;, t BUILDING PERMIT FEES: Address: It—, Ove Building Permit per square footage: ............................................................. 7714 Total Sq. Ft. (Living Area): Total Sq. Ft. (Enclosed Area): Building Permit based on valuation: ............ ..... Q..S? ...................... Total Sq. Ft. (Living Area): z� cc. -I Total Sq. Ft. (Enclosed Area): . Building Permit miscellaneous: ...................................................................... Total Sq. Ft. (Living Area): rotal Sq. Ft. (Enclosed Area) Electrical.................................................... ........................................... 0 ............... Plumbing................................................................................................................. Wechanical ............... ........................................................................................... 3uilding Permit Plan Check Fee ..................................................................... .�ire Dept. Plan Check Fee .................................................... ............................. 7 footage.................................. -oncurrency Management Fee .......................................................................... -apital Expansion Fee ......................................................................................... Total Building Permit Fees: ...... ')EWER PERMIT FEES: SewerImpact Fee ...................................................................................... SewerTap Fee ............................................................................................ Total Sewer Permit Fees ............. By: Date: CANAVERAL FIRE RESCUE Serving the city of Cape Canaveral & Canaveral Port Authority Plan Review To: Building Department Joy Lombardi 7714 From: John J. Cunningham, Fire MarshaQiv- (1.1- Re: Colonial House 230 Columbia Dr. Fire Alarm Replacement Date: 12-16-2010 We have reviewed the plans and have the following comments; 1. This project will be done in phases. Phase 1 has been approved with additional phases starting with in 1 year of this permit. A permit will be required with each additional phase. Fire Alarm Devices: $165.00 Engineer fee: $100.00 Plan Review Fee: $ 265.00 Station #1: 190 Jackson Avenue Cape Canaveral, Florida 32920 (321) 783-4777 Fax: (321) 783-5398 Station #2: 8970 Columbia Road Cape Canaveral, Florida 32920 (321) 783-4424 Fax: (321) 783-4887 www.ccvfd.org City of Cape Canaveral Inter -Office Transmittal To: Johnny Cunningham From: Joy Lombardi, Building Department Re: 230 Columbia Dr. — Fire Alarm — Colonial House We Transmit: M Herewith THE FOLLOWING: 0 Plans El Prints El Other These are transmitted for: El Permit Issue El Approval Review & Comment El In accordance with your request 0 Specifications El Copy of Letter El Record 11 use I Copies Date Description 14 11/19/10 Fire Alarm Plans Remarks: Copies to: File El Shop Drawings 0 Information El Information El Distribution By: —ILombardi Space Coast Fire and Safety, Inc. TourSafety Is Our Business 420 Manor Drive Merritt Island Fl. 32952 www.spacecoastsafety.com John The Colonial House 230 Columbia Ave Cape Canaveral Fl. 32920 Phone: 321-806-8599 Fax: 321-452-2376 SUBJECT: Fire Alarm System Upgrade REFERENCE: The Colonial House Condo January 18. 2010 revised August 3 0, 2010 This quote is valid for 30 days I -vct &A.'— I �-Ss i +5C)r--h5 I /(�.IC5—qzoo Space Coast Fire & Safety Inc.'s Alarm Services Division Will provide and install the Fire Alarm System as detailed below; SECTION 1.0 SYSTEM DESCRIPTION / SCOPE OF WORK SYSTEM DESCRIPTION. We propose to expand the existing Addressable Fire Alarm (Bosch D7024). To bring the condo up to current fire code. Includes specified Devices, cabling, conduit, boxes and fire stopping of any penetration made by SCFS and a 11 OVAC. . CAD. drawings shall be created based on existing blueprints provided by customer. SCOPE OF WORK. This proposal includes all material as detailed below, electrical installation, device installation, programming, check out and training to provide a complete operating Fire Alarm System. Appropriate documentation will be provided to the customer and training on the operation of the system will be provided as required. Install /reuse conduit mi hallway for smoke detection in all common and storage areas. Penetrate each unit above kitchen to install mini sounders per NFPA 72. Replace all existing wire and devices, reuse existing raceway where possible. Add pull stations at the front lobby door and the center lst floor stairwell exit. Relocate pull stations on the Ist floor east and west end of hallway 25'to exit door. Add hom/strobe in the 1st floor office Toll Free: (866) Off -Fire Ph: (321) 783-1040 Fax: (321) 783-1516 Space Coast Fire and Safety, Inc. TourSafety Is Our Business 420 Manor Drive Merritt Island Fl. 32952 www.spacecoastsafety.com ELECTRICAL: Provide and install boxes for alarm devices in units. Supply power to new FAPI3 from e)dsting house panel. Run surface conduit. Utilizing existing raceway for new wire and devices Penetrate existing floor penetrations. Any holes cut shall have a blank plate to cover them. If they are larger then 2" X 4" do to any unforeseen issues, patching shall be done by others SECTION 3.0 BILL OF MATERLAL & SYSTEM PRICING Fire Alarm Control Panel NAC Power Supply 1 Fire Alarm Annunciator 1 Wall Mount Hom Strobes (Red) 18 Fire Alarm Smoke Detector 47 Ceiling Mount Hom Strobes (Red) Fire Alarm Heat Detector Wall Mount Strobe (Red) Fire Alarm Pull Station 12 Ceiling Mount Strobes (Red) Single Input Module Apartment Mini Horns (White) 56 Dual Input Module WP Wall Mount Strobe (Red) Single Output Module VY'P Strobe Back Box (Red) Magnetic Door Holder Voice Evacuation Panel Beam Smoke Detector Total Wattage 25,50, 100, 200 Conventional Duct Smoke Detector Remote Microphone Addressable Duct Smoke Detector Speaker Circuit Zone Sphtter Water Flow Connection Wall Mount Speaker Strobes (White) Tamper Switch Connection Ceiling Mount Speaker Strobes (White) Toll Free: (866) Off -Fire Ph: (321) 783-1040 Far: (321) 783-1516 Space Coast Fire and Safety, Inc. TourSafety is Our Business 420 Manor Drive Merritt Island Fl. 32952 www.spacecoastsafety.com PRICING Phase 1. Replace obsolete FACP and tie all existing zones/NACs to the D7024. $7,500.00 Design 2 weeks from award Permitting depends on AHJ Installation Begins 1 - 10 days after permit is issued Installation Complete 1 week Programming, Check Out and Training Day of final inspection Complete Bring complete building up to current fire code. Mini horns 'in all units, smokes in corridors and pull stations at every exit. Includes replacement of all existing wire with new $30,500.00 Installation Complete Programming, Check Out and Training Complete Estimated time in units Lease programs are available. PAYMENT TERMS 20% to start design and permitting Bi -weekly progress payments Net 15. 5 weeks Day of final inspection 2 hours each for electrical work I hour each for wire/device installation SECTION 4.0 EXCEPTIONS and CLARIFICATIONS I This proposal is void if not accepted in writing within thirty (30) days of this date. 2. All work will be performed during normal working hours and days (M -F 8:00am - 5:00pm). No provision has been made for overtime, weekend or holiday work. 3. Permit fees are not included 4. Sales taxes and freight are included. 5. Waste and disposal not included 6. Re -use existing raceway for existing exterior devices 7. Patching of drywall and/or concrete not included in base bid 8. Drywall rough patch 49.00 each(doesn't include texture, popcorn or paint) 9. Final Inspection with Fire Marshal 10. Replace all vAring with new FPLR/THHN wire Toll Free: (866) Off -Fire Ph: (321) 783-1040 Fax: (321) 783-1516 Space Coast Fire and Safety, Inc. TourSafety Is Our Business 420 Manor Drive Merritt Island Fl. 32952 www.spacecoastsafety.com 11. Fire Panel room may need to be air conditioned if humidity is 85% or higher. 12. Space Coast Fire would prefer an owner/owners representative be present while working in each condominium unit. 13. Does not include any additional requirements by the AHJ SECTION 5.0 WARRANTIES We guarantee our work to be free of defects for one year, during which repairs of defective workmanship and/or materials will be made at no cost. This warranty excludes Act of God, re -used products, re -used penetrations, items furnished by others, unauthorized service or negligent care. SCFS will extend the warranty on the installation for an additional year if we are the sole service and monitoring contractor. SECTION 6.0 MONITORING We will set up Fire Alarm Monitoring for the building. Monitoring quote is for twelve month (12) of service at $32.00 per month per building. This quote includes inter office/site programming and set-up. This will be billed quarterly, in advance. This price will be guaranteed for 2 years of service. Monitoring can be terminated after the first year with a (30) thirty day written notice. Sincerely, Space Coast Fire & Safety Inc. Jason Spina Manager ACCEPTANCE OF PROPOSAL The above prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payments will be made as noted above. )4- a_ -j Toll Free: (866) Off -Fire Ph: (321) 783-1040 Fax: (321) 783-1516 CH -L Invente'. 40� hf6, . D7024 -EXP Fire Alarm Control Panels The D7024 -EXP Fire Alarm Control Panels (FACPs) can be used in commercial and public building applications such as schools, universities, manufacturing plants, and health care facilities. The D7024 -EXP FACPs support four on -board initiating zones that can be expanded to eight using the D7034. Each initiating loop supports two -wire and four -wire detectors configurable as Class A, Style D (with D7014) or Class B, Style B loops. Each zone can support up to 20 two -wire detectors, or any number of four -wire detectors depending on available power. Each FACP has a built-in digital fire alarm communicator transmitter (DACT). Enhance the D7024 -EXP conventional system features when running version 2.02 or higher firmware by adding a D7039 Multiplex Expansion Module. Adding a D7039 Multiplex Expansion Module to the D7024 -EXP turns the conventional FACP into an addressable FACP. The D7039 adds up to 247 addressable points to the base system and adds an additional 400 events to the history buffer for a total of 499 events. The D7039 also increases the number of programmable relay outputs from 18 to 58 and allows up to 100 system users (an addition of 84 PINs to the base system). Four detector zones (expandable to eight); up to 20 two -wire smoke detectors per zone � Built-in DACT Two notification appliance circuits (NACs) on board with an internal 24 VFWR, 4 A NAC power supply Easily converts to addressable with the addition of a D7039 Multiplex Expansion Module Programmable through front panel interface, remote D7033 Liquid -crystal Display (LCD) Keypads, or remote programming software (RPS) i - F u n- c ii on s Notification Appliance Circuits (NACs) Two on -board Class B, Style Y or Class A, Style Z (with D7015) NACs provide up to 4 A of 24 VFWR power to operate horns, strobes, bells, and other notification appliances. Each NAC can be programmed to provide Temporal Code 3, steady, pulsed, and synchronized output for Wheelock' and Gentex" notification appliances. User Interface A viewing port in the keyed control panel enclosure door shows the systern status light�emitting diodes (LEDs) and LCD display while maintaining system keypad security. Unlocking the enclosure door provides access to the system controls for silencing off -normal conditions, zone bypassing, detector resetting, testing, other fire functions, and programming. These functions are also available on all D7033 LCD Keypads connected to the system. All D7036 LCD Annunciators provide custom text annunciation on a 32 -character, backlit, two-line LCD display. All system keypads and annunciators have built-in sounders. Back -light intensity and sounder volume are programmable. www.boschsecurity.com re' t:�R Fi' I�in lt� Personal Identification Numbers (PINs) Category There are 16 PINs available for accessing system control. Assign each number an authority level to limit access to the system control functions. Note The number of PINs increases to 100 with the addition of a D7039 Multiplex Expansion Module. History Buffer The system stores events in a 99 -event history buffer. Note The number of events that can be stored in the history buffer increases to 499 with the addition of a D7039 Multiplex Expansion Module. Central Station Reporting The D7024 -EXP FACPs send reports to two telephone numbers with full single, double, and backup reporting. They communicate in BFSK, SIA, Contact ID, Modem IIIa2, and 4/2 and 3/1 Tone Bursts. Dirty Smoke Detector Monitoring All on -board zones and D7034 zones are continuously monitored for smoke detectors signaling a dirty condition using the Bosch Chamber CheckO feature and CleanMeO protocol. If a detector's smoke chamber is dirty, the detector sends a CleanMe signal on the two -wire loop or a dirty detector signal on the addressable loop. The control panel annunciates that there is a dirty detector on the loop or the address. The Chamber Check feature signals a dirty smoke chamber using the LED on the detector head. Accessories The D7024 -EXP enclosure has space for additional accessory modules and two D1218 (18 Ah) batteries or two D126 (7 Ah) batteries. Installation/Configuration Notes Compatible Products The following products are compatible with the D7024 -EXP FACPs: Category ProductlD Product Description Batteries and D126 12 V, 7 Ah battery Power Supplies D1218 12 V, 18 Ah battery Smoke detector reversing relay mod- D7038 Remote NAC power supply Detectors For two -wire detectors, refer to D7022 -D7024 Com- D185 patibility List Technogram (P/N: 34445) Keypads and D703OX Eight -point LED annunciator Annunciators D7015 (eight red) D7031 D703OX-S2 Eight -point LED annunciator (two yellow, six red) D703OX-S8 Eight -point LED annunciator (eight yellow) Modules NAC Devices ProductlD Product Description D7032 Eight -zone LED annunciator expander D7035 (eight red) D7033 LCD fire system keypad D7036 LCD annunciator D132B Smoke detector reversing relay mod- Refer to D7024 NAC Compatibility List Technogram (P/ ule D184A Auxiliary local energy interface kit D185 Reversing polarity module D275 EOL power supervision module D7014 Zone converter module D7015 Class 8 to Class A NAC converter D7031 Silence reset module D7034 Four-pointexpander D7035 Octal relay module D7035B Octal relay module in box D7039 Multiplex expansion module D7039R Multiplex expansion module retrofit kit Refer to D7024 NAC Compatibility List Technogram (P/ N: 34950) D7048 The following additional product is compatible with the D7024 -EXP Addressable FACPs: Category ProductlD Product Description Modules D7042 Multiplex eight -input remote module D7042B Multiplex eight -input remote module in box D7044 Multiplex single -input module D7044M Mini multiplex single -input module D7048 Multiplex octal driver D70488 Multiplex octal driver in box D7052 Multiplex dual -input module D7053 Multiplex input-output module Pull Stations FMM-7045 Single-action manual station FMM-7045-D Double -action manual station Parts ImIucled. Quant Component 1 D7024 -EXP board in a static -resistant bag 1 Enclosure (P/N: 30897) 1 Lock set with 2 keys (P/N: 24065) I Transformer (P/N: 38602) 6 2.21 kO end -of -line (EOL) resistors (P/N: 25899 or 4998113202) 1 Hardware pack I Literature pack Note For the D7024 -EXP to be addressable, a D7039 Multiplex Expansion Module must be installed. The D7039 is purchased separately. Technical Speciricitions L Environmental Considerations Temperature (operating): OoC to +49'C Mechanical Properties Color: Red Dimensions (H x W x D): 52.8 cm x 38.1 cm x 10.9 cm Material: Cold -rolled steel Base: 1.2 mm Cover: 1.1 mm Outputs NAC: 24 VFWR nominal, 4 A maximum On -board Relays: Two Form C contacts rated at 5 A, 28 VDC Off -board Relays: Up to two D7035 Octal Relay Modules each provid- ing eight Form C relay outputs; contacts rated at 5 A, 28 VDC In an addressable system, upto 20 D7053 Multiplex Input -Output Modules per bus for a total of 40 Power Requirements Current (alarm): 380 mA Current (standby): 200 mA Power (primary) Sensor Circuits Current: 220 VAC, 1.5 A maximum, 50 Hz 44 mA maximum per loop Line resistance: 1500 Voltage: 24 VDC nominal D702, EXR re -A Arfti"� Trademarks Chamber CheckO is a registered trademark of Bosch Security Systems, Inc. in the United States. CleanMeo is a registered trademark of GE Interlogix in the United States and/ or other countries. Wheelock' is a trademark of Wheelock, Inc. Gentex" is a trademark of Gentex Corporation. Ordering Information D7024 -EXP FACP for Export D7024 -EXP Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone D7024-EXPLT FACP for Export without D7024-EXPLT Enclosure and Transformer Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone Accessories KEY -625 Replacement Key KEY -625 Replacement key www.boschsecurity.com Auxtericas-- Securi_ Bosch �y Systems. Inc. 130 Perinton ParKway Fairport, N— York, 14450. USA P hone: - 1 800 289 D096 585 223 9180 c curity.sales@us.bosch.com —.b�s.hsecurity.Ls F -rpp�. Middle East, Afro— Bosch Security Systems P.V. P.O. Box BOD02 5600 JS Eindhoven, The Netherlands Phone: - 31 40 2577 2B4 Fax: -31 40 2577 330 =sec raysystemspbosch.corn boschsecurity.com 0 B—h Security Systems 1— 20!0 1 Data subject to change v,Ith.ut notice T3642949899 I Cur: er-US. V6, 4 Jul 2010 A.ia-p..ific: Represented by Robert Bosch (SEA) Pte Ltd. Security Systems 11 Gishan Street 21 Sing.p.re 573943 Phone +65 6258 5511 Fax: -65 6571 2698 apr.securi-,ysystemsobosch.com W—boschsecurity.com SILENT Model 5495 Distributed Power Module 13's KNIGHT In an emergency, by Honeywell you need maximum power The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor@,GenteO, AMSECO@, Wheelock and Faraday — what you need to drive power- hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1-800-328-0103. Model 5495 Distributed Power Module The 5495 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls such as the Silent Knight Model 5208 Fire Control /Communicator. The 5495 is the cost- effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5495 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. Features UL Listed for 6 amps of notification power Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems Dip switches allow for easy reconfiguration 24 VDC filtered output voltage Four power -limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B Additional continuous auxiliary output 3 amps per output circuit 2 inputs; 2 Class B or 2 Class A Ground fault detector/indicator Independent trouble relay AC loss delay option shuts off power to non-essential high -current accessories like magnetic door holders Bu.ilt-in synchronization for appliances from System SensorO,GentexO, AMSECO@, Wheelock and Faraday . Stand alone operation Lightweight design adds to ease of installation and reduces shipping costs Operates with most polarized, UL Listed notification devices ANSI Cadence pattern output capability built-in Connection to Local Fire Control The 5495 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the inputs on the 5495. The control panel's notification circuit end -of -line resistor is also connected across two terminals on the 5495, which provides supervision between the 5495 and the fire control panel. Polarized audible and/or visual notification devices are then connected to the 5495 signal circuits using the 4.7kQ end -of -line resistors provided. Since the 5495 draws very little power from the control, it is possible to connect one 5495 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. Model 5495 Distributed Power Module Approvals UL Listed MEA429-92-EVoIXII CSFM 7300-0559:123 NFPA 72 Model 5495 Distributed Power Module Model 5495 Block Diagram Signal Circuit Output Signal Signal I Distributed Signal 2 Signal Circuit Output Signal 2 Power Input Module 5495 Signal 3 (Optional) Signal 4 120 VAC Aux.Power SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are FORM# 350395 Rev D subject to change without notice. For more information, contact Silent Knight @ 2010 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford, CT 06472-7161 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com Local Fire Control Trouble Output (Alternative to notification circuit trouble.) Supervision Current: Input The 5495 supervises a variety of Standby 75 mA voltage range: 9 - 32 VDC functions including: Alarm 205 mA Battery charging • Low AC power Auxiliary capacity: 35.0 AH • Low battery condition power circuit: 1 Ambient temp.: 32* to 120' F • Earth ground fault Notification (0' to 49' C) • Auxiliary output power limit circuits: 4 Mechanical condition Output Dimensions: 12.25" W x 16" H x • EOL supervision trouble or configuration: 2 Class A (Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output (1 Class A& 7.62 D cm) When a trouble condition occurs, 2 Class B) Indicator Lights the 5495 creates a trouble Amps per AC power on : Green condition on the h.ost control.s.ignal circuits to which it is-66nnected. the output circuit: 3.0 (6.0 amps total) Battery trouble: Yellow 5495 still maintains the.ability to be Notification Ground fault: Yellow activated by the host control. In circuit output: 20.4 to 27.3 VDC Aux trouble: Yellow addition, the 5495 provides a Form @ 3.0 amps each, C trouble relay output as an 4.7 kQ EOL Output troubles (1-4): Yellow alternative to using the notification resistor required Ordering Information circuit trouble. on each Class B 5495 Distributed Power Module circuit Electrical Specification No. of inputs 2 AC input: 120 VAC at 2 amps Input Output: 24 VDC at 6 amps configuration: 2 Class B or 2 Class A SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are FORM# 350395 Rev D subject to change without notice. For more information, contact Silent Knight @ 2010 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford, CT 06472-7161 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com The D7033 LCD Keypad combines remote annunciator and controller functions for fire alarm systems controlled by the D7024 Fire Alarm Control Panel (FACP). It operates identically to the user inter -face on the D7024 FACP. You can connect up to four D7033 keypads to a D7024. Also use it to program the D9068 Fire Digital Alarm Communicator Transmitter (DACT). The D7033 allows remotely starting local system tests, system programming, system control, and viewing the system's event log. Passcode protect access to system functions allowing installation in areas open to the general public. The two-line, 32 -character LCD (liquid -crystal display) annunciates system status and events. The top line provides general system status information, while the bottom line identifies specific devices or procedures. An internal sounder signals alarm and trouble conditions and annunciates keystrokes during programming and control procedures. Four status LEDs indicate power, alarm, trouble, and silenced conditions. A pull-out slide With operating instructions fits behind the mounting base. BOSCH 1 vent r e 0 .0d fo'. I i f Compatible with the D7024 FACP Two-line, 32 -character, alphanumeric LCD display Status LEDs identify alarm, trouble, power, and silenced conditions Address setting by jumper Remotely control system including commands and programming Passcode protection controls system access Low -profile design Certifications and Approvals Region Certification USA UL UOXX: Control Unit Accessories, System (UL864, 9th edition) FM CSFM 7165-1615: 147 July 2008 NYC -MEA 12-92-E,Vol.Vil 12-92-E,Vol.Vll 12-92-E, Vol. 14 12-92-E, Vol. 14 26-02-E, Vol. 11 26-02-E, Vol. 11 Installation/Con'figuration Notes Compatible Products The folio ' wing products are compatible with the D7033 LCD Keypad: Category Product ID Product Description Control Panels D7024 FACP D7024EXP FACP for export Keypadsand D703OX LED annunciator Annunciators D7030XS2 LED annunciator D7030XS8 LED annunciator Transmission D9068 Fire DACT Devices www.boschsecurity.com Mounting Mount the D7033 on a single -gang or four -inch square back box. Wiring Guidelines • Do not share keypad wiring with multiplex, telephone, or NAC wiring. • Use a minimum of 22 AVVG (0.8 mm) four -wire cable; but do not use twisted pair or shielded cable. Note A minimum of 18 AVVG (1.2 mm) cable is needed for NEC-NFPA-72. • Do not exceed 1000 ft (305 m) between the control panel and the remote keypads. • Do not exceed the total amount of keypad wiring permitted per system which is limited to a maximum of 4000 ft (1219 m). Number of keypads Do not connect more than four keypads. Place up to two keypads along any single 1000 ft (305 m) run of 22 AVVG (0.8 mm) wire. Three keypads can be used on any single 1000 ft (305 m) run of 18 AVVG (1.2 mm) wire. Technical.Specifications Environmental Considerations Relative Humidity: 5% to 85% at +86'F (+30oC), non -condensing Temperature (Operating): +32*F to + 122oF (OC to +50-C) Mechanical Properties Dimensions (H x W x D): 4.6 in. x 6.3 in. x 1.2 in. (12 cm x 16 cm x 3 cm) Power Requirements Current (alarm): 100 mA Current (standby): 80 rnA Voltage (operating): 12 VDC nominal 'OrderingInformation".."- - -- - ------ D7033 LCD Keypad D7033 Combines remote annunciator and controller functions for fire alarm systems controlled by the D7024 Fire Alarm Control Panel A—m— Bosch Security Systems. Inc. 130 Perintor, Parkway cairoort, New York, 14450, USA Phone: - 1 SDO 289 0096 Pa. -1 58� 223 9180 security.salespus-bosch.com —bosch-curity— Europe, Middle East, Africa: Bosch Security Systems B.V- P-0- Box 80002 5600 JS Eindhoven, The Netherlands Phone: + 31 40 2577 284 F- -31 40 2577 330 1mea.securitysystemsQbcsch.com —boschsecurity.com 0 Bosch Security Systems Inc. 2010 1 Data subject to change without notice T130,0362379 I Cur: e. -US. V8, 4 Jul 2010 Asia-Pacific: Represented by Robert Bosch (SEA) Pte Ltd. Security Systems 11 Bishan Str--% 21 Singapore 573943 Phone: +65 6256 5511 Fax: +65 6571 2698 apr.s�uCitysys-.ems@bosch.com —b-chs—,ity.c.. I . 6 -1 Fire-LiTerALarms A PITTWAY COMPANY GENERAL The Fire -Lite BG -10 Series Manual Fire Alarm Stations provide dual -action, normally -open contact alarm initiating points for use with UL listed fire alarm control panels. The BG -10 Series features non -coded, dual -action operation. FEATURES Within ADA 5 lb. pull force when used without break -tube (models manufactured after 10-1-96, identified by an (9 under station spring). Impact -resistant, durable LEXANO (or polycarbonate equivalent) housing. Back plate made of 16 gauge steel. Highly visible. Easily operated. Attractive shape with textured finish. Semi -flush or surface mounting. Operates with or without a break tube. Handle latches in down position to clearly indicate that the station has been operated. Optional lock with standard Fire -Lite key. Optional N.O. contact for auxiliary functions. Optional pre -signal circuit. Spanish (FUEGO) version available. APPLICATIONS The BG -10 Series manual fire alarm stations are intended for use as fire alarm initiating devices, with any fire alarm initiating circuit to be operated by a contact closure. The stations are for indoor or outdoor (BG -1 OWP) use and should be installed in compliance with applicable NFPA standards, local building codes, and plans and specifications. INSTALLATION The BG -1 0 Series manual fire alarm stations mount to stan- dard single -gang electrical boxes. A terminal block with screws allows for fast and easy wiring. OPERATION Pulling the handle down causes the BG -10 to latch in the down position and to close the normally -open switch. The handle is restored manually by unscrewing the allen-head screw so the top of the case can pivot forward, allowing the spring-loaded handle to return to its normal position. The case can then be pivoted back to its normal position and secured with the allen-head screw. The BG -10L utilizes a mechanical key instead of the allen- head screw. The BG -1 OP/T has a normally -open auxiliary switch which is closed by rotating a key clockwise. (The key is non -remov- able in this position.) July 29, 1999 F-1 00 BG- 10 Series Manual Fire Alarm Stations Section: Conventional Initiating Devices California State Fire Marshal S9 7150-0075:103 S711 CS115 AD_A < OG5A5.AY SPECIFICATIONS Physical: Electrical: Current Capacity: 3 Amps @ 30 VRMS. LEXANO is a registered trademark of GE Plastics, a subsidiary of General Electric Company. This document is not intended to be used for installation purposes. We try to keep our 22222r—. product information up-to-date and accurate. We cannot cover all specific applications or 'SO -9001 HKODY-1 anticipate all requirements. All specifications are subject to change without notice. For Engineering and Manufacturing more information, contact Fire -Lite. Phone: (203) 484-7161 FAX: (203) 484-7118 Quality System Certified to Fire-LIMALarms One Fire -Lite Place, Northford, Connecticut 06472 International Standard ISO -9001 Made in the U.S.A. (a I— DF -51203 — Page 1 of 2 BG -10 SB -10 WP_1 0 Height 5.500 inches 5.500 inches 6.000 inches (1139.700 mm) (139.700 mm) (152.400 mm)_ - Width 4.125 inches 4.125 inches 4.690 inches (1104.775 mm) (104.775 mm) (119.126 mm) Depth 1.375 inches 1.375 inches 2.000 inches (34.925 mm) , (34.925 mm) (50.800 mm) Electrical: Current Capacity: 3 Amps @ 30 VRMS. LEXANO is a registered trademark of GE Plastics, a subsidiary of General Electric Company. This document is not intended to be used for installation purposes. We try to keep our 22222r—. product information up-to-date and accurate. We cannot cover all specific applications or 'SO -9001 HKODY-1 anticipate all requirements. All specifications are subject to change without notice. For Engineering and Manufacturing more information, contact Fire -Lite. Phone: (203) 484-7161 FAX: (203) 484-7118 Quality System Certified to Fire-LIMALarms One Fire -Lite Place, Northford, Connecticut 06472 International Standard ISO -9001 Made in the U.S.A. (a I— DF -51203 — Page 1 of 2 I . 6 41 Wiring of Standard Unit: BG -1 0 TO CONTROL PANEL DETECTOR LOOP OUTPUT TO NEXT DEVICE OR E.L.R. Additional Switch Included With Models: BG -1 OA BG -1 OLA TO L_' TERMINAL BLOCK FOR N.O. CONTACT FOR AUXILIARY FUNCTIONS Additional Switch (Key -Operated) Included With Models: BG -10P BG -10T IN TERMINAL 131. FOR TEST, 0 PRESIGNAL Cl (KEY OPERATED) The BG-10SP PRODUCT LINE INFORMATION Model Description Standard unit. Dual action. Works with or BG -10 without a crush tube. Includes a terminal block with screws for fast and easy wiring. BG -10A Standard unit plus an auxiliary N.O. switch to provide annunciator contacts. BG -10T Standard unit plus key -test feature. BG -10P Standard unit plus N.O. switch for pre - signal operation. BG -10L Standard unit plus key locking feature. Standard unit plus an auxiliary N.O. switch BG-10LA to proAde annunciator contacts, plus key locking feature. Standard unit with a weather gasket BG-10WP (BG -10W). Includes appropriate surface backbox (WP -1 0) for outdoor applications. Spanish version of standard unit. BG-10SP Dual action. Works with or without a crush tube. Includes a terminal block. WP -10 Surface backbox for outdoor applications (used withfincluded with BG-10WP). SB -10 Surface -mount backbox for all BG -1 0 models. BG -TR Optional trim ring. ARCHITECTURAVENGINEERING SPECIFICATIONS 512030.tol Manual Fire Alarm Stations shall be non -coded, break -tube (or non -crush tube) type, with a key -operated test -reset lock (or Hex reset) in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key (or Hex). An operated station shall automatically condition itself so as to be visually detected, as operated, at a minimum distance of 100 feet (30.48 meters), front or side. Manual Stations shall be constructed of LEXAN@ (or polycarbonate equivalent) with clearly visible operating instructions on the front of the stations in raised letters, 1.75 inches (44.45 mm) or larger. Stations shall be suitable for surface mounting on matching backbox, or semi - flush mounting on a standard single -gang box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) dependent on manual station accessibility or per local requirements. Manual Stations shall be Underwriters Laboratories listed. Page 2 of 2 — DF -51203 GE Security overview GE brand 500 Series two- and four -wire conventional photoelectric smoke detectors bring together trusted technology and a full line of features that meet the demands of every type of application. The 500 offers sounders in 'two- and four -wire applications, Specifically to meet residential code requirements. The 500 Series also offers choices for optional auxiliary relays and isolated heat sensors, not available before in the 500 Series. GE is also proud to offer proven technology like CleonMe", dust compensation, field replaceable optical chambers, and self -diag- nostics. CleonMell is only available on the 500 2 -wire models and will communicate to the GE FireworX panels when servicing is required. SOO Series detectors work on a light -scattering principle. A pulsed infrared light -emitting diode serves as the light source, and a high- speed photo diode as the sensing element. This design has superior protection against nuisance alarms caused by dust, insects, RF interference, and ambient light. The proprietary optical chamber is field replaceable. In the event of a confirmed olo. rn the LED will light continuously. The unit indicates trouble by flashing the LED eve, y second. This meets the NFPA 72 1 leld sensitivity testing requirements. Units with built-in 85dBA sounders emit a temporal 3-3-3 tone pattern when in alarm and will emit a steady tone when the input power is reversed. All wiring terminates in clamp -type screw termi- nals. The detectors mount to a standard single -gang electrical box, a four -inch octagonal, four -inch square electrical box, or WIREMOLD No. 5739 fixture box. Smoke Detectors with Auxiliary 0 Functions 500 Series Fire & Life Scifet�, Y Smoke Detection Standard Features • Remote maintenance (CleanMeO) reporting (2 -wire models) and built-in drift compensation reduces false alarms • Self diagnostics eliminates the need for external meters • Field -replaceable optical chamber makes service fast and simple • Small, low profile design blends with any environment Optional auxiliary -functions include: • Integral sounder • Fixed/Ro te-of- Rise heats • Auxiliary relay • Single station smoke with system heat • Built-in power supervision relay IA VL R �9 EXAM C MEA Data Sheet FX85001-0606 Issue 1 Not to be used for installation purposes. Page I of 2 I . 4 Application 500 Series detectors are ideal for both retrofit applications and new installations alike. They are particularly well-suited for installations where detector reliability is essential, but where analog devices may not be appropriate or feasible. With their replaceable optical cham- bers, these detectors are equally well-suited to dusty environments where detectors require frequent cleaning. Mounting and Installation 50ON detector bases mount directly to standard single -gang electri- cal boxes, three-inch round, or four -inch octagonal boxes. Detector heads simply twist onto the base. Heads ore equipped with a break- away locking tab, Which prevents unauthorized removal. Terminals accept 12 to 24 AWC field wiring. Typical Wiring 2 -wire Initiating Circuit Listed Alarm Control Specifications Electrical Power Supply 8.5-33VDC (12/24 V operation) polarity sensitive Maximum ripple Dk-pk (6/12/24V) 10% (Vpk-pk) Typical average standby current 70 pA Typical alarm current (6/12/24V) up to 60 mA max if not limited by control panel Auxiliary relay contacts 1.0 A @ 30 VDC, Form C Alarm contacts 500 mA @ 36 VDC (resistive) Photoelectric sensitivity 3.1% + 0.5 - 1.0% Environment Operating temperature 32' -to 100' F 10' -to 37' 0 Operating humidity range 0 to 95% non -condensing RFI immunity 20 Wm min; 0-1000 MHz Assembly Optional fixed temperature sensor Diagnostic LED Optional rate -of -rise sensor Photoelectric sensor Replaceable optical chamber Detector cap Dimensions 2" (5cm) 5' (1 2cm) .""' C' EOL Device + Last First Detector Detector ff 0 �,� 0 Color White Field wiring size 12-24 AWG (16-22 recommended) Detector packaging 10 detectors per carton Heat detector specifications Rote -of- Rise: 15' F/min and >105� F 18.3' C/min and >40.6' Q Fixed Threshold: 135' F (57.2' Q UL 2 -wire compatibility identifiers S10A, S11A Drift compensa-. ion adjustment 1.0% -ft. max Detector head dimensions S.5 D x 2" H (14.0 x 5 cm) Mounting dimensions 5.25" 113.3 cm) diameter; 0.3" (0.8 cm) height Regulations Reset time 1 second min Listings C -UL -US, CSFM, MEA Data Sheet FX85001-0606 Issue 1 Not to be used for installation purposes. Page 2 of 2 Ordering Information Model Description Compatibility Alarm Current (mA) Reverse 541C 4 -wire, photoelectric, 6-33VDC N/A polarity (mA) S21B 2 -wire, photoelectric, 6-33VDC S09A/S10A 5 min. - 60 max. 5218XT 2 -wire, photoelectric, 6-33VDC, fixed temp and rote -of -rise heat S09A/S10A 5 min. - 60 max. 521NCRXT 2 -wire, photoelectric, 8.5-33VDC, fixed temp and rote -of -rise heat, oux. relay S11A 15 min. - 60 max. 521NCSXT 2-wire,.Dhotoelectric, 8-5-33VDC, fixed teMP and rote -of -rise heat, temporal 3 S10A 10 min. - 60 max 10 541NCRXT sounder N/A 25 52!NCSRXT 2 -wire, photoelectric, 8.5-33VDC, fixed temp and rate -of -rise heat, aux. relay iemporal 3 sounder S11A 15 min. - 60 max io 541C 4 -wire, photoelectric, 6-33VDC N/A 20 541CXT 4 -wire, photoelectric, 6-33VDC, fixed temp and rote-ol-rise heat N/A 20 541NCSRXT 4 -wire, photoelectric, 8.5-33VDC, fixed temp and rote -of -rise heat, aux. relay, temooral 3 sounder N/A 35 13 541NCSXT-L 4 -wire, photoelectric, 8.5-33VDC, fixed temp and rate -of -rise heat, built-in end all line relay, temporal 3 sounder N/A 45 28 S41NCSRH /,-wire, photoelectric. 8.5-33VDC, isolated fixed temp and rate -of -rise heat, oux. relay, iemporal 3 sounder, non-latChing LED with auto reset N/A 3S 13 541NCRXT 4 -wire. Photoelectric, 8.5-33VDC, fixed teM.D and rate -of -rise heat, oux. relay N/A 25 541NCXTE 4 -wire, ' Dhotoelectric, 8.5-33VDC, fixed temP and rote -of -rise heat, built-in end a,' line relay N/A 35 54INCSXT 4 -wire, ' Dhotoelectric, 8-5-33VDC, fixed temp and rote -of -rise heat, temporal 3 sounder N/A 30 13 548C 4 -wire. photoelectric, 8.5-33VDC, ULC Listed 548CT 4 -wire, photoelectric, heat, 8.5-33VDC, ULC Listed Note: Only 500 Series 2 -wire smoke detectors are CleonMe compatible. Options (ad d th e following suffixes as approp riate) B 6-33VDC operation C 8.5-33VDC operation E End-ol-Line relay H Isolated rote -of -rise and fixed temp senso, s .R Auxiliary relay 85dBo sounder -S XT Rate -of -rise and fixed temp sensors Accessories 405-05 Polarity reversal module enables sounder interconnection ofoll 4 -wire smoke detectors. when initiating detector sounds all smokes sound. 401 Test magnet in a plastic shell for pole mounting SM200-12PKG Smoke in a Con!O conned smoke -or functional testing SM -ex -,1L Smoke in a Con!O extension tube 211-IOPKG ReplocemenT optical chambers (set of 10) SOOPLT-5PKG 6" trim ring for wider coverage area Data Sheet FX85001-0606 Issue 1 Not to be used for installation purposes. Page 3 of2 G F Security U. S. T 888-GESECURITY F 503-691-7566 Canada T 519 376 24-30 F 5-19 376 7255 Asia T 852 2907 8108 F 852 2142 5063 Latin Americo T 305 593 4301 F 305 593 4-300 www.gese.--irity.com/',, eworx Q 2009 General Electric Company All Rights Reserved 0 imagination at work V Data Sheet FX85001-0606 Issue 1 Notto be used for installation purposes. Page 4 of2 . % A 0 Selectable -Output Horns, Strobes, and Horn Strobes SpectrAlert'Advance selectable -output horns, strobes, and horn strobes are rich with features guaranteed to cut installation times and maximize profits. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24 -volt operation at 15 and 15/75 candela Field -selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110,115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall and ceiling units Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with existing SpectrAlert products Compatible with MIDL sync module Agency Listings SIGNAUNG (D <�> USTED �RDVED r—bes. h-) 3023572 S55 2 L"'we') CN- mbm) SPECTRAlert The SpectrAllert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, horns, strobes, and horn strobes include a variety ol features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, which make installations last and foolproof while virtually eliminating costly and time-consuming ground faults. Furthermore, a universal mounting plate with an onboard shorting spring tests wiring continuity before the device is installed, protecting devices from damage. In addition, field -selectable candela settinas, automatic selection ol 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. MEA approved -i65 --:18E (nd­–,ob�) 77125 125-1653 ISE (-n s,robes. MEA�52-05-E CN- mbm) 7135-1653-16; 0-s. d­�) SPECTRAlert The SpectrAllert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, horns, strobes, and horn strobes include a variety ol features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, which make installations last and foolproof while virtually eliminating costly and time-consuming ground faults. Furthermore, a universal mounting plate with an onboard shorting spring tests wiring continuity before the device is installed, protecting devices from damage. In addition, field -selectable candela settinas, automatic selection ol 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2 -inch back box, 4 -inch octagon back box, or double -gang back box Two -wire products shall also mount to a single -gang 2 x 4 x 11/8 -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync -Circuit- Module accessory, shall be powered from a non -coded notification appliance circuit output and shall opeiate on a nominal 12 or 24 volts. When used with the Sync -Circuit Module, I 2 -volt -rated notification appliance circuit outputs shall operate between 9 and 17.5 volts, 24 -volt -rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a reoulated DC or full -wave rectified unfiltered powe. supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75,95,110,115,135,150,177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model - listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a prima ry-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at I Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlen Advance Model - listed to UL 1971 and UL 464 and shall be approved for fire protective service -The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at I Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three -pattern and a non-tempoial (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync -Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SPectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4'1/16 x 4"/16 x 21/s -inch back box. The module shall also control two Style Y (class B) circuits or one Style 7 (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Standard Operating Temperature 32'F to 120'F (O'C to 49'C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate I flash per second Nominal Voltage Regulated 12 DC/FW1R or regulated 24 DC/FWRI Operating Voltage Range' 8 to 175 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauqe 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8- diameter x 2.5 - high (173 mm diameter x 641 mm high) Wall -Mount Dimensions (including lens) 5.6-L x 4.7-W x 23-D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5-6-L x 4-7-W x 1.3-D (142 mm L x 119 mmWx 33 mm D) Wall -Mount Back Box Skirt Dimensions (BBS -2, BBSW-2) 5.9-L x 5.0-W x 2.2-D (151 mm L x 128 mmWx 56 mm D) Ceiling -Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2) 7.1 -diameter x 2.2 -high (180 mm diameter x 57 mmhioh) Wall -Mount Trim Ring Dimensions (sold as a 5 pack) JR -HS, TRW -HS) 5.7-L x4.8 -W x 0.35-D (145 mm L x 122 mmWx 9 mm D) Ceiling -Mount Trim Ring Dimensions (sold as a 5 pack) (TRC -HS, TRCW-HS) 6.9 -diameter x 0.35- hiah (175 mm diameter x 9 mm hiah) Notes: 1. Full Wave Rectified (FWR) voltaae is a non-regulated, time -varying power source that is used on some power supply and panel outputs - 2. F, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05 -03%-W UL Current Draw Data Temporal Low 129 151 76 84 86 101 160 184 98 194 Medium 201 Non -Temporal High 142 161 103 8-17.5 Volts 16-33 Volts 126 181 203 8-17.5 Volts 221 16-33 Volts 229 Candela DC FWR DC 4 Non -Temporal FWR 110 Sound Pattern clB DC FWR DC FWR Standard 15 123 128 66 90 71 161 Temporal Hiah 57 55 211 69 75 Candela Range 15/75 142 148 77 92 81 185 Temporal Medium 44 49 297 58 69 101 30 NA NA 94 265 96 235 Te mP or a I Low 38 44 Temporal Medium 44 48 224 75 NA NA 158 232 153 282 Non -temporal Hiah 57 56 207 69 75 248 95 NA NA 181 303 176 Non-tempofal Medium 42 50 60 69 Non-Iemporal Medium 110 NA N A 202 195 219 Non -temporal Low 41 44 Non -Temporal Low 50 50 291 115 NA NA 210 214 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 Elm&= NHM���- R B U, 91 1111] A LILF401MUNWAIRM9 8-17.5 Volts 16-33 Volts DC Input 15 15n5 15 15n5 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 so 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -Temporal High 141 152 91 100 116 176 201 221 229 Non -Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Tempoial Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 98 103 160 184 202 206 Temporal Low 129 151 76 84 86 101 160 184 98 194 Medium 201 Non -Temporal High 142 161 103 86 112 126 181 203 71 221 76 229 Non -Temporal Medium 134 155 85 4 Non -Temporal 95 110 166 189 88 208 92 216 Non -Temporal Low 132 154 80 78 90 105 161 184 98 202 6 Non -Temporal 211 DC Input 16-33 Volts 135 150 I I I -111;;-��,�', 177 185 98 FWR Input i*Egl , 16-33 Volts 135 150 92 177 185 Temporal High 245 259 290 297 92 Temporal High 101 215 231 78 258 265 Temporal Medium 235 253 288 297 91 Coded Temporal Medium 75 209 224 81 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 309 Non -Temporal High 233 248 275 281 Non-Iemporal Medium 242 259 293 299 Nori-Temooral Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Horn Tones and Sound Output Data 5 &q- 8-17.5 16-33 Switch Volts Volts Position SoundPattern clB DC FWR DC FWR MUM 24 -Volt Nominal Reverberant Anechoic DC FWR DC FWR I Temporal High 78 78 84 84 88 83 99 98 2 Temporal Medium 74 74 80 80 86 86 96 % 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non -Temporal High 82 82 88 88 93 92 100 100 5 Non -Temporal Medium 78 78 85 85 90 90 98 98 6 Non -Temporal Low 75 75 81 81 98 94 96 92 71 Coded High 82 82 88 88 93 92 101 101 8: Coded Medium 78 78 85 85 90 90 97 98 91 Coded LOW 75 75 81 81 98 85 96 92 7, 8, and 9 are noi available on 2 -wire horn strobe. AO��-1,6-007 SpectrAlert Advance Dimensions —4.7* —2.5 0. DiI 2.5- 5.6' Wall -mount horn strobes Ceiling -mount horn strobes —5.05'— 2.23:1 F ��� C__ C_ LU__1j; �_� Wall back box skirt SpectrAlert Advance Ordering Information Wall Horn Strobes _P2R` 2-Wrre Horn Strobe, Standard cd', Red P2RH* 2 -Wire Horn Strobe, High cd, Red P2W* 2 -Wire Horn Strobe, Standard cd, White P2WH* 2 -Wire Horn Strobe, Hiah cd, White P4R* 4 -Wire Horn Strobe, Standard cd, Red P41RH 4 -Wire Horn Strobe, High cd, Red P4W 4 -\Afire Horn Strobe, Standard cd, White Wall Strobes S'R*' Strobe, Standard cd, Red SRH*� Strobe, High cd, Red Sw* Strobe, Standard cd, White SWH' Strobe, High cd, White Ceiling Horn Strobes PC2R- 2 -Wire Horn Strobe, Standard cd, Red PC2RH 2 -Wire Horn Strobe, Hich cd, Red PC2W` 2-Wrre Horn Strobe, Standard cd, White PC2WH* 2 -Wire Horn Strobe, High cd, White PC4R 4 -Wire Horn Strobe, Standard cd, Red PC4RH 4 -Wire Horn Strobe, High cd, Red PC4W 4 -Wire Horn Strobe, Standard cd, White 7.1- 2.25--1 Dia. 0 CS C__ 0 Ceiling back box skirt Ceiling Strobes SCR Strobe, Standard cd, Red SCRH Strobe, Hioh cd, Red SCW* Strobe, Standard cd, White SCWH Strobe, Hiah cd, White Horns HR Horn, Red HW Horn, White Accessories BBS -2 Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt, Wall, White BBSC-2 Back Box Skirt, Ceiling, Red BBSCW-2 Back Box Skirt, Ceiling, White TR -HS T rim Ring, Wall, Red TRW -HS T rim Rino, Wall White TRC -HS Trim Rina, Ceilind, Red TRCW-HS Ttim Rino, Ceilin gi, White Notes: Add'-P'to model number for plain housing (no'FIRE'marking on cover), e.g., P2R-P Add �SP'to model number for'FUEGO'marking on cover, e.g., P2R-SR t�'Standard cd'refers to strobes that include 15,15/7S, 30, 7S, 9S, I 10, and 115 candela settings."High cd'refers to strobes that include 135, 150, 177, and 185 candela settincs- 02009 Sysim S—ou SYSTEM 3825 Ohio Avenue - St. Charles, IL 60174 Rcd— s­fi� �bi�_ t� dh­?e mth= _.5_E_NS0R* Phone: 800-SENSOR2 - Fax: 630-377-6495 AOS-019S-0�-7. 41C- - =2i �2 jl� WINDY CITY WIRE CABLE & TECHNOLOGY PRODUCTS, LLC 386 Internationale Drive Suite H, Bolingbrook, Illinois 60440 Tel: (708) 493-1191 Toll Free: (800) 379-1191 Fax: (630) 296-8100 Fire/Life Safety SmartWire TM UL Listed and Rated Type FPLR Multi -Conductor Multi -Conductor Non -Shielded Non -Plenum Fire Alarm P/N 728100 - 16 AWG 2 Conductor Non -Shielded Non -Plenum Fire Alarm Description: 16 AWG 2 Conductor Bare Copper, Non -Shielded Non -Plenum Fire Alarm UL Type FPLR Conductor 16 (Solid Bare Copper) Description: Insulation: PVC .0101, Color Code: Black/Red Jacket: PVC .015" Marking: FIRE/LIFE SAFETY CONTROL CABLE INIT. / IND. DEVICE / ZONE A B C D E 0 1 2 3 4 5 6 7 8 9 16 AWG "ROHS" -- TYPE FPLR 75C (UL) -- MADE IN USA Overall Diameter: .172" Nom. Capacitance: N/A Temperature and 75 C / 300 Volt Voltage Rating: Cable Weight: 29 Lbs/Mft. Agencies Approvals: NEC Article 760 LIL FPLR, California State Fire Marshal Approved, RoHS Compliant VA� WINDY CITY WIRE CABLE & TECHNOLOGY PRODUCTS, LL.0 386 Internationale Drive Suite H, Bolingbrook, Illinois 60440 Tel:(708)493-1191 Toll Free: (800)379-1191 Fax:(630)296-8100 Fire/Life Safety SmartWireTM LIL Listed and Rated Type FPLR Multi -Conductor Multi -Conductor Non -Shielded Non -Plenum Fire Alarm P/N 727100 - 18 AWG 2 Conductor Non -Shielded Non -Plenum Fire Alarm Description: 18 AWG 2 Conductor Bare Copper, Non -Shielded Non -Plenum Fire Alarm UL Type FPLR Conductor 18 (Solid Bare Copper) Description: Insulation: PVC .0101, Color Code: Black/Red Jacket: PVC .015" Marking: FIRE/LIFE SAFETY CONTROL CABLE INIT. / IND. DEVICE / ZONE A B C D E 0 1 2 3 4 5 6 7 8 9 18 AWG "ROHS" -- TYPE FPLR 75C (UL) -- MADE IN USA Overall Diameter: .150" Nom. Capacitance: N/A Temperature and 75 C / 300 Volt Voltage Rating: Cable Weight: 22 Lbs/Mft. Agencies Approvals: NEC Article 760 LIL FPLR, California State Fire Marshal Approved, RoHS Compliant 4 6 1 �A 11� GE Security Olva M. -I M Rechargeable sealed lead -acid batteries are ideal for use as a secondary (standby) power source as defined by NFPA 72. Their low maintenance and high energy density make them ideal lor fire alarm signaling applications. Standard Features • Recharaeable • Non -spillable • Non -hazardous • Low maintenance • High energy density Sealed Lead-Adid Batteries Fire & Life Safety Accessories Application When multiple power supplies are provided, each power supply's battery requirements should be calculated individually. Consult the specific system manual to determine battery capacity require- ments. Safety. Information Due to a bot tterys low imernal resistance and high power density. high levels of short circuit current can develop across bauery -Lerminols. Put on protective eye covering and remove alliewelry before working on batteries. Do not rest tools or cables on the bottery, and only. use insulated tools. Follow all manufccturers installation instructions and diagrams when.insiolling or mainicining batteries. Data Sheet M85010-0127 Issue 3 Not to be used for installation purposes. Page I of 2 G Security U. S. Specifications T 8,rS-21','-9979 T E52 2907 8108 Ordering Information F 866-503-3996 Case Material ABS Thermoplastic Canada Regulatory Inlormation DOT Class 60, Batteries, non -hazardous, non -spillable T 519 376 2430 Opera -Ling Environment 32' F to 120' F (0* C to 49'C) 0 to 93% RH. Non -condensing F 519 376 7258 T 32 2 725 1120 12V1A2 Asia T E52 2907 8108 Ordering Information F 852 2142 5063 Europe Catalog Number Description Shipoing Weight, lb.(kg) T 32 2 725 1120 12V1A2 1.2 Ah Sealed Lead Acid Battery - 12 Vdc 1.25(0.57) F 32 2 72186 13 12V4A 4.S Ah Sealed Lead Acid Battery - 12 Vdc 5(2.27) Latin Americo 12V6A5 7.2 Ah Sealed Lead Acid Battery - 12 Vdc 6(2.72) T 305 593 4,301 6V8A 8 Ah Sealed Lead Acid Bouery - 6 Vdc 4 (1.81) F 305 593 4300 6V10A 12 Ah Sealed Lead Acid Battery - 6 Vdc 5(2.27) wwwgesecuri,,y.com/vigilon, 12VIOA 11 Ah Sealed Lead Acid Battery - 12 Vdc 10(4.45) 12V17A 18 Ah Sealed Lead Acid Battery - 12 Vdc 13(5.90) Q 2006 General Electric Company 12V24A 26 An Sealed Lead Acid Battery - 12 Vdc 20(9.07) All Rights Reserved 12VI40A 40 Ah Sealed Lead Acid Battery - 12 Vdc 32(14.51) 12V50A 50 Ah Sealed Lead Acid Sou ery - 12 Vdc 40(18.14) 12V65A 65 Ah Sealed Lead Acid Battery - 12 Vdc 49(22.231 imagination at work Data Sheet M85010-0127 Issue 3 Not to be used for installation purposes. Page 2 of 2