HomeMy WebLinkAboutBLDG PERMIT #9243 (windload cert.) 0,2c0,.1- #. 9 Y/3
111 ALLIED DOOR AND HARDWARE COMPANY, INC.
PRESENTS
WINDLOAD CERTIFICATION DATA
FOR
Project Name:
Beachwave
AM 6605
Customer:
Doug Wilson Enterprises
Prepared by:
Cynthia Foster
klorldaMulcting Lode Online http://www.tloridabuilding.org/pr/prapp_dtl.aspx!param=wGEVXQ...
•ounr3scilAuTYetc;
Business.:& Professional:Regulation .
rmmer
��,i:;�J i �y�;Irr„^,•(t` BC6 Home Log In I User Reestraten I Hot Topcs Submit Surcharge Stats&Facts Pubtcalnns FBC Stag; BCLS See Mop inks Search
BUS'nes ()i
Profession( SUS adwwcUser val
.;egulaticn
U:ireeY:iltr;!f.P.ryagil4ley. Product Anomvel MEW>Prod rt nr raven Searrh>AnnirMen r qt>Ap If ion Detail
()FMBOFrr,C FL 3t FL11537-R4
s`vrerAaY .. Application'Type Revision
Code Version 2010
Application Status Approved
*Approved by DCA.Approvals by DCA shall be reviewed and ratified by the
POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer CURRIES Division of AADG,Inc
Address/Phone/Email 1502 12th Street NW
Mason City,IA 50401
(641)423-1334 Ext 4168
nelson.kraschel@doorgroup.com
Authorized Signature Nelson Kraschel
nelson.krasch el@doorgroup.com
Technical Representative Nelson Kraschel
Address/Phone/Email 1502 12th St NW
Mason City,IA 50401
nelson.kraschef@doorgroup.com
Quality Assurance Representative Nelson Kraschel
Address/Phone/Email 1502 12th St.NW
Mason City,IA 50401
(641)494-2846
nelson.kraschel@doorgroup.com
Category Exterior Doors
Subcategory Exterior Door Components
Compliance Method Certification Mark or Listing
Certification Agency Underwriters Laboratories Inc.
Validated By Underwriters Laboratories Inc.
Referenced Standard and Year(of Standard) Standard Year
ANSI A250.13 2003
ASTM E1886 2005
ASTM E330 2002
ASTME1996 2009
TAS 201 1994
TAS 202 1994
TAS 203 //�� 1994
Equivalence of Product Standards t,lZ.t*/
Certified ByApproved 1537 R4 Eauiv UL Letter of EAvivalencv.pSZf �
Fop
1oft
3/7/2013 9:33 AM
Florida Building Code Online htip://www.floridabuilding.orgfpr/pr_app_dthaspx?pararwGEVX0...
Product Approval Method Method 1 Option A
Date Submitted 02/20/2012
Date Validated 02/23/2012
Date Pending FBC Approval
Date Approved 02/27/2012
Summary of Products
IFL# Model,Number or Name DescriptionI.
-
11537.1 607,707,727,747,and 847 Single Flush,Glazed,and Louvered single and pairs of hollow metal
and Pairs of Doors doors.
!Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL11537 R4 C CAC Curries UL Door Certlficate.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 12/31/2017
Design Pressure:N/A Installation Instructions
Other:Mutipie Design Pressures Include 50,60,70, 115,100, FL11537 R4 II Curries Door Product Information and
and 150 psf.See RD0510r5 Curries Door Product Information Installation�ns�ruttlons.odf
and Installation Instructions for door gauge,options,and swing. Verified By: Underwriters Laboratories Inc.
Product is not qualified for Water Infiltration. Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party: •
11537.2 M,CM,and G Series Frames Three sided and four sided single and pairs of frames.Tansom—I
frames.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL11537 R4 C CAC Csbrries UL Frame CeAlficate,pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 12/31/2017
Design Pressure:N/A Installation Instructions
Other:Mutlpie Design Pressures Include 50,60,70,115,and 1L11537 R4 II Curries Frame Product Information and
t 150 psf.See RD0568r5 Curries Door Frame Product Information Installtio0Jnstru Ions oaf
I and Instalition Instuctions.Product is not qualified for Water Verified By: Underwriters Laboratories Inc.
!Infiltration.Weatherstrip frames may be used. Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
(ea� !Next'
fnMartttc::1g40_Hnrth Moue Street.Tallahassee FL32345 l t10Pe:RSn-497.1a24.
The State of Fbrda s an AA/EEO employer.fnfyutht2007.2010 atenrPlerra.:;privacy Statemont::6rsitsutgit bgemant::Wuxi Statement
Under Fbrda law,emai addresses are pubk records.If you do not want your a-mag address released in response to a pubic•records request,do not send electronic mai to the
entity.lrstead,contact the office by phone or by bac/Ronal mai.If you have any questons,please contact 850.407.1395.',Pursuant to Sector 455.275(1),Fbrda Statutes,
elfectve October 1,2012,kersees kensed under Chapter 455,F.S.must provde the Department with an emai address r they have one.The mats provided may be used(or
official communicator wth the!cermet.However emal addresses are pubk record.If you do not wish to supply a personal address,please provde the Department wth an email
address which can be made available to the pubk.To determine f you are a kensee under Chapter 455,P.S.,please click bese.
Product Approval Accepts:
®®®121
vccuuit•w tk ,
Credit SArrrh��FE
OFp/C
�cOP}
2 of 2 3/7/2013 9:33 AM
CURRIES Door Product Information and Installation Instructions
General Information
1) Product is qualified for Large and Small Missile Impact.
2) Product meets the requirements of the High Velocity Hurricane Zone.See below for water
infiltration requirements
3) Doors qualify for water infiltration where the overhang(OH)ratio is equal to or more than 1. The
over hang ratio shall be calculated by the following equation:OH ratio=OH Length/OH Height.
Max. Max. Min.
GroupDesign Door Series Door Size Door Glazing Hardware
Pressure And Swing Gauge
PSF
3'0"x 7'0" Cylindrical Lock; Mortise Lock;
1 50 607,707 Single 20 NONE Rim Exit
Out-Swin
607,707, 3'0"x 7'0" Glasslam, Concealed Vertical Rod;
2 60 727,747, Single 18 Polycarbonate Cylindrical Lock, Mortise Lock;
or 847 Out-Swing or Louver Mortise Exit; Rim Exit;
Surface Vertical Rod
607, 707, 3'0"x 7'0" Glasslam,
3 60 727,747, Single Cylindrical Lock; Mortise Lock;
18 Polycarbonate
or 847 In-swing or or Louver Interconnected lock
Out-Swing
607,707, 6'0"x 7'0" Glasslam, Concealed Vertical Rod;
4 60 727,747, Pair 18 Polycarbonate Rim Exit;
or 847 Out-Swing or Louver Surface Vertical Rod
3'0"x 8'0" Glasslam, Concealed Vertical Rod;
5 60 707, 727, Single 16 Polycarbonate Mortise Lock(Latch Bolt and Dead
747,847 Out-Swing or Louver Bolt); Rim Exit;
Surface Vertical Rod
707, 727, 3'0"x 8'0" Glasslam, Mortise Lock(Latch Bolt and Dead
6 60 747,847 Single 16 Polycarbonate Bolt)
In-Swing or Louver
Concealed Vertical Rod;
707 727 6'0"x 8'0" Glasslam, Mortise Lock(latch bolt and dead
7 60 Pair 16 Polycarbonate bolt)active,Surface Bolts inactive;
747,847 Out-Swing or Louver Rim Exit;
Surface Vertical Rod
3'0"x 7'0" Mortise Lock(Latch Bolt and Dead
607,707, Glasslam,
Bolt);, Cylindrical Lock with Cylindrical
8 70 727,747, 18 Polycarbonate
or 847 In-swing or or Louver Dead Bolt;
Out-Swing Interconnected Lock
Concealed Vertical Rod;
707, 727, 4'0"x 8'0" Glasslam, Mortise Lock(latch bolt and dead
9 70 747,847 Single 16 Polycarbonate bolt);
Out-Swing or Louver Rim Exit;
Surface Vertical Rod
707, 727, 4'0°x 8'0" Glasslam, Mortise Lock(Latch Bolt and Dead
10 70Single 16 Polycarbonate
747,847 Bolt)
In-Swing or Louver
6'0"x 7'0"
11 70 707, 727, Pair 16 None Mortise Lock(Latch Bolt and Dead
747, 847 In-Swing or Bolt); Flush Bolt
Out-Swing
RD0510r5 1 of 10 Used with FL11537
01/10/2011
Max. Max. Mtn.
Group Design Door Series Door Size Door Glazing Hardware
Pressure And Swing Gauge
PSF
6'0"x 7'0"
12 70 777 Pair 18 None Mortise Lock(Latch Bolt and Dead
In-Swing or Bolt);Flush Bolt
_ Out-swing
Concealed Vertical Rod;
707 727, 8'0"x 8'0" Glasslam, Mortise Lock(latch bolt and dead bolt)
13 70 747,847 Pair 16 Polycarbonate or active, Surface Bolts inactive;
Out-Swing Louver Rim Exit;
Surface Vertical Rod
757 3'0"x 7'0" Cylindrical Lock
14 100 (STC 46) Single 16 NONE Mortise Lock(Latch Bolt and Dead Bolt)
Out-Swing ,
707, 727, 3'0"x 7'0"
15 100 747, Single 18 NONE Cylindrical Lock
847,777 In-Swing or Mortise Lock(Latch Bolt and Dead Bolt)
Out-Swing
707, 727, 3'0"x 7'0"
16 100 747,847, Single 18 NONE Rim Exit
777 In-Swing or
Out-Swing
3'0"x 7'0"
757
17 115 (STC 46) Single 16 NONE Mortise Lock(Latch Bolt and Dead Bolt)
Out-Swing
3'0"x 7'0"
18 115 707, 727, Single 16 NONE Mortise Lock(Latch Bolt and Dead Bolt)
747,847 In Swing Or
Out-Swing
707, 727, 3 0"x 7 0"
19 115 747,847 Single 16 NONE Rim Exit
Out-Swing
4'0"x 8'0"
20 150 707, 727, Single 14 Vetrotech Keralite Multi-Point Lock
747,847 In-swing or Ultra IGU HI
Out-Swing
8'0"x 8'0"
21 150 707, 727, Pair 14 Vetrotech Keralite Multi-Point Lock active,
747,847 In-swing or Ultra IGU HI Surface Bolts inactive
Out-Swing
707, 727, 4'0"x 8'0" Vetrotech Keralite
22 150 747,847 Single 14 Ultra IGU HI Surface Vertical Rod Exit Devices
Out-Swing
707, 727 8'0"x 8'0" Vetrotech Keralite
23 150 747,847 Pair 14 Ultra IGU HI Surface Vertical Rod Exit Devices
Out-Swing
Additional Door Information
1) Curries 707 18 gauge 3'0"x 7'0"embossed doors are permitted.
2) Curries 70716 gauge CURRIStain doors are permitted, 115 psf maximum design pressure.
3) Door edges maybe CURRIES'"S"(Visible Seam), "N"(Seamless),or"T"(Seamless)
4) Door Undercuts:
a.)3/8"Maximum undercut for doors with vertical and concealed exit devices and 150 psf doors.
b.)3/4"Maximum undercut for all other doors not included in 4a above.
5) Cold rolled or Galvanized steel may be used,gauges as noted.
16 ga Stainless Steel 707 doors may be used.
RD0510r5 2 of 10 Used with FL11537
01/10/2011 Opp
FCoA
Y
Door Glazing Information
1.) Markar WLV60 Louver or Pemko LV-WS,or any louver with a valid FBC component approval are
permitted in doors with max design pressure of 60 or 70 psf.
Maximum louver size is 34°x 78"on 4'0"x 8'0'doors. Minimum stile is 6".
2.) CURRIES Type 2 or Type 3 Vision light kits are permitted for Glasslam impact rated glass
Maximum DLO size is 24"x 66',maximum DLO area per leaf is 1584 sq. in.at 60 psf.
Maximum DLO size is 32"x 42°, maximum DLO area per leaf is 1344 sq. in.at 70 psf.
Minimum stile and rail is 6".
3.) CURRIES Type 1 or Type 3 Vision Light Kit are permitted with approved polycarbonate
Maximum DLO size is 32"x 42°maximum DLO area per leaf is 1344 sq. in at 60 psf.
Maximum DLO size is 32"x 42"maximum DLO area per leaf is 1344 sq. in at 70 psf.
Minimum stile and rail is 6".
4.) CURRIES Type 8 Vision Light Kit may be used with Vetrotech Keralite Ultra IGU HI
Maximum Design pressure is 150 psf
Maximum DLO size is 10"x 30"maximum DLO area per leaf is 180 sq. in
Minimum stile and rail is 6".
5.) All glazing and louver cutouts require channel surround.
Hardware Information
Hardware,vision light kits,and louvers may be used with the products listed above.The components must
have a valid FBC Approval for use as a door component. Components used in the High Velocity Hurricane
Zone must have a valid FBC Product Approval or a Dade County Product Control Component NOA for use
in the High Velocity Hurricane Zone.
Group 1
Yale Cylindrical Lock:4600LN,4700LN
Mortise Lock:8800 Series Mortise lock
Rim Exit Devices:2100(F)WS
Group 2
Corbin Russwin Cylindrical Lock:CL3300,CL33800, CL3900 Series
Mortise Lock: ML2000, ML20800 Series
Rim Exit Device: ED5200S(A)x M107; ED5200S(A)x M107 x 9800 Series Trim
Surface Vertical Rod Device: ED5470(B)X M107
Sargent Cylindrical Lock:6500, 7 Line, 10 Line, 10G77, 11 Line
Mortise Lock: 7800,8200, R8200,8200 Profile Series
Mortise Exit:WS8900, 12-WS8900 Series
Rim Exit Device: HC8800, 12-HC8800, HC8800 Profile Series,12-HC8800 Profile Series
Concealed Vertical Rod: MD8600, 12-MD-8600
Securitron Cylindrical Unlatch: UNL
Mortise Unlatch: MUNL
Power Transfer:EPT, EPTL, CEPT
Ving Mortise Lock:Classic,US ANSI
Rim Exit Device: VC3000
Yale Cylindrical Lock:4800/4800LN, 5400/5400LN,eBOSS E5400LN Series
Mortise Lock:8800,eBOSS E8800 Series
Rim Exit Devices: 7150/7250M(F)WS
Surface Vertical Rod Device:7170(F)WS
RD0510r5 3 of 10 Used with FL11537
01/10/2011
e„F'Y
I
Group 3
Corbin Russwin Cylindrical Lock:CL3300, CL33800, CL3900 Series
Mortise Lock: ML2000, ML20800 Series
Sargent Cylindrical Lock:6500, 10 Line, 10G77
Interconnected Lock:7500 Series
Mortise Lock: 7800,8200, R8200,8200 Profile Series
Securitron Power Transfer: EPT; EPTL,CEPT
Yale Cylindrical Lock:4800/4800LN, 5400/5400LN, eBOSS E5400LN Series
Interconnected Lock:4800 Series
Mortise Lock:8800, eBOSS E8800 Series
Group 4
Corbin Rim Exit Devices: ED5200S(A)x M107; ED5200S(A)x M107 x 9800 Series Trim
Russwin Surface vertical Rod Device: ED5470(B)X M107
Sargent Rim Exit: HC8800, 12-HC8800,HC8800 Profile Series, 12-HC8800 Profile Series
Concealed Vertical Rod:MD8600, 12-MD8600
Securitron Power Transfer: EPT; EPTL,CEPT
Yale Rim Exit Devices: 7150/7250M(F)WS
Surface Vertical Rod Device:7170(F)WS
4:, Group 5 & 9
Corbin Mortise Lock: ML2000, ML20800 Series with latch bolt&dead bolt
Russwin Rim Exit Devices: ED5200S(A)x M107; ED5200S(A)x M107 x 9800 Series Trim
Surface vertical Rod Device:ED5470(B)X M107
Sargent Mortise Lock:8200, R8200,8200 Profile Series with latch bolt&dead bolt
Rim Exit:HC8800, 12-HC8800, HC8800 Profile Series, 12-HC8800 Profile Series
Concealed Vertical Rod: MD8600, 12-MD8600
Securitron Power Transfer:EPT;EPTL, CEPT
Yale Mortise Lock:8800,eBOSS E8800 Series with latch bolt&dead bolt
Rim Exit Devices: 7150/7250M(F)WS
Surface Vertical Rod Device:7170(F)WS
Group 6& 10
Corbin Mortise Lock:ML2000 Series with latch bolt&dead bolt
Russwin _
Sargent Mortise Lock: 8200, R8200,8200 Profile Series with latch bolt&dead bolt
Securitron Power Transfer: EPT, EPTL, CEPT
Yale Mortise Lock:8800 Series with latch bolt&dead bolt
RD0510r5 4 of 10 Used with FL11537
01/10/2011 OPp
CJ
Group 7& 13
Corbin Russwin Mortise Lock:ML2000 Series with latch bolt&dead bolt(active leaf);
988CR Surface Bolts(inactive leaf)
Rim Exit Devices:ED5200S(A)x M107, ED5200S(A)x M107 x 9800 Series Trim with
FE707A, FE708A,WS707AKM,or WS708AKM Mullion
Surface vertical Rod Device: ED5470(B)X M107
Sargent Mortise Lock: 8200, R8200,8200 Profile Series with latch bolt&dead bolt
(active leaf);988 surface bolts(inactive leaf)
Rim Exit:HC8800, 12-HC8800; HC8800 Profile Series 12-HC8800 Profile Series with
HC980, 12-HC980, HCL980 or 12-HCL9980 Mullion
Concealed Vertical Rod: MD8600, 12-MD8600
Securitron Power Transfer.EPT, EPTL, CEPT
Yale Mortise Lock:8800 Series with latch bolt&dead bolt(active leaf);
988Y Surface Bolts(inactive leaf)
Rim Exit Device:7150/7250M(F)WS with M200FWS or KRM200FWS Mullion
Surface Vertical Rod Device: 7170(F)WS
Group 8
Corbin Russwin Cylindrical Lock: CL3300 Series with DL3100 Series Dead Bolt
Mortise Lock:ML2000 Series with latch bolt&dead bolt
Sargent Cylindrical Lock: 10 Line Series with 480 Series Dead Bolt
Mortise Lock: 7800,8200,R8200,8200 Profile series with latch bolt&dead bolt
Securitron Power Transfer: EPT;EPTL,CEPT
Yale Cylindrical Lock:5400/5400LN Series with 3600 Series Dead Bolt
Interconnected Lock: 4800 Series
Mortise Lock:8800 Series with latch bolt&dead bolt
Group 11 & 12
Ey(
Corbin Mortise Lock: ML2000 Series with latch bolt&dead bolt(Active)
Russwin
Rockwood Flush Bolts: 556 WS(Inactive)
Sargent Mortise Lock: 7800,8200, R8200,8200 Profile Series, with latch bolt&dead bolt(Active)
Securitron Power Transfer: EPT, EPTL, CEPT
Yale Mortise Lock: 8800, R8200 8200 Profile Series with latch bolt&dead bolt(Active)
Group 14 & 17
Corbin Russwin Mortise Lock:ML2000 Series with latch bolt&dead bolt
Sargent Mortise Lock: 8200 Series with latch bolt&dead bolt
Cylindrical Lock: 11 Line
Yale Mortise Lock:8800 Series with latch bolt&dead bolt
Note: Continuous hinges, pivots, EPT's, and position switches may not be used with the
757(STC 46)door.
RD0510r5 5 of 10 Used with FL11537
01/10/2011
O'/C
Copy
1
•
CURRIES Three Sided Door Frame, Four Sided Door Frame, and Transom
Frame Product Information and Installation Instructions
GENERAL INFORMATION
I) Building walls must be designed to support and sustain loads developed by the door and
frame assembly and transfer loads to the building structure.
2) Rough opening material,by others,must be installed properly to transfer loads to the
building structure.
3) Anchoring or loading conditions not shown in these details are not part of this approval.
4) Anchor embedment to base material shall be beyond wall dressing or stucco.
5) Masonry"T",Pipe Spacer,wire,welded EWA,wood stud,or steel stud anchors required.
6) Wood density,G =0.55.
7) Anchors shall be as listed and spaced as shown in the table for each group of products.
8) Substitution of components must be in compliance with the current Florida Building Code.
FRA115E CONFIGURATIONS ALLOWED
Model Configuration Max Opening Design Impact
Wall Type Size(ft-in.) Load (ft-lbs)
(psf)
Hollow Metal, Single Swing Drywall. 4-0,8-0 +/-70 350 it
M,CM,G,CG Masonry
Hollow Metal, Single swing Drywall, 3-0,7-0 +/- 115 350
M,CM,G,CG Masonry
Hollow Metal, Single Swing with Readyset Frame Drywall, 3-0,7-0 +/-60 350
M,CM,G,CG (Single-point lock) Masonry
Hollow Metal, Single Swing with Readyset Frame Drywall, 3-0,7-0 +/-70 350
M,CM,G.CG (Single-point lock and deadbolt) Masonry
Hollow Metal, Standard Swing Pair,With or Drywall. 8-0,8-0 +/-70 350
M.CM,G,CG Without Hardware or Hollow Masonry
Metal Mullion
Hollow Metal. Single Swing with Sidelight. Drywall, 3-0*.8-0** +/-60 350
M,CM,G.CG Transom or Transom/Sidelight Masonry
(++)
{ Hollow Metal, Standard Swing Pair with Drywall. 6-0*,8-0** +/-60 350
M.CM.G.CG Sidelight,Transom or Masonry
Transom/Sidelight(++)
Hollow Metal, Window Frame(++) Drywall. 3-0***. 10-0 +1-60 350
M.CM.G.CG Masonry
Hollow Metal, Single Swing Drywall, 4-0.8-0 +/- 150 350
M,CM,G.CG Masonry
oPppc
copy
RD0568r5 Page 1 of 21 Used for
01/17/2012 FL11537
A
Model Configuration Max Opening Design Impact
Wall Type Size(fl-in.) Load (ft-lbs)
(PsO
I ,
Hollow Metal, Standard Swing Pair,With or Drywall, 8-0,8-0 +/-150 350
M.CM.G.CG Without Hardware or Hollow Masonry
I Metal Mullion
Hollow Metal, Four Sided Door Frame Drywall, 3-0,7-0 +/-60 350
,M,CM,G,CG Masonry
Hollow Metal. Four Sided Door Frame Drywall, 3-0,8-0 +/-60 350
M,CM,G,CG Masonry
Hollow Metal, Four Sided Door Frame Drywall, 3-0,8-0 +/-60 350
M,CM,G,CG Masonry
Hollow Metal, Four Sided Door Frame Drywall, 6-0,8-0 +/-60 350
M,CM,G,CG Masonry
Hollow Metal, Four Sided Door Frame Drywall, 8-0,8-0 +/-70 350
M,CM.G.CG Masonry
Hollow Metal, Four Sided Door Frame Drywall, 8-0,8-0 +/-150 350
M.CM.G,CG Masonry
Hollow Metal, Single Swing with Side Panel, Drywall, 4-0*,8-0** +1-150 350
M,CM,G.CG Transom or Transom/Side Panel Masonry
Hollow Metal. Standard Swing Pair with Drywall, 8-0.8-0** +1-150 350
M,CM.G,CG Transom Panel Masonry
*Width is size of door opening(jamb to jamb).Sidelights may be mulled to the frame to increase the width of the
opening.
**Height is size of door opening(header to floor/sill).A transom may be mulled to the frame to increase the height of
the opening.
***Width size of individual window frame.Multiple window frames may be mulled together to increase the width of
the opening.
+4 Glass for window,transom and sidelight frames must be Glasslam laminated glass with a 0.090 in.minimum inner
layer.Multiple frames may he mulled together to increase the width of the opening.
M=Double Rabbet frame for use in masonry walls,block walls,or welded to building structure
CM=Double Rabbet frame for use in wood or metal stud walls
G=Single Rabbet frame for use in masonry walls,block walls,or welded to building structure
CG=Single Rabbet frame for use in wood or metal stud walls
Frames for use in masonry walls,block walls,or welded to building structure may also be used for wood or metal stud
walls.
1-3/4 in.thick Curries metal door panels may be used to glaze window, transom and sidelight frames.Door vision
light frames and louvers may be installed in the 1-3/4 in.thick panels
RD0568r5 Page 2 of 21 Used for
01/17/2012 FL 11537
OFFICE OOPy
FRAME ANCHORING
MASONRY T AND MASONRY WIRE ANCHORS
CMU BLOCK AND THROAT OF FRAME
FILLED WITH 3000 PSI MORTAR
\\ MAXIMUM SHIM
\ /—` \ Q ` THICKNESS 0.25"
) -,.—"------7---71---) 1
MASONRY WIRE ANCHOR
0.165"DIA.MIN.I 16 GA(0.053"MIN) _
MASONRY r ANCHOR
i*>
OPERATING RANGE 3"-12'
WELDED PIPE SPACER AND WELDED EWA ACNHORS
EXISTING MASONRY OR POURED CONCRETE,3000 psi MIN. WOOD STUD
PIPE SPACER ANCHOR WITH 3/8'FLAT HEAD PIPE SPACER ANCHOR WITH 3/8"WOOD
EXPANSION HEAD ANCHOR BOLTS SCREW OR LAG BOLT
MINIMUM EDGE DISTANCE=4.00' MINIMUM EDGE DISTANCE=1.75"
MAXIMUM SHIM THICKNESS=0.25" MAXIMUM SHIM THICKNESS=0.25'
N
r. •v
` t a-
. I\ kg
..._ ..p..,
1
v
.[
I ,c a 4I
L:..... J•�. .
2.50" MIN. - v n I _-t___
2.50'MIN -------
16
--- 3.0'MIN --I
16 GA(0.053"MIN) 16 GA(0.053'MIN) _
PIPE SPACER ANCHOR EWA ANCHOR
•---, \ TO SUIT ^
TO SUIT . I JAMB DEPTH `'
JAMB DEPTH ��� \-/ Opp/
• \/ Copy
RD0568r5 Page 3 of 21 Used for
01/17/2012 FL 11537
11
THREE SIDED AND FOUR SIDED DOOR FRAME ELEVATIONS FOR FRAMES
RATED UP TO AND INCLUDING 150 PSF
- 100'MAX -- 48"MAX
96'MAX - _
100' 100"
Max MAX
96" 96'
MAX MAX
, I - -
t - I
96'MAX 11--- 48"MAX --I
't
II
104" 104'
MAX MAX
96" 96'
MAX , MAX
I)
I i
100"MAX - — 52"MAX ---,
Three sided door frames may be KD corner or lace welded. Four sided door frames must be face
welded.
CI-
copy
RD0568r5 Page 6 of 21 Used for
01/17/2012 FL11537
11
THREE AND FOUR SIDED DOOR FRAME UP TO AND INCLUDING 70 PSF
96"Max
100"WITH MULLION (100'Max w/Mullion)
96"MAX WITHOUT MULLION
•
104" 100'
MAX Max
96' I 96'
MAX MAX
!If IIy 1
1, — I 1i
104"WITH MULLION _
100"MAX WITHOUT MULLION •
Three sided door frames may be KD corner or face welded. Four sided door frames and mullions
must be face welded. Only doors ma be installed in 4 sided door frames.
JAMB ANCHOR REQUIREMENT TABLE
THREE SIDED AND FOUR SIDED DOOR FRAMES UP TO AND INCLUDING 70 PSF
ANCHORS ANCHORS IN MASONRY"T"
FOR STEEL MASONRY OR WIRE
OPENING STUD MAX. W/ITH 3/8"DIA. MAX. ANCHORS, MAX.
HEIGHT OR WOOD STUD SPACING EXPANSION SPACING OR WELDED SPACING
WALLS SHELL ANCHOR TO BUILDING
BOLT STRUCTURE
80"—88" 4 22 4 24 4 24
90" 5 22 4 24 4 24
92"—96" 5 22 5 24 4 24
115 PSF THREE SIDED AND FOUR SIDED DOOR FRAMES(MAX OPENING WIDTH 3'0")
80"—88" 5 21 4 24 4 24
HEAD&SILL ANCHORING REQUIREMENTS FOR PAIRS OF DOORS IN THREE&FOUR SIDED DOOR FRAMES
UP TO AND INCLUDING 70 PSF
QUANTITY
ANCHOR TYPE OF LOCATION
ANCHORS
4
ANCHORS
FOR STEEL STUD
2 located on each side of the centerline of the head
OR WOOD STUD WALLS @ 9"and 12" from the centerline of the head
ANCHORS IN MASONRY W/3/8 2 1 each located 9"from the centerline of the head
EXPANSION SHELL ANCHOR BOLT
WELDED TO BUILDING STRUCTURE 2 1 each located 9"from the centerline of the head
RD0568r5 Page 7 of 21 UsQi
01/17/2012 FL11537 (,;®p"
JAMB ANCHOR REQUIREMENT TABLE FOR 150 psf THREE&FOUR SIDED FRAMES
QUANTITY MAX
ANCHOR TYPE OPENING WIDTH OPENING HEIGHT OF SPACING
ANCHORS
Up to and including 4'0" Up to and including 7'0" 6 12"
ANCHORS
FOR STEEL STUD Up to and including 3'6" Up to and including 7'6" 7 12"
OR WOOD STUD
WALLS Over 3'6"and Over 7'6°and 8 12"
up to and including 4'0" up to and including 8'0'
ANCHORS IN Up to and including 4'0" Up to and including 7'6" 4 24"
MASONRY W/3/8
EXPANSION SHELL Up to and including 4'0" Up to and including 8'0" 5 24"
ANCHOR BOLT
MASONRY"T"OR Up to and including 4'0" Up to and including 8'0" 5 24"
WIRE ANCHORS
WELDED TO
BUILDING Up to and including 4'0" Up to and including 8'0" 4 24"
STRUCTURE
HEAD&SILL ANCHORING REQUIREMENTS FOR PAIRS OF DOORS IN 150 PSF THREE&FOUR SIDED
DOOR FRAMES
QUANTITY
ANCHOR TYPE OF LOCATION
ANCHORS
ANCHORS 4 located on each side of the centerline of the head
FOR STEEL STUD 8 @ g", 12". 15",and 18"from the centerline of the head
OR WOOD STUD WALLS
ANCHORS IN MASONRY W/3/8 4 2 located on each side of the centerline of the head
EXPANSION SHELL ANCHOR BOLT @ 9"and 12"from the centerline of the head
WELDED TO BUILDING STRUCTURE 2 1 each located 9"from the centerline of the head
pOP),,
RD0568r5 Page 8 of 21 Used for
01/17/2012 FL11537
Frame Construction Corner Details—Three-sided and Four sided Frames
I,) Three sided door frames may be KD or Face welded
2.) Four sided door frames and transom frames must be face welded
KD CORNER
KD CORNER �\
s �a
FACE WELDED FACE WELDED
'' �KD CORNER KD CORNER
•
FACE WELDED
CORNIER
Lop/c
RD0568r5 Page 14 of 21 Used for
01/17/2012 FL11537
GLASSLAM GLAZING INSTRUCTIONS—VISION LIGHT KITS IN 1-3/4" PANELS—CONT'D
14)Apply 1/8"x 1/2"closed cell foam glazing tape to the removable stop.
15)If there is plastic release on the foam glazing tape,pull the plastic release back about 2"
from each end of the foam tape. Pull the plastic release around the removable stop so it can
be grasped after placing the removable stop on the polycarbonate.
16)If there is paper release on the foam glazing tape,remove the paper. Spray the exposed
foam tape with a mild soap solution immediately before placing the removable stops
against the Glasslam.
17)Using the alignment marks,position the removable stops against the Glasslam.
18)Install and tighten the#6 x I-1/4"oval head TEK screws in the removable stops. Be careful
not to over tighten.
19)If the release is plastic,grasp the free end of the plastic release, and slowly pull the plastic
release off the foam tape that was applied to the removable stop.
20)Using the Dow Coming 995 silicone or other high quality silicone, apply a cap bead over
the closed cell foam tape on the exterior side of the door vision light kit.
Hinges
1) Any Steel Door Institute(SDI) Member hinge spacing is permitted.
2) Minimum hinge size is 4-1/2"x 4-1/2" Std. Wt. unless otherwise noted.
3) McKinney HG305, MCK-I2 HD,MCK-14HD, MCK-25HD; Markar FM100, FM200,
FM300,FM3500, FM100, or FMI 1 11; Pemko CFMSLF-HD continuous hinges are
permitted.
4) Approved continuous hinges and pivots are allowed.
5) Install butt hinges,continuous hinges, and pivots in accordance with manufacturer's
instructions.
Locks
I) Any SDI Member lock locations are pennitted.
2) Install latching hardware in accordance with manufacturers installation instructions
3.) 1"diameter preparations for door position switches are permitted.
4.) Door position switches that fit in a cutout measuring 1.25"x 4.875" may be used in
single 3'0" x 7'0" doors rated 60 psf or less.
5.) Securitron EPT, EPTL, and CEPT and Von Duprin EPT 2 and EPT 10 power transfers
may be used.
6.) Magnetic locks may be used in addition to the required latching hardware
RD0568r5 Page 20 of 21 Used for
01/17/2012 FL 11537 cop
Thresholds and Weather-strip
1.) Thresholds
McKinney Products Part Nos. MCK177, MCK181, MCK2005
National Guard Part Nos. 803, 804, 896,8315
Pemko Part Nos. 177, 181, 2005
2.) Weather-Strips
McKinney Products Part Nos. MCKS88,MCK303 (Use MCK303 with continuous hinges)
National Guard Part Nos. 160, 5050 (Use 160 with continuous hinges)
Pemko Part Nos. S88, 303 (Use 303 with continuous hinges)
Threshold Installation
#10 x 1-1/2'WOOD SCREW
OR
12" OC TYP —I-"' ~ 3/16"X1-1/4"TAP CON
5.25" —�-
•
TYPICAL THRESHOLD
MOUNTING DETAIL
THRESHOLD
NOTE: 118"CLEARANCE BETWEEN
THE BOTTOM OF THE DOOR
AND THE THRESHOLD IS
TYPICAL
Test Protocols Used
1) ANSI A250.13 Testing and Rating of Severe Windstorm Resistant Components for Swinging Door
Assemblies
2) ASTM E330 Standard Test Method for Structural Performance of Exterior Windows,Curtain
Walls,and Doors by Uniform Static Air Pressure Difference
3) ASTM E1886 Standard Test Method for Performance of Exterior Windows,Curtain Walls,Doors,
and Storm Shutters Impacted by Missile(s)and Exposed to Cyclic Pressure Differentials
4) ASTM E1996 Standard Specification for Performance of Exterior Windows,Curtain Walls,Doors
and Impact Protective Systems Impacted by Windborne Debris in Hurricanes
5) TAS 201-94, Impact Test Procedures
6) TAS 202-94,Criteria for Testing Impact and Non-Impact Resistant Building Envelope Components
Using Uniform Static Air Pressure.
7) TAS 203-94,Criteria For Testing Products Subject to Cyclic Wind Pressure Loading
4.7 COp
RD0568r5 Page 21 of'21 Used for
01/17/2012 FL 11537
•
Honda building Code Online help://www.floridabuilding.org/pr/pr_app_dtl.aspx?pararrx=wGEVXQ...
. ^,w•umyal.Tn,
Business & Professional Regulation
:;ti�•�•„��u SCIS Home Lop In ! User Reglstraton 1 Hot Topa ' Submt Sun:harge t Stets&Facts 1 Publcatnrts . FBC Stair BCtS Ste Map tanks Search
Busines
Professi6 'al USRd User al
GtMfee>fcrcn'.ty,Rrj�Lii la�y; pmdhur annitwiti Menti>Prnth t ar AM„Ar_.ron cant>Apyyatnn t At>Application Data
+j4/# ti FL# FL9481-R1 A
Application Type Affirmation
Code Version 2010
Application Status Approved
Comments
Archived
Product Manufacturer Hager Companies
Address/Phone/Email 139 Victor Street
Saint Louis,MO 63104
(314)633-2743
mmcrae@hagerco.com
Authorized Signature Mark McRae
mmcrae@hagerco.com
Technical Representative Mark McRae
Address/Phone/Email 139 Victor Street
Saint Louis,MO 63104
(314)633-2743
mmcrae@hagerco.com
Quality Assurance Representative Keith Williams
Address/Phone/Email 310 Hamrlc Drive West
Oxford,AL 36203
(256)831-9863 Ext 107
kwililams@hagerco.com
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Certification Mark or Listing
Certification Agency Intertek Testing Services NA Inc.-ETL/Warnock Hersey
Validated By Intertek-ETL/Warnock Hersey
Referenced Standard and Year(of Standard) standard Year
A250.13 2003
Equivalence of Product Standards
Certified By
I affirm that there are no changes In the new Florida Building Code
which affect my product(s)and my product(s)are in compliance with
the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity Yes No N/A /°y
Pp
Product Approval Method Method 1 Option A ®p
1 of 2 3/8/2013 3:15 PM
Honda Building Lode Online help://www.l]oridabuilding.org/pr/pr app dtl.aspx?pararn=wGEVXQ,..
Date Submitted 02/22/2012
Date Validated 02/22/2012
Date Pending FBC Approval
Date Approved 02/26/2012
Summary of Products
FL# Model,Number or Name Description
1..9481.1 14500 Series Panic and Fire Rated Rim
- —••-- Type Exit Hardware •
I Limits of Use Certification Agency Certificate
Approved for use In HVHZ:No FL9481 R1 C CAC Intedek Haaer Authority to Mark-4 9Q
Approved for use outside HVHZ:Yes series March 2009.odf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure:+70/-70 01/01/2020
Other:4'0"x 8'0"max,single-outswing door,350 ft-lb Impact Installation Instructions
rated FL9481 RI. II I-ED00119.PDF
FL9481 RI. II I-ED00789 REV2,011f
•
Verified By:Intertek Testing Services NA Inc.-ETL/Warnock
• Hersey
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
•
n
Contact rs;;igyp Norrb Monroe Street.Telahatcee FL 37391 Phone:950.457.1821
The State of Fbnda ban AA EEO employer.Cepyrbht 2007r2010 Stele of Fbnd ;;fn✓gv Statemep(:;Accessibdty Statem nt;; efund cmt m ret
Under Fbrlda mw,emal addresses are pubic records.U you do not want your emal address released in response to a pubic-records request,do not send electronic mad to the
errtty.Instead,contact the office by phone or by traditonal mat.i'you have any quest ons,pram contact 850 487.1395.'Pursuant to Secton 455.275(1).Horde Statutes,
effects/4 October 1,2012,lienees tensed under Chapter 455,FS.must provde the Department wth an emal address f they have one.The emeis provded may be used for
oticei communcalon wth the kersee.However emal addresses are pubic record.If you do not with to supply a personal address,please provele the Department wth an emad
address which can be made avawble to the pubic.To determne I you are a kersee under Chapter 455,F.S.,please tick hr.'
•
Product Approval Aarepta:
®®®MI
sccuritt•tt t'rhtr
CreditSAr_ct
FE
Opp
Opt
2 of 2 3/8/2013 3:15 PM
Report prepared for:Malt Lansdowne(Intertek)on 3/1912009 12:22:13 PM
Intertek
AUTHORIZATION TO MARK
This authorizes the application of the Certification Mark(s) shown below to the Product
Covered described below herein when made in accordance with the authorized Listing Report,
including Manufacturing/Machining Specifications, and under conditions set forth in the
Certification Agreement and Listing Report, including Manufacturing/Machining Specifications.
This authorization also applies to the Multiple Listee model(s) identified on the correlation
page of the Listing Report.
Client Number: 25763 Report Number: 3124955MID-008, 3149472MID-003,
3129572MID-010A
Evaluation Center: Intertek (Middleton)
Applicant/Basic Listee: Hager Companies (MO)
139 Victor Street
St. Louis, MO 63104
Mark Mcrae
314-633-2743
314-615-9933
Product Covered: Hager Model 4500 Fire Rim Exit Device with 4900F Keyed
Removable Mullion
Testing Standards: UBC 7-2 (1997) NFPA 252 (1999) CAN4 S104 (1985)
ANSI A250.13 (2003) UL 10C (R2001)
This document is the property of Intertek Testing Services and is not transferable. Only the
Applicant may reproduce this document. The Certification Mark(s) may be applied only at the
above noted location of the Party Authorized to Apply the Mark(s).
‘IcceRrFk
Xivis_114.111)us
•'hock T1et�
This document supersedes all previous Authorizations to Mark for the noted Report Number.
This Authorization to Mark is for the exclusive use of mtonok's Client and is provided pursuant to the Certification agreement between!Martel(and its Client Intertek's responsrohkty and Ihabilty
are limited to the terms and conditions of the agreement Intertek assumes no liability to any party.other than to the Client in accordance with the agreement.for any loss,expense or damage
ocasioned by the use of this Authorization to Mark Only the Client is authorized to permit copying or dislnbution of this Authorization to Mark and then onty in its entirety of'Modeles
Certification mark is minded to the conditions fait out in the agreement end in this Authorization to Mark Any furlher In of the tntenek name tot the sate or arise hl elreteala
d mania
product or service must first be approved In writing by Intertek Initial Factory Assessments and Follow up Services ere for the purpose of assuring appropriate usage of the den clip!,
Copy
Hager Companies(MO)118791 I Rev:Mar 19 20119 12:22PM I Uncontrolled Copy I DRAFT.NOT APPROVED Page 1 of 5 �"
•
•
Report prepared for:Matt Lansdowne(Intertek)on 3/19/2009 12:22:13 PM
accordance with the agreement.they are not for the purposes of produehon quality control and do not relieve the Client of the ohligabons in this respect.
Authorized By:
Bob Davison,Certification Manager
Menet Tesiarg Services NA,Inc.
8431 Murphy Drive,Middleton,WI 63562 LISA
Phone 608.824-7440 Fax 608.831-9279
o'%
•
Hager Companies(MO)118791 I Rev:Mar 19 2009 12:22PM I Uncontrolled Copy I DRAFT•NOT APPROVED Page 2 of 5
Report prepared for:Malt Lansdowne(Intertek)on 3/19/2009 12:22:13 PM
Listing Section(s): DOOR & FRAME HARDWARE
Description: FIRE RESISTANT HARDWARE PRODUCT
Hager 4500 Series Fire Rim Panic Exit Devices are used in
both double and single swing applications, and have the
following performace ratings:
Hager 4500 Series Single Swing doors maintain up to 3 hour
fire resistance ratings when married with approved fire doors
and installed in accordance with this listing, and design
pressure of+-70 psf.
Hager 4500 Series Double Swing doors with 4900F Keyed
Removable Mullion maintain up to 3 hour fire resistance ratings
when using approved fire doors and installed in accordance
with this listing.
HAGER MODEL 4500 FIRE RIM PANIC EXIT DEVICE WITH
4900F KEYED REMOVABLE MULLION
Approved for use in all listed 8080 pair fire doors up to 3 Hours.
Wood or Hollow Metal Door construction.
Steel Stud or Masonry wall construction.
LIMITATATIONS OF USE
Hager 4500 Series Fire Rim Panic Exit devices have a design
pressure are limited to maximum opening size of 4.0'width by
8.0' height when installed per the manufacturer's recommended
installation instructions, with the following ratings:
Design Load: ±70 psf
Impact Resistance: 350 ft-lbs
Door Stiffness Class:
opr.
Maximum Door Size 4.0' x 8.0' C�C
Op _
Hager Companies(MO)118791 1 Ree:Mar 19 2009 12:22PM I Uncontrolled Copy I DRAFT-NOT APPROVED Page 3 of 5
Report prepared for:Matt Lansdowne(Intertek)on 3'19/2009 12:22:13 PM
Configuration: Outswing
Hager 4500 Series Fire Rim Panic Exit devices maintain up to
3 hour fire resistance ratings when used in accordance with the
listed and published information for the Approved for use Fire
Door. Hager 4500 Sereies Fire Rim Panic Exit devices are
limited for use to double doors of 8.0'x 8.0'opening size
(8080), or 4.0'x 8.0'for single door applications, wood or steel
skin doors and frames; installed into wood, steel or masonary
construction.
Hager Companies(MO)118791 I Rev Mar 19 2009 12:22PM 1 Uncontrolled Copy 1 DRAFT-NOT APPROVED Page 4 of 5