Loading...
HomeMy WebLinkAboutBldg Permit #19-0341- 8801 Astronaut Blvd- 1/24/19•e r -Ezz ,�°s� CITY OF CAPE CANAVERAL 100 POLK AVENUE CAPE CANAVERAL, FL 32920 j i, "� JAN 2 4 2019 � r (321) 868-1220 phone (321) 868-1247 fax C..e`IB�Ew« buildingsforms@cityofcapecanaveral.org BUILDING DEPT e DOCUMENT SUBMITTAL Permit #: I / - 031/1 Date: /-2 IP/ 9 Site Address: 380 I AS/POV)4 t f b%vi From: 3�h �4.1/� - T/tr"ech A/�.., Ste.1� Je 3 Z l -9/y- 2 3 7s 1 ❑ ❑ * Inspections * ** ❑ Contractor/Owner Telephone SURVEYS Form Board Survey* ❑ As -built Survey >-'. 0. Foundation/Floor Elevation Survey* ❑ Final Survey for Lot Drainage will not be scheduled until all required agencies approve the survey. LlJ 0 PERMIT DOCUMENTS j,� is Revised Construction Drawings* ❑Revised plot plan If revision adds square footage, additional permits fees will be added based on the additional square footage. Additional fees may be charged by the One-stop Agencies Documents requested by Plans Examiner ❑ Documents requested by Zoning ❑ Documents requested by Lot Drainage i ❑ Documents requested by Utilities ❑ Documents requested by Fire . i. 3f A brief description is required: specify all documents and changes. Changes on plans should be identified by clouds. Unidentified changes will be returned. 944 f 14,0 -6,4,4,),yy. � .17,446/4 o)'1 l"ld waryyV, • is fo5e Ql, / 7 //e,e) 1 ° PRINTED NAME of person submitting documents SIGNATURE of person submitting documents OFFICE USE QNLY ❑ NOT ISSUED Accepted by: Jr!_ ISSUED Fees due: 0 T Collection # 1' FORM DATE: 3/29/2018 FORM: sBMTL CANAVERAL FIRE RESCUE Serving the city of Cape Canaveral &Canaveral Port Author' To: Mike German Building Official From: Jeff Roberts Fire Inspector Re: 8801 N. Atlantic_A. Suppression system revisions; Date: 01/29/19 I have reviewed the revised plans submitted for the suppressiontsyster►i a.t comments at this time =`Plansare approved as submitted with revisions, _> It is the responsi`bilit! antic and have no acceptance testing. Jeff Roberts Fire Inspector Canaveral Fire Rescue. Station #1: 190 Jackson Avenue •Cape Canaveral, Florida 32920 • (321) 783-4777 • Fax: (321) 783-5398 Station #2: 8970 Columbia Road *Cape Canaveral, Florida 32920 • (321) 783-4424 • Fax: (321) 783-4887 OFFICE COPY 'estaurant: Zarrella's Italian 8801 Astronaut blvd Cape Canaveral, FL. 3290 a Hoods 16' 'ire Equipment Contractor: Florida Alarm and Security Technologies 420 Manor Dr. Merritt Island, fl 32952 321-455-9377 AHJ : Cape Canaveral eview and approval by the AHJ shall not :lieve the applicant of the responsibility of )mpliance with FFPC1-1.14.4. unction test in accordance with NFPA 17. his is a pre engineered system. Piping will be ithin manufactures specifications. Actual pipe +ngths will be known after system is installed. ppliance brackets installed to insure proper !location of equipment under hood. 11 gas and electric appliances under hood will iut down upon actuation of system. .nly equipment that is referenced in the ianufacturers listed installation and maintenance ianual or alternate suppliers' components that -e listed for use with specific extinguishing /stem shall be used. fork done in accordance to NFPA #10(2013), 17A(2013), #96(2014), FFPC 6th (2017) edition, Ifrs. UL Specs. And all local codes and andards. )raven byt. Joseph Mullen • 11982 Nozzle 16416 Nozzles 11982 Nozzle 11982 Nozzle 11982 14178 14178 14178 11982 11982 11982 14178 1 Fryers(3) 21"x14" w/ Drip 2 Burner Range 4"x12" O cecic 4 Burner Range 24"x24" 6 Burner Range 36"x24" 6 Burner Range 36"x24" 6 Burner Range 36"x24" m Amerex --- KP 3.75, 3.75, 3.75 11.25 Gallon: 33 Flows available 24 Flows used 16416 (3) Nozzles/ 3 Flow/Up to 50" Perimeter inches of Duct (unlimited Length) 11982 (3) Nozzles/ 1 Flow/ up to 10' of plenum (area behind filters) 14178 (4) Nozzles/ 8 Flow points/ 18" to 50" above surface (4 Burner Range) 11982 (4) Nozzles/ 3 Flow Points/ 36" to 50" above surface (2 Burner Range) 13729 (2) Nozzles/ 4 Flow Points/ 36" to 48" above surface (Fryers) Piping within Manufacturers specifications Pull station located 10'-20' from hood in path of egress ga v (D y O 0 co- o m< ^3DcLo co O O - -FT 1._�,.m onge 36• "x270 t o Q-r7m as C momw�so co =111 -2= RI y a -o o �� Qr � o o � 8`zo o 9 <,o om a m 1 02 O * W 2`c v -'.a »mmCO3�o• cm®f�, o• m m CD , o z m m 0 -13 9,o03 1! 8c