Loading...
HomeMy WebLinkAboutBLDG PERMIT #10291 (fire sprinkler heads) bte:a 'x''24—/ CITY OF CAPE4/o5 / CANAVERAL Tracking# !3 — RECEIVE) BUILDING PERMIT APPLICATION Permit# 1 p 2 91 SEP ZS 1913 (321)868-1222 City of Cape Canaveral Building Department -7510 N.Atlantic Ave.-Cape Canaveral,FL 32920 You may download this application: www.cityofcapecanaveral.org. You may fax to: (321)868-1247. All applications must include the backside of this form. Important: Please complete the checklist on the back of this form and provide other documentation as indicated on the checklist. A copy of contract may be required. Application packages will not be accepted unless complete. APPLICANT WILL BE CALLED WHEN PERMIT IS READY (Contractor/Owner-Builder is required to sign for the building permit,unless indicated otherwise by affidavit. I.D.may be required) Address of Job Site: S 60/ i-70AJ4vi etvo. Zoning classification: Flood Zone: Legal description of property: TwN: RNGi SEC: SURD: BLK: t.OT: P13: Pc: Property Owner Name: t'X'ret91,16 Furl (ALL. Phone: Address: 11AS Co Cc,p B cl-(. LSA( Cc oa. 4 fit. Fee Simple Titleholder's Name(if other than owner): Address: Bonding Company: Address: Mortgage Lender: Address: J Type of Permit Brief description of work: Building Electrical Plumbing Mechanical v--Other ADO A-00 (k.L0C.A C-Yr Rcez, S?te(0(LCL-+2 I-44,4(oS Type of Square Const. Occu- FPL lines City Sewer #of #of #of #of #of Valuation of work Building Feet Type panty currently available Concrete/ stories dwel- bed- water under (IA, Classifies available to to serve Asphalt ling rooms closets (Copy of Contract Required) (Please roofserve this this VB, -tion Parking units indicate as etc) (B,R1,R3 property? property? Spaces applicable) etc.) Yes/No Yes/No vtOmmercial $ 2 045c_SFR $ t Townhouse $ Apartment $ Condominium $ Other $ Architect/Engineer Name: Name of Company: . Address: State License No.: Phone(office): Phone(cell/pager.): Fax: Primary Contractor Name: Name of Company: Address: State License No.: Phone(office): Phone(cell/pager.): Fax: Electrical Contractor Name: Name of Company: Address: State License No.: Phone(office): Phone(cell/pager.): Fax: Plumbing Contractor Name: Name of Company: Address: State License No.: Phone(office): Phone(cell/pager.): Fax: Mechanical Contractor Name: Name of Company: Address: State License No.: Phone(office): Phone(cell/pager.): Fax: Specialty/Other Contractor Name: 3o►.k-pi c otiA b.? Name of Company: C-1)(..&41\44 ft gee ( res-11c '), LC,(. Address: 30,(4 0 C. JlsL- ST (In ek.130JO Af 2 C?O4 State License No.: Iciii$4-n0O t _ Phone(office): I—9/4—Dg{ol Phone(cell/pager.):3ZI- 2$-2X.) Fax: Zo/tJ g21-"?3-3-12q1 I Building Permit Application Checklist Notes Completed Permit Application Current code edition:FL Bldg.Code 2010(as revised) Current survey showing all proposed construction and landscaping Check with Bldg.Dept.for setbacks Notarized signature—Owner/Builder Affidavit If owner is acting as contractor Sewer Impact Fee receipt May be deferred until C.O.Unless job is remodeling County Impact Fee receipt May be deferred until C.O. Capital Expansion Impact Fee receipt Maybe deferred until C.O. Sidewalk Impact Fee receipt If sidewalk exists on lot Recorded Warranty Deed/Proof of Ownership Copy of Recorded Notice of Commencement(over$2,500) Over$7,500 for Mechanical change out Current Cert.Of Liability Ins./Worker's Comp.Policy/Exemption Record will be kept on file after initial submittal Community Appearance Board Approval For all work visible from Public Right-Of-Way Planning and Zoning Board Site Plan Approval For all new construction of four units or more Concurrency Forms For all new construction not part of approved site plan Primary Contractor's State License Record will be kept on tile after initial submittal Subcontractor's Authorizations: Record will be kept on file after initial submittal State License Notify Building Department of contractor changes Plumbing Contractor Plumbing Contractor Electrical Contractor Electrical Contractor Mechanical Contractor Mechanical Contractor Roofing Contractor Roofing Contractor Swimming Pool Contractor Swimming Pool Contractor Gas Contractor Gas Contractor Specialty/Other Contractor Specialty/Other Contractor Construction Drawings: Per F.B.C. 104 Three sets of sealed construction drawings Per F.B.C. 104 Truss layout and reaction summary Cut sheets and shop drawings will be needed at time of insp. Electrical Load Calculations Plans must indicate person responsible for calculations Electrical Riser All new service must be located underground Plumbing Riser Plans must indicate person responsible for design A/C layout Plans must indicate person responsible for design Two sets of Energy Calculations Plans must indicate person responsible for calculations Lot Drainage Survey Four sets of Fire Suppression/Sprinkler/Alarm specifications Requires Fire Dept.approval prior to issuance of permit Pool Barrier Requirement Form(signed) Pool permits will not be issued without barrier Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. The Building Code in effect at the time of this application is the Florida Building Code 2010 Edition. I understand that all permits require inspections as indicated and that it is the responsibility of the permit holder to notify the building department when ready for inspection(s). This permit application is valid for six months from date of submission. By signing, applicant affirms that all above is true and correct and that he/she is an authorized agent of the Contractor/Owner and has the authority to apply for this permit. *ALL OTHER APPLICABLE STATE OR FEDERAL PERMITS MUST BE OBTAI • ' 1 ' • . II MMENCEMENT* '11 Contractor's Name: Co( Contractor's Signature: Date: 9-0( - /3 Site Address: go C_a CA✓el_ �' Nle1 . /—L For Notary use only: State of Florida,County of Brev rd —�� SwoRrn and subscribed before me this ZS— day of ,20/3 ,by JUII✓t cu Tel-Y/0,7 Printed name of Applicant who produced identification: or is personal •. , . 1,- .0',00., ,. . ', NotaryPublic State of Florida 49 . Cynthia Didt 4 _ Seal: .. ., � My Commission EE035267 ?or pot Expires 10/17/2014 Signature-Notary Public At Large This form may be duplicated. Address: .Ni. , BUILDING PERMIT FEES: Building Permit per square footage. 1 0 2 9 .1 Total Sq. Ft. (Living Area): Total Sq. Ft. (Enclosed Area): Building Permit based on valuation. 03t t "3 4- c '- Totaltal Sq. Ft. (Living Area): • Total Sq. Ft. (Enclosed Area): Building Permit miscellaneous. • Total Sq. Ft. (Living Area): Total Sq. Ft. (Enclosed Area): • Electrical Plumbing Mechanical • Building Permit Plan Check Fee • j4t - Fire Dept. Plan Check Fee e z Radon Trust Fund: sq. footage 1LP 4- : c- Concurrency Management Fee Capital Expansion Fee Total Building Permit Fees. k4q. z c SEWER PERMIT FEES: • Sewer Impact Fee Sewer Tap Fee Total Sewer Permit Fees • 2 -cot Thr• ' 57 Date: 3 • CANAVERAL FIRE RESCUE Serving the city of Cape Canaveral & Canaveral Port Authority Plan Review 10 2 91 To: Building Department Glenn Pereno, CBO From: John J. Cunningham, Fire Marshal_(�j Re: 8801 Astronaut Blvd., Unit— 103 �` Fire Sprinkler Changes Date: 10-15-2013 We have reviewed the plans and have no comments at this time. Plan Review Fee: $ 25.00 Station#1: 190 Jackson Avenue • Cape Canaveral, Florida 32920 • (321) 783-4777 • Fax: (321) 783-5398 Station#2: 8970 Columbia Road • Cape Canaveral, Florida 32920 • (321) 783-4424 • Fax: (321) 783-4887 www.ccvfd.org ; fp.3 e subway 321-799-2290 p.2 , YO?ICE OF CO C£R� 7 / PERil'D7'310. TAX FOLIO NO. STATE OF R.COW3.4 COUNTY OF MLitt THE 1.7vE3tSIGlv131)bczehy givms wake that improvement 713.Florida Suntans.the Collo ioaatiiors P i in the Notice of Ca einem proper�; in xcardttaee with Cha :Q t• DtsaiQvn ofpropty . e F ,r Ca a.` X./ of Z ply®d ar ea address if available) girt?/ Ale-O w a►.r?BA/ 2. L'cat+alax6ormation `)d 4 '.. 140.0.ee. -:' - -du" 3. Owner• a) Iced addt><gq- PesK a /C .v zi Name daeldrcss oifx - . � • e" - 4 i .- 3"tsa,. ;�u 4 c6ry y s�tilebo lifot3ser thw owaerk e s tom .. Arse 3 2 Q. 4. Coes r acsor(Nr mt and address) ' ire S 5. Smety --�-L.= .71`r, -',le,$r..�-/4 #0=.1., •?Z 93 7 a) Name and add b) Ammar ofIxisat 6. Lcodu(T1a and,----F------ 7. }_7. Persons within the&amofFlor'ds ctzsign3ted by Dano upon Rim23CitC5 crother doomones Smtiaa 713.13(I)(a)(7)Florida Stances(dame and address): �'be served as provided by IL In addition to himsem Cvir_er&si copy of c 11CaoG Notice a Bis o= Provided as Stxtioa 71,.13(1)(b),Deride to receive a 9. Fzp sa cra of dais ofnotice oa Q,t(be aP on dale is:rear ao�the dor of recording unless a different date is sPcCified): .- WARNING f10 OWNER:ANY PAYMENTS MADE BY WA OWNERI ANY M.E. TS THE OWNER A•�T:IT "TION OF THE NOTICE OF COMMENC�YI ES-T ARE YOUR PAYING PROP FOR ThiEN CHAPTER 713,PART f.scCTTON 713.13,FLORIDASTA.TUTES,AND CAN RESIJLTIN IMPROVEMENT'S TO YOUR PROTTATY. k NOTICE OF C POSTED OD!THE JOB SITE BEFORE THE FIRST INSPECTION.!F YOU 11 O•�tflL1CFX4JET.T MUST$'c RECORDED AND CONSULT ;YOUR�'D�tOR AN ATTORNEY BEFORE COMMENCING WORK C*RECORDING YO ern OF COX • SiguE e cf OwmCarO -T-7aAuthor:atd C►fecNDircooziPanac tntaager Managing member STATE OF FLORIDA 'ry OPBREV 5i�tntSrs Titirl0ffitoe The���sa, n�t,„s M �i -day of V tit�L., vary 06 he! / ins=orpen0oz es (typeern c � , mew/en fyq)for ofon Li0. yas mccatod) 5.:),..2_ . • �•.; MARIA DEL CARMEN VERA �GLd , ,r.� � ,�� f. ..� _ Ndary PuDtio- s�tr�t�txt=y —' State of Florida Pried,Type or Stamp�cmoissloned Dame of . ��` d My Comm.Expires Dee 14,2014 Cormniasaoci Nt:nsbtr Y p++biic °�a Commss on w EE 46587 /clonallyKIowa t/ aProtkimd IderaTioron Iluerpclatts61 Vtij,r5,1&sant timi 1 hot fad the brttomt,and Gal s x taco axod in n zc.rue:o Ow bot of Imo« Y 1raccseALdBcre. SQ.aent of%rant,t.GSM t Abe." CFN 2013159492.OR BK 6926 PAGE 1246 . • Recorded 07/18/2013 at 1 1:11 FLM.Scott Elks.Cleric of Courts.Brevard County #Pas1 Bulletin 014 RevH 11111111111111111111111111.1111111111111111.1111111111111111111111 W Rellaillim Model F1 FR Series c. Quick Response o IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIMMNIIOIIN Standard Spray Model F1FR56 Sprinkler Types Standard Upright Standard Pendent 'i '`" Conventional r .e" Vertical Sidewall Horizontal Sidewall - "`:i Model F1FR56 Recessed Sprinkler Types Upright Pendent Conventional Standard Pendent/F1/F2/FP _-- Horizontal Sidewall Model F1FR56 Concealed Sprinkler Types Standard Pendent Model F1FR42, F1FRXLH & F1FR28 Sprinkler , c.„,. Vertical Sidewall Horizontal Sidewall I 3ecessoci Standard Upright Pendent/F1/F2 Standard Pendent • — Model F1FR42, F1FRXLH & F1FR28 Recessed ''K qutu ',3-: ;10.• r:.:;' , Sprinkler Types . , Standard Pendent •, 7!: (f ` • 7 i' '.•:!;? """ c .° ,'2_ . . Listing & Approvals " 1. Underwriters Laboratories Inc. and Certified for Recessed Concealed Recessed Canada(cULus). Horizontal Sidewall Pendent Pendent/FP 2. Factory Mutual Approvals(FM) 3. Loss Prevention Council (LPCB, UK) _ 4. VdS Schadenverhutung GmbH •Wl ��,4 UL Listing Category ig_ ,� 914 Sprinklers,Automatic&Open(VNIV) Quick Response Sprinkler XLH Upright XLH Pendent XLH Recessed Product Description Pendent F1/F2 Reliable Models F1FR56, F1 FR42, FIFRXLH & F1FR28 At normal temperatures, the glass Series Sprinklers are quick response sprinklers which bulb contains the fluid in both the „n- combine the durability of a standard sprinkler with the liquid and vapor phases. The vapor ::> <. .'. attractive low profile of a decorative sprinkler. phase can be seen as a small bub- I The Models F1FR56, F1FR42, F1FRXLH & F1FR28 ble. As heat is applied, the liquid Series Recessed automatic sprinklers utilize a 3.0 mm expands, forcing the bubble smaller frangible glass bulb. These sprinklers have demonstrat- and smaller as the liquid pressure XLH Recessed ed response times in laboratory tests which are five to increases. Continued heating forces Pendent FP ten times faster than standard response sprinklers. This the liquid to push out against the bulb,causing the glass I quick response enables the Model F1FR56, F1FR42, F1FRXLH & F1FR28 Series sprinklers to apply water to to shatter,opening the waterway and allowing the deflec- tor to distribute the discharging water. a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled OFFICE amount of special fluid hermetically sealed inside a pre- copy cisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Bulletin 014 Rev. H • c Model F1 FR Series ier rie:.:11.:a b id Quick Response o Standard Spray 11111111.1111111111111111111111111111111111111111111111111111 i Model F1FR56 Sprinkler Types Standard Upright *'fr Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model F1FR56 Recessed Sprinkler Types 4 Upright Pendent Conventional Standard Pendent/F1/F2/FP --- Horizontal Sidewall "`y"' xr Model F1FR56 Concealed Sprinkler Typesall.t n ° `` _zx Standard Pendent if •,« -:{=--i xn•:.:, "4,?; Model F1FR42, F1FRXLH & F1FR28 Sprinkler ! Types Vertical Sidewall Horizontal Sidewall Recessed Standard Upright Pendent/F1/F2 Standard Pendent -- -- z ;A Model F1FR42, F1FRXLH & F1F1328 Recessed Sprinkler Types '� a;„ ,* —_ Standard Pendent r '' ' Listing & Approvals ►' + I 1. Underwriters Laboratories Inc. and Certified for Recessed Concealed Recessed Canada(cULus). Horizontal Sidewall Pendent Pendent/FP 2. Factory Mutual Approvals(FM) 3. Loss Prevention Council (LPCB, UK) 4. VdS Schadenverhutung GmbH UL Listing Category - Sprinklers,Automatic&Open(VNIV) Quick Response Sprinkler i XLH Upright XLH Pendent XLH Recessed Product Description Pendent F1/F2 Reliable Models F1FR56, F1 FR42, FIFRXLH & F1FR28 At normal temperatures, the glass :..; . Series Sprinklers are quick response sprinklers which bulb contains the fluid in both the combine the durability of a standard sprinkler with theliquid and vapor phases. The vapor %i-' attractive low profile of a decorative sprinkler, phase can be seen as a small bub- ; The Models F1FR56, F1FR42, F1FRXLH & F1FR28 ble. As heat is applied, the liquid Series Recessed automatic sprinklers utilize a 3.0 mm p expands, forcing the bubble smaller frangible glass bulb. These sprinklers have demonstrat- and smaller as the liquid pressure XLH Recessed ed response times in laboratory tests which are five to increases. Continued heating forces Pendent FP ten times faster than standard response sprinklers. This the liquid to push out against the bulb,causing the glass I quick response enables the Model F1FR56, F1FR42, F1FRXLH & F1FR28 Series sprinklers to apply water to to shatter,opening the waterway and allowing the deflec- tor to distribute the discharging water. a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled OFFICE amount of special fluid hermetically sealed inside a pre- U®Py cisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application . Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. Pintle (XLH Only) Deflector Load Screw Washer Bulb Frame / Cup mou•ge r 014FG06 Model F1FR42, F1FRXLH Upright Technical data: a Coefficient Response Max. Mln. Temperature Models Discharge ponse Size Working Working Rating Finish Pressure Pressure F1FR56 K 5.6 Fl FR42 Quick 1/2 NPT See Fl FR XLH K 4.2 Res onse Ratings"Table.(R1/2) 175 PSI 7 PSI "Temperature See p "Finish Table" Fl FR28 K 2.8 Material Data: Frame Deflector Load Screw PIntle Cup Washer Bulb CDA Alloy 260, CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 DZR Brass CDA Alloy 220 or or or coated with PTFE Adhesive Glass QM Brass or CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape CDA Alloy510 2. Model F1FR56, Upright, Pendent & Conventional Sprinklers Model F1FR42, F1FRXLH & F1FR28 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number (SIN) Orifice Size US Metric Height Organization Upright Pendent Standard-Upright(SSU)and pendent Deflectors Marked to Indicate Position 1/2'(15mm)(1) 1/2"NPT(R1/2) 5.6 80 2.25"(57mm) 1,2,3,4 RA14251 " RA14141' #'i 7/16"(10mm) 1/2"NPT(R1/2) 4.2 60 2.25"(57mm) 1 _ RA1423(1) RA1413 3/8"(10mm) 1/2" NPT(R1/2) 2.8 40 2.25"(57mm) 1 RA1421") RA1411 Conventional-Install In Upright or Pendent Position 15mm") 1/2"NPT(R1/2) 5.6 80 57mm 3, /. RA1475(3) I "'cULus listed corrosion resistant(Polyester coated)sprinkler. a)Polyester coated FM approved sprinkler. cal Polyester coated LPCB&VdS approved sprinkler RA1425, RA1414&RA1475. :fib: : Upright Pere Conventional Model F1FR56, F1FR42, F1FRXLH & F1FR28 Quick Response Recessed Pendent Sprinkler"' Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Thread K Factor Sprinkler Sprinkler Identification Number Orifice Size US Metric Height (SIN) 1/2"(15mm) 1/2" NPT(R'/) 5.6 80 2.25"(57mm) RA1414 7/16"(10mm) 1/2"NPT(R1/2) 4.2 60 2.25"(57mm) RA1413 3/8"(10mm) 1/2" NPT(R1/2) 2.8 40 2.25"(57mm) RA1411 ("Refer to escutcheon data table for approvals&dimensions I I r'r v2"RFdKYF 5/1-SIN fO J rt-- � , rn,aoucrP .a[w MINX ITwe ' 4-- 1Ir _T ]3/r6'P4t(58.70..) 10 1.0/ f1.o.[n90w I f —I`-( I rr L J { I u rva...v rrcriJ-•77>}u..J aa+a �'==F� INS a MOW q�� _ a FMIIM FfKf'-�pTa3•..1 -\ i� To 11/Cf or CEAVC �'- �Y/�O� �\ ■■ a r4.1.v NMI-3/47,9..4 -' l•!.0 ll I p4Ysgv 11 1 !..a... j,�—��7li Ar uawxw Rt[Y55. r-r/y7b^^J ra %�.i:1 l � u IUK..v Fratss.Laa3•.-1 � Fr YwwFw Frans- +T�r^•'••1 .r,..n-Frac.r/8 n. .Jk �- -,I ',=_z,,,, .r-i3iT •R"'J Vii AT r4YFF Y ncrss-9/)BT r�].-I lilt'IJ v'c"I� 9TSo.a..+. QViii� Z Yw"rYAY Frans- +T�s...-J A+I, n FFa x• r-/ePMa..•./ u JOSTMEY� ..-.—. 3 r/4-UN. rfl (a,.—,) MODELFIR LH. FIFR28 FP ..Kn MODEL F1FR56. F1FR42. Ft mail at F1FR28 F1 OR F2 O.KaOM • 56 F/FR42. FIFR% "SFPw.9F . —_r.TO.N/1•00040 MM r.r15/0•0.001rF Nal 111IPPFa1Ya IMM 11:1FSCIfl 0Y Model F1FR56, F1FRXLH&F1FR28 F 1 or F2 Model F1FR56, F1FRXLH&F1FR28 3 Sprinkler Types ' After installation,inspect all sprinklers to ensure that there is a gap Standard Upright ' between the cover plate and ceiling and that the four cup slots are Standard Pendent open and free from any air flow in edimert to the space above. Conventional Concealed cover plate/cup assemblies are listed orty for use with Recessed Pendent specific sprinklers. The use cf any other concealed cover plate/cup Vertical Sidewal I assembly with the Model F1FR56 Pendent Sp-hider or the we cf the Horizontal Sidewall Model CCP Concealed corer plate assembly ai any sprirllder with Recessed Horizontal sidewal I which it s not specifically listed my prevent good fire protection and Concealed pendent will void all guarartees,warrarties,listings and approvals. Maximum Working Pressure Glass bulb sprinklers have orange biib protectors to minimize 175 psi (12 bar) bib damage during shipping,handling and installation.REMOVE 100%Factory tested hydrostatically to 500 psi(34.5 bar) THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS Finishes(1) PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the Standard Finishes protectors before this time may leave the bulb vulnerable to dam- Sprinkler Escutcheon Cover platew age. RASCO wrenches are designed to install sprinklers when Bronze Brass covers are in place.REMOVE PROTECTORS BY UNDOING THE Chrome Plated Chrome Chrome Polyester Plated White CLASP BY HAND.DO NOT USE TOOLS TO REMOVE THE PRO- Coated(4)(3)(8) White Painted TECTORS. Special Application Finishes Temperature Ratings Sprinkler Escutcheon Cover plate"' Sprinkler Bright Brass t31 Bright Brass Bright Brass Max. Ambient Black Plated Black Plated Satin Classification Temperature Bulb Color `C °F Temp. Black Paint trot Black Paint Off White Ordinary 57 135 100°F(38°C) Orange Off White(2)(6i Off White Black Paint Ordinary 68 155 100°F(38°C) Red Satin Chrome Satin Chrome Black Plated Intermediate 79 175 150°F(66°C) Yellow ("Other finishes and colors are available on special order. Consult the Intermediate 93 200 150°F(66°C) Green factory for details.Custom color painted sprinklers may not retain their Hiqh(1) 141 286 225°F(107°C) Blue UL Corrosion resistance listing.Coverplate custom paint is semi-gloss, (1)Not available for recessed sprinklers. unless specified otherwise. (2) cULus Listed only. Escutcheon Data(1) (3) 200°F(93°C)maximum. ro SIN RA1435-cULus permits use with Fl,F2 or FP escutcheons for "light (4) cULus listed"corrosion resistance"applies to SIN Numbers RA1435 hazard"ally,while FM limits use for same hazard with F2 escutcheon cny. (HSW),RA1485(VSW),RA1425(Upright)and RA1414(Pendent)in standard black or white.Corrosion resistance in other polyester colors is Maintenance available upon request. The Model F1FR56, F1FR42, F1FRXLH and Model F1FR56, (5) FM Approvals finish as"Polyester coated"applies to SIN Number Fl FR42, Fl FRXLH&F1FR28 Recessed Sprinklers shotid be in- (6) 1414(Pendent)in standard black or white. spelled quarterly and the sprinkler system maintained in actor- OrderLPCBingd infodS provedfinishappliesonytoRA1425,RA1414andRA1475. dance with NFPA 25. Do not clean sprinklers with Specify: Information spr soap and water, Specify: ammonia a any other cleaning fluids. Remove c1 lst by usi ng a soft 1. Sprinkler Model brtsh or gertie va ut,fming. Remove any sprinkler which has been painted(other than fadaanyway.factory applied) 2. Sprinkler Type 3. Orifice Size of spare sprirtders should be maintained to allow quick replace- 4. Deflector Type rent cf darned a operated sprinklers. Prior to installation,sprin- 5. Temperature Rating Weis shoukJ be maintained in the original cartons and packaging 6. Sprinkler Finish to minimize the pctertial fa damage to sprinklers that would cause improper operation or non-operation. 8. Escutcheon Type 8. Escutcheon Finish(where applicable) 9. Cover plate Model 10. Cover plate Thread size 11. Cover plate Temperature 12. Cover plate Adjustment 13. Cover plate Finish Note:When Model F1FR56 Recessed sprinklers are ordered,the sprinklers and escutcheons are packaged separately. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fre Protecticn Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordnances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc (ii) Recycled eIiab ® (800)431-1588 Sales Offices Paper1 I (800)8431i-81505881 6051 Sales Fax Revision lines indicate updated or new data. (914)829 2042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.05/12 Pm19999070300 Bulletin 157 Rev.G Reliabl ® Model F3QR co 0 Quick Responsecn Dry Sprinklers Features _ 1. The Model F3QR sprinkler utilizes Belleville Spring Closure Technology. Reliable is the first in the industry to produce a Quick Response Dry Concealed sprin- - °— kler utilizing this technology. 2. Styles available ..k-H:'..... • Pendent • Recessed FP Pendent • Recessed Fl Pendent .•++� • Concealed Pendent • Horizontal Sidewall • Recessed FP Horizontal Sidewall • Recessed Fl Horizontal Sidewall 3. 11/2"(38m)escutcheon adjustment on pendent sprinkler. 4. '/z" (13mm)escutcheon adjustment on recessed sprin- = kler with push-on/thread-off FP Model Escutcheon ring. riff, 5. 3/8" (9.5mm) cover plate adjustment on concealedT sprinkler with push-on/thread-off CCP Cover Plate. �. 6. 3/4" (19mm) escutcheon adjustment on recessed sprinkler with Fl Escutcheon. r> _. 7. Attractive appearance. Employs 3mm frangible glass bulb and galvanized nipple. Recessed FP Pendent Concealed 8. Lengths available to accommodate installation di- mensions from 2" -to - 48" (51mm -to- 1219mm), in '/4" (6mm) increments. 9. Available in a variety of plated and painted finishes. 10.Polyester Coated Corrosion Resistant Sprinklers. US Patent Numbers 5,775,431 and 5,967,240. ; Approvals Ir r 3 1. Listed by Underwriters Laboratories Inc. and UL Cer- I` , titled for Canada (cULus) — `e+ Style Response Systn Type Hazard Pendent Recessed Fl Pendent Horizontal Sidewall Recessed Pendent Wet Pipe Light Recessed F1 Pendent Quick Dry Pipe Ordinary CCP Concealed All Preaction (R5714) Horizontal Sidewall Wet Pipe Recessed Horizontal Sidewall Std. Dry Pipe Light (R5334) All Preaction , "A."� 2. Certified by FM Approvals "'' Style Response S Sprinkler Typ® Hazards Pendent Wet Pipe Light `u , Y Recessed F1 Pendent Quick Dry Pipe Ordinary, (R5714) All Preaction Groups 1&2 Horizontal Sidewall Wet Pipe Recessed FP Recessed Fl Recessed Fl Horizontal Sidewall Quick Dry Pipe Light Horizontal Sidewall yorizontal Sidewall , (R5734) All Preaction ¢ FSCE 3. NYC MEA 258-93-E copy The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F3QR Dry Pendent Sprinkler in, Protrusion Elevated "A"Dim. 2"to 48"(51mm to 1219mm)in'/:'(6mm) increments Above bs ~'`at F`"` s, Finishes"' -l_• -- i4% Sprinkler Escutcheon •=_-3 b f', ,`_tib :::;Bronze Bronze Brass ; == L �� u System Tee Chrome Plated Chrome Plated I White Polyester a> White 1-NPT 2 1/8'Dia. lini ")Other finishes and colors are available on special order. (o.omm] -A-otmerolon Hak in Celsng IIII Consult factory for details. Adjustment Range '� rnkler in standard Black or 4'/4't-8.4mmi I 43/64' aa. cULus Listed as a Corrosion Resistant s P _, , 4 _31.emm I 1 White. illTotal Adjustment Sprinkle. Can i CdYng f 1 1/4'(31,8mm] Standard Temperature Ratings it II :=T-•j ,, I6,mm) Sprinkler Max Escatehton `-•Fo . c-rn,— Escutcheon Sprinkler Cti 1 Adjustmenl Claselfication Temperature Ambient Bulb Color �• --- '-7-----4 t Rating Temp. =y�J+ " 0 0 Nominal Position �jll 1 5/8- Ordinary 135°F (57°C) 100°F (38°C) Orange N Escutcheon l41•3nnnJ Ordinary 155°F (68°C) 100°F (38°C) Red �a�- - Intermediate(1) 175°F (79°C) 150°F (66°C) Yellow '/ao ,e] 3 Dia. Intermediate 200°F (93°C) 150°F (66°C) Green [76.2mml—..• 157R701-c High(') 286°F(141°C) 225°F(107°C) Blue Fig. 1 Sprinkler can and escutcheon fabricated of brass for better weather resistance in exterior applications. Note: The sprinkler can protrudes'/4"when escutcheon is in nominal position. Escutcheon adjustment ("Listed and Certified only by cULus. provides + 1/4" (+6mm) to -11/4" (-32mm) "A" dimension adjustment range. Sprinkler Guard: Model C-2 Sprinkler Installation Wrench: Model G3 Sprinkler Wrench Sprinkler Identification Number(SIN): R5714 Model F3QR Dry Recessed FP Pendent Sprinkler yy Inlet Protrusion Elevated - '--4— -r- --F,. "A"Dim. 3'/2"to 48"(89mm to 1219mm)in,/4"(6mm)increments Above Inside Pipe - r 44-:q- Finishes"' �,�___ n- - ii+r_�_�� 11^I I ti Sprinkler Escutcheon a =- t 1 —` ' System lee Bronze Brass i Chrome Plated at Chrome Plated 2 1/2Dia �j♦ ,•NP, White Polyester White [63.somm] ")Other finishes and colors are available on special order. •A• Dimension Hole in Ceiling in • Consult factory for details.Cup remands unfinished. �'°�*m/4 Range 2 19/64' Dia. Only the escutcheon will contain desired finish. (*6.35mm] [58.34mmJ c2,cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. Nominal Position Sprinkler Standard Temperature Ratings Il of Escutcheon Cup Assembly Sprinkler Max 9^ceain I C Escutcheon Claseiflcatlon Temperature Ambient Bulb Color al .....J c`".°� Rating Temp. 1/4'16.35mmJ I] --. Escutcheon Adjustment Ordinary 135°F (57°C) 100°F (38°C) Orange 1/4- (8.35mm) I Escutcheon3 7/32" Dio. Adjustment L .[81.76mm] Ordinary 155°F (68°C) 100°F (38°C) Red 1/2- 112.7mm] Intermediate(') 175°F (79°C) 150°F (66°C) Yellow Total Adjustment 15711w2-C Intermediate 200°F (93°C) 150°F (66°C) Green High(1) 286°F(141°C) 225°F(107°C) Blue Fig. 2 Sprinkler cup and FP Escutcheon fabricated of steel and recommended Note: Do not install the Model F3QR Dry Recessed FP for interior applications. Pendent Sprinkler in ceilings which have posi- "'Lleted and Certified only by cULus. tive pressure in space above. Sprinkler Installation Wrench: Model G3 R/C Sprinkler Wrench Sprinkler Identification Number(SIN): R5714 2. Model F3QR Dry Pendent Concealed Sprinkler "A"Dim. 3'h"to 48"(89mm to 1219mm)in 1/4"(6mm)increments tiici Protrusion Elevated =_- r.7-1----4---r-4:11 Above Inside Pipe - R CCP Cover Plate") Finishes `2' ` - - Standard Finishes Special Application Finishes li�— ti Chrome Plated Bright Brass Plated ._ ` 2 +/2put. System Tee White Black Plated � N Black Paint fl ' NP` Off White • Satin Chrome A•D;r„ension [63.50""] III Adjustment Rouge N04 In Ceamq ">Utilizes the 1/2"cover plate with 3/8"total adjustment. 4 3/16• Other finishes and colors are available on special order. i 4.76mm) 2 19/64'Dia.[56.342"] Consult factory for details. Nominal Position 0 Coverplote Spunkier mblY Standard Temperature Ratings ` Af4" ±,i Co+erolate Sprinkler Max. ^c`�n.; r, Assembly P Cover Plate T` — -a me-a cenh9, Classification Temperature Tem Ratin Ambient J _ Its_- P 9 3/16'(4.76mm]Rating Ternp. Dmemiole MustmenlOrdinary 135°F (57°C) 135°F (57°C) 100°F (38°C) coy/16"(ier,etmnJ Ordinary 155°F (68°C) 135°F (57°C) 100°F (38°C) ent [71-11Vi ( 1l mj Intermediate"' 175°F (79°C) 165°F (74°C) 150°F (66°C) 3/6•Adjustment Total Ad(uslmenl b31%;03-c Intermediate 200°F (93°C) 165°F (74°C) 150°F (66°C) High") 286°F(141°C) 1 165°F (74°C) 150°F (66°C) Fig. 3 Sprinkler cup fabricated of steel and CCP Cover Plate fabricated of Note: Do not install the Model F3QR Dry Concealed brass and recommended for interior applications. Pendent Sprinkler in ceilings which have posi- "'Listed and Certified only by cULue. five pressure in the space above. Sprinkler Installation Wrench: Model G3 R/C Sprinkler Wrench Sprinkler Identification Number(SIN): R5714 Model F3QR Dry Recessed Fl Pendent Sprinkler "A"Dim. 31/2'to 48"(89mm to 1219mm)int/4"(6mm)increments Finishes "' Sprinkler •Escutcheon Collar we c. [levo.. c___ -T - ----T-- _ A P Abov.Inside Pipe ,I„ 1 Chrome Plated Chrome Plated Chrome Plated tiNo _ White Polyester(2) White White ) r ti iii '"Other finishes and colors are available on special order. ._ _ ~ ' s,t`m'" Consult factory for details. i'� aall(2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or 2t63+/sc2-mma.]White. 4°.1n c.,x t'p r g I I 15/141- ...s.' Dimension [49 2mm) Adjustment Range Standard Temperature Ratings 4' I 3 6.35mml ,5,,6. Sprinkler Max Nominal Position [23.6mm] P Classification Temperature Ambient Bulb Color of Exuteheon cw A+xr Rating Temp. } } { �""^9_ 111—' ! ,/6 -'-6TI g (3.2mn) Ordinary 135°F (57°C) 100°F (38°C) Orange 1/4.16,351 i —ll,' Ordinary 155°F (68°C) 100°F (38°C) Red Escutcheon Ad[uslmenli ���/ 1/4'16.35)J Intermediate"i 175°F (79°C) 150°F (66°C) Yellow Escutcheon Adjustment Escutcheon • Intermediate 200°F (93°C) 150°F (66°C) Green +/r [,2.7—] High"' 286°F(141°C) 225°F(107°C) Blue Adjustrnent 2(72.2/32) "'°P°" "'Listed and Certified only by cULue. Fig. 4 Sprinkler Installation Wrench: Model G3 R/C Sprinkler Wrench Sprinkler Identification Number(SIN): R5714 OFFjGE CCPD 3. • Model F3QR Dry Recessed Fl Horizontal Sidewall Sprinkler ' "A"Dim. 31/2"to 48"(89mm to 1219mm)in'/:(6mm)incrementsr"—cea.n9•-i Finishes>" i.�r..-i/ 7 Exulchwn [3.2mm] Sprinkler Escutcheon Collar f_�� System lee S°rh.�kr Cup 2'(3O4.mm]Mor Chrome Plated Chrome Plated Chrome Plated bee^�y +?'[SOe.6mm]M°.. White Polyester(2) White White C\j 1 i • 1 1-NPT (.- I Other It d colors are available on special order. j=�p�y�'illlt�I 2 27/22' Consult factoryfor details. I. 11121144 I " [72.2mm (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or "'`�'= While. } N[leoIn I;I N°minoI Position Standard Temperature Ratings , 1,/16- 1.-.] of Escutcheon [.9.7mm] 1/4'[6.33] Sprinkler Max. Escutcheon Adjustment Classification Temperature Ambient Bulb Color ISA'007A A"OtrnensI°n 1/2 II2.7mmi +�Adjustment Rape Adjustment Rating Temp. 3'/'' Escutcheon Adjustment Ordinary 135°F (57°C) 100°F (38°C) Orange *• FOR FACTORY MUTUAL(FM) • 4" - lc FOR UNDERWRITERS LABORATORIES(UL) Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate(" 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green FIg. 7 High('> 286°F(141°C) 225°F(107°C) Blue • Listed by cULus for Quick Response.Approved by FM for Standard Response. ("Listed and Certified only by cULue. • Recessed Horizontal sidewall sprinklers are listed with cULus for installation of min. 4" (100mm) - to Sprinkler Installation Wrench: -max. 6" (150mm) belay ceiling and approved by Model G3 R/C Sprinkler Wrench FM for installation of min.4"(100mm)-to-max. 12" Sprinkler Identification Number(SIN): R5734 (300mm)below ceiling. Technical Data: Ordering Information Orifice Size: ''/2"(15mm) Specify: Thread Size: 1" NPT per ANSI B2.1 1. Sprinkler Type(select one): Working Pressure: 175 psi(12 bar) (a) Model F3QR Dry Pendent Nominal K Factor-US/(Metric):5.6/(80) (b)Model F3QR Dry Recessed FP Pendent Product Description (c) Model F3QR Dry Recessed Fl Pendent ReliableModelF3QRDrySprirlldersarequickresponsesprinklers (d)Model F3QR Dry Concealed Pendent ubliang a durable 3m frangible glass bib. This quick response (e) Model F3QR Dry Horizontal Sidewall enables these sprinkiers to apply water to a fire much sooner than (f) Model F3QR Dry Recessed FP Horizontal Sidewall standard response sprintders of the similar temperature rating. (g)Model F3QR Dry Recessed Fl Horizontal Sidewall Model F3QR Dry Sprmnkiersare intended for' in dryard p'ea> 2. Sprinkler Temperature Rating. tion systems and in areas subjected to freezing temperatures,such 3. Sprinkler Finish. as freezers and unheated portions inside and outside btildings. 4. Escutcheon type(F1 or FP). Environments wherein dry sprirtders are employed can be coy- 5. Cover Plate/Escutcheon Finish. relive.For this reason,Model F3 Sprinklers have a special wax fillet 6. Length: placed in the gap between the cup that supports the bulb and the "A"Dimension(face of tee to face of ceiling or wall)in V4° wrenching boss.This wax will not interfere with the operation cf the (6mm) increments. sprinkler, and it pre/tents cantaminents from entering the internal 7. Model F3QR Dry Pendent (a) is available without portion of the drop nipple.The wax must not be removed. sprinkler can and escutcheon. Operation The glass bulb consists cf an accrxately controlled amount ct Note: special kid hermetically sealed inside a precisely manufactured 1. The "A" dimension is based on a nominally gauged glass capsule. This glass bib is specially constructed to provide pipe thread "make-up" of 0.600" (15mm) per ANSI fast thermal response.When the ten-peratureincrcasessufficiently, B2.1 [7Y2threads approximately]. due to afire,the bulb shatters allowing cperatinxg parts to dear the 2. All platings and paintings are decorative and intend- waterway. This enables the inlet seal to release air a water and ed for interior use. subsequently, cause water flan/ over the deflector in a uniform spray pattern,cortrdling or extinguishing the fire. 5. .General Installation Instructions Maintenance Model F3QR dry sprinklers must be installed only in stan- The Model F3QR Quick Response Dry Sprinklers should dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) be inspected quarterly and the sprinkler system maintained pipe tees in the horizontal position,even at branch line ends. in accordance with NFPA 25. Do not remove the factory They should not be installed into elbows or pipe couplings applied thermally sensitive wax fillet between the bulb sup- located on drop nipples to the sprinklers. For these and porting cup and the wrenching boss. Do not replace this other fittings including CPVC*, the dry sprinkler should be wax with a substitute substance. An Alternate substance installed into a fitting to allow protrusion into the fitting in ac- may interfere with proper operation of the sprinkler. Do not cordance with the diagrams. The "A" dimension of the dry clean sprinklers with soap and water,ammonia or any other sprinkler,which extends into the freezers or a freezing zone cleaning fluids. Remove dust by using a soft brush or gently from wet pipe systems,should be selected to provide,as a vacuuming. Remove any sprinkler which has been painted minimum,the specified lengths in inches shown in Fig.8. (other than factory applied)or damaged in any way. A stock Caution: of spare sprinklers should be maintained to allow quick Do not install Model DH56 HSW Dry sprinklers into CPVC replacement of damaged or operated sprinklers. Prior to adapter fittings or tees that have an internal obstruction. installation, sprinklers should be maintained in the original This will damage the sprinkler and/or the fitting. Refer to cartons and packaging until used to minimize the potential Fig. 9. for damage to sprinklers that would cause improper opera- tion or non-operation. During installation,the following steps must be followed: 1. Cut the specified size hde(see illustrations)for the sprin- kler in the ceiling or wall directly in line with the tee. 2. Apply pipe joint compound to the 1" (25mm) pipe threads and install sprinkler using the Model G3 or G3 R/C Sprinkler Wrench as specified. 3. Install the Model FP push-on /thread-off escutcheon or CCP cover plate if required. Note: Installation of the Model F3QR Sprinklers is not rec- ommended in copper pipe systems,as this may reduce the life expectancy of the sprinklers. Model F3QR Concealed and Recessed In- stallation Instructions • The Model G3 R/C wrench (Fig. 10) is designed to locate on the wrenching pads of the recessed sprin- kler while centering in the cup. A standard 1/2" drive ratchet may be used to drive this wrench. Fig. 11 and Fig. 12 show sequentially the insertion of the wrench. First the wrench,with its jaws above the sprinkler de- flector, is moved laterally until centered with the cup. Then raise the wrench inside of the cup until its jaws engage the sprinkler's square wrenching pads (Fig. 12). To remove the wrench, follow this procedure in reverse order. Care should be taken to avoid striking the deflector,with the wrench. • Model G3 Wrench (Fig. 13) is used for installation of Pendent and Horizontal Sidewall sprinklers. • Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SER- VICE FOR FIRE PROTECTION. Removal of the pro- tectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PRO- TECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. OFFICE COPY 6. RECOMMENDED EXPOSED MINIMUM BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA (STANDARD DRY PENDENT SPRINKLER SHOWN) INSTALL I INCH NM THREADED END OF DRY PENDENT SPRINKLER WET PIPE INTO 714E 1 INCH NP1 SIDE OUTLET EXPOSED BARREL OF A MALLEABLE IRON TEE FITTING AMBIENT PER ANSI B 16.3 (CLASS 150) AMBIENT TEMPERATURE rti __ ___ s 7EMPERA7URE -- _ ___ OR CAST IRON THREADED TEE FITTING OF PROTECTED 40F/4'C I SOF/TOC I 60'F/16'C ' . - .r v PER ANSI 16.4 (CLASS 125) ONLY, AREA.A7 THE —1r- -—I—- -Ir--2 DISCHARGE END EXPOSED MINIMUM BARREL LENGTH.. 44 ,ry . OF THE SPRINKLER (FACE OF TEE TO TOP OF CEILING) `,�===�6DF--.i, rL-- ----; IN. (NM) IN. (MM) IN. (MM) Lr,1 1 tiJ IF HUMIDITY AND TEMPERATURE DIFFERENTIAL 40'1 (4'C) 0 0 0 / ~' CAUSES CONDENSATION ON THE EXPOSED DRY Ir SPRINKLER,CONSIDER WRAPPING THE EXPOSED 307 (-1•C) 0 0 0 BARREL WITH INSULATION. FOAM INSULATING TAPE OR EOUNALENT. 207 (-TC) 4 (101) 0 0 107 (-17C) 8 (203) 1 (25.1) 0 01 (-18'C) 12 (305) 3(75) 0 MINIMUM (HEATED AREA) SEAL THE CLEARANCE SPACE -10'( (-23'C) 14 (356) 4 (101) 1 (25.1) EXPOSED AROUND THE SPRINKLER 10 AVOID I�' BARREL LEAKAGE OF AIR INTO THE PROTECTED -207 (-217C) 14 (356) 6 (152) 3(75) LENGTH AREA AND CONSEQUENT FORMATION OF CONDENSATE AROUND THE FRAME. VHICH -30'! (-SCC) 16 (406) 8(203) 4 (101) COULD INHIBIT OPERATION OR CAUSE 11 PREMATURE OPERATION SEE BELOW FOR -40.1 (-41C) 18 (457) B(203) 4 (1oT) RECOMMENDED METHODS. CLEARANCE -507 (-46T) 20 (506) 10 (254) 6 (157) DIMENSION HOLE II -60'F (-51'C) 20 (508) 10 (254) 6 (152) •THE PROTECTED AREA REFERS TO THE AREA BELOW THE CEILING. I THE AMBIENT TEMPERATURE IS THE TEMPERATURE AT THE DISCHARGE ( �� I / /�/� END OF THE SPRINKLER. PROTECTED AREA TEMPERATURES THAT OCCUR BETWEEN TTHE E VALUES / ' LISTED. USE THE NEXT COOLER TEMPERATURE. __ ^THE MIN. REQUIRED BARREL LENGTH IS NOT THE SAME AS THE 'A' DIMENSION. CEILING `I���h ESCUTCHEON NOTE: EXPOSED MINIMUM BARREL LENGTHS ARE INCLUSIVE UP TO 30MPH WIND VELOCITIES IN THE PROTECTED AREA ",`, (PROTECTED AREA) =_ 3- DIA *RECOMMENDED EXPOSED MINIMUM BARREL LENGTHS ALSO APPLY TO HORIZONTAL SIDEWALL DRY SPRINKLERS* RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS WET PIPE (STANDARD DRY PENDENT SPRINKLER SHOWN) WET RIPE rt 11 -___ 1;, r:ti == h"===add--',p�_-- bft= I Lr-1 I 1J L. J IMM MN (HEATED AREA) (HEATED AREA) MINIMUM MINIMUM EXPOSED EXPOSED BARREL BARREL LENGTH DECKTITE FLASHING 1 INSIDE FACE SEAL LENGTH (SEE ABOVE) RASCO 14003910 /r (SEE ABOVE) (RECOMVENDEMNENDE D) / ////////. I I I///////� CLEARANCE HOLEI INSULATED FREEZER, OR COOLER STRUCTURE OR EXTERIOR FRAMING I q‘Mill=1P 1111.11=11. immill (PROTECTED AREA) DRY SPRINKLER (PROTECTED AREA) n'IJ!I+ DRY SPRINKLER liill IN COLD AREA �I`II�II IN COLD AREA fl '1)rmr Fig. 8 7. I C O Schedule- 10/Schedule-40 . . .. Fully Listed and FM Approved Sprinkler Pipe When you specify Allied Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (PA"-"-8") pipe and Sch-40 (1"-21/2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe Sch-40 Specifications Schedule-10/Schedule-40 product can be"hot-dip" NPS Nominal I.D. Wt. Wt.(H20 Filled) ERR galvanized to meet FM requirements for dry systems In;mm In;mm Lbs/Ft;kg/m Lbs/Ft;kg/m - in accordance with the zinc coating specifications of 1" 1.049 1.680 2.05 1 ASTM A-123. 25 26.6 2.5 3.05 - 1 r/4" 1.380 2.270 2.93 ® Superior Coating 32 35.1 4.36 4.36 - Our advanced formula mill coating offers a clean, 11/2" 1.610 2.720 3.61 1 durable surface. It is also paint-ready for custom 40 40.9 4.0 5.37 - color applications without special preparation. 2" 2.067 3.650 5.13 1 SO 52.5 5.4 7.63 ® American Made 2'/" 2.469 5.790 7.86 1 Able to meet "Buy American"requirement and is 65 62.7 8.6 11.73 - available through distributors in the USA,Canada, Mexico and Latin America. Sch-10 Specifications NPS Nominal I.D. Wt. Wt.(H20 Filled) CRR 0 Specifications & Approvals In;mm In;mm Lbs/Ft;kg/m Lbs/Ft•,kg/m Schedule-10/Schedule-40 pipe are in compliance 1/" 1.442 1.810 2.525 7.t ;55 with the following:ASTM A-135,Type E Grade A,and 32 36.6 2.7 3.75 - NFPA 13.All pipe products have a rated working 11/2" 1.682 2.080 3.04 5.6570 pressure of 300 psi maximum and also meet the 40 42.7 3.1 4.52 - stringent requirements for the following applications 2" 2.157 2.640 4.22 4.5827 and tests: 50 54.8 3.9 6.28 - • Welded Outlets 2'/" 2.635 3.530 5.89 3.5196 • Hydrostatic Pressure 65 66.9 5.3 8.77 - • Side Wall Rupture 3" 3.260 4.330 7.94 2.5550 75 82.8 6.4 11.82 - 4" 4.260 5.610 11.78 1.6020 100 108.2 8.3 17.53 - 5" 5.295 7.77 17.33 1.4874 125 134.5 11.56 25.80 - 6" 6.357 9.290 23.03 1.0251 150 161.5 13.8 34.27 - 8" 8.249 16.490 40.15 1.8365 200 209.5 24.5 59.75 - ® c® 41> APPROVED ©PP/C Cr) ie Customer Service (800) 882 5543 Fax: (800) 659 7730www.alliedtube-srin('�PFW��� � 16100 S Lathrop A:e. • 11350!lurc�rn Rd. •2525 N 27th Ave. •600 Dean Sfcvcn,[tic( TUBE & CONDUIT' Harvey,IL b0416 Philadelphia,P1 l',154 Phoenix,AZ 85009 ffarm Ile,PA 13067 C.I. THREADED FITTINGS STAR®PIPE PRODUCTS C E) U L LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 Cast iron threaded fittings are UL, ULC listed and factory mutual approved for 300 psi service.Gray iron per ASTM A126 class B. Dimensions conform to ANSI B16.4 class 125 except plugs conform to ASME B16.14.Threads are NPT per ANSI/ASME B1.20.1. - R ----._ n I i .7 i I e !r CAST IRON STRAIGHT TEE CAST IRON 90 DEGREE ELBOW NOMINAL ITEM MAX. DIMBJSIONS WEIGHT NOMINAL ITEM MAX. DIMENSIONS WEIGHT SIZE CODE WORKING EACH SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE (INCH) # P.S.I. A B PIECE 1 CT333 300 1.50 1.50 1.21 1 CB90033 300 1.50 1.50 0.95 11/4 CT444 300 1.75 1.75 1.87 11/4 CB90044 300 1.75 1.75 1.34 11/2 CT555 300 1.94 1.94 2.51 11/2 CB90055 300 1.94 1.94 1.80 2 CT666 300 2.25 2.25 3.96 2 CB90066 300 2.25 2.25 2.90 21/2 CT777 300 2.70 2.70 6.45 21/2 C1390077 300 2.70 2.70 4.75 ‘ J 1 :. CAST RON RED. COUPLING NOMINAL ITEM MAX. DIMENSION WEIGHT SIZE CODE WORKING EACH CAST IRON 45 DEGREE ELBOW (INCH) # P.S.I. A PIECE NOMINAL IT/N1 MAX. DIMENSIONS WEIGHT 1X1/2 CRC031 300 1.70 0.62 SIZE CODE WORKING EACH 1X3/4 CRC032 300 1.70 0.80 (INCH) # P.S.I. A B PIECE F 1 CB45033 300 1.12 1.12 0.84 1 1/4 CI345044 300 1.29 1.29 1.40 1 1/2 CB45055 300 1.43 1.43 1.80 / � f+ 2 C 845066 300 1.68 1.68 2.79 • l....__ 1 CAST IRON RED. 90 DEG. ELBOW NOMINAL ITBd MAX. DIMBJSIONS WBGHT .I i SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECEL i 1X1/2 CB90031 300 1.26 1.36 0.64 1X3/4 CB90032 300 1.37 1.45 0.87 CAST RON PLUGS 1 1/4X1/2 C 890041 300 1.34 1.53 0.96 11/4X3/4 C690042 300 1.45 1.62 1.13 NOMINAL ITEM MAX. DIMBVSION WBGHT 1 1/4X1 CB90043 300 1.58 1.67 1.16 SIZE CODE WORKING EACH 1 1/2x1 1/2 CB90051 300 1.41 1.66 1.17 (INCH) # P.S.I. A PIECE 1 1/2x3/4 C1390052 300 1.52 1.75 1.28 1/2 CPL001 300 0.94 0.10 1 1/2X1 CB90053 300 1.65 1.80 1.51 3/4 CPL002 300 1.07 0.17 1 1/2X1 1/4 CB90054 300 1.82 1.88 1.62 1 CPL003 300 1.25 0.28 2X1/2 CB90061 300 1.49 1.88 2.00 11/4 CPL004 300 1.36 0.44 2X3/4 CB90062 300 1.60 1.97 2.05 11/2 CPL005 300 1.45 0.62 2X1 CB90063 300 1.73 2.02 2.10 2 CPL006 300 1.56 0.91 2X1 1/4 CB90064 300 1.90 2.10 2.30 2X1 1/2 CB90065 300 2.02 2.16 2.60 Page 19 C.I. THREADED FITTINGS STAR®PIPEPRODUCTS ® FM LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON CROSS __1 , NOMINAL ITEM MAX. DIMENSIONS WBGHT SIZE CODE WORKING EACH • (INCH) # P.S.I. A B PIECE • 1 CX033 300 1.50 1.50 1.54 11/4 CX044 300 1.75 1.75 2.40 9 -1 11/2 CX055 300 1.94 1.94 3.10 2 CX066 300 2.25 2.25 4.00 1 1/4X1 CX043 300 1.58 1.67 2.05 1 1/2X1 CX053 300 1.65 1.80 2.40 2X1 CX063 300 1.73 2.02 2.75 e - • - CAST IRON REDUCING TEE L.- NOMINAL ITEM MAX. DIMENSIONS WEGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B C PIECE N 1X1X1/2 CT331 300 1.26 1.26 1.36 0.95 1X1X3/4 CT332 300 1.37 1.37 1.45 1.10 • ' 1X1/2X1 CT313 300 1.50 1.36 1.50 1.08 1X3/4X1 CT323 300 1.50 1.45 1.50 1.18 1X1X1 1/4 CT334 300 1.67 1.67 1.58 1.52 1X1X1 1/2 CT335 300 1.80 1.80 1.65 1.73 1 1/4X1 X1/2 CT431 300 1.34 1.26 1.53 1.17 1 1/4X1 X3/4 CT432 300 1.45 1.37 1.62 1.38 1 1/4X1 X1 CT433 300 1.58 1.50 1.57 1.47 1 1/4X1 X1 1/4 CT434 300 1.75 1.67 1.75 1.80 1 1/4X1X1 1/2 CT435 300 1.88 1.80 1.82 2.05 1 1/4X1 1/4X1/2 CT441 300 1.34 1.34 1.53 1.37 i 114X1 1/4X3/4 CT442 300 1.45 1.45 1.62 1.54 1 1/4X1 1/4X1 CT443 300 1.58 1.58 1.67 1.65 1 1/4X1 1/4X1 1/2 CT445 300 1.88 1.88 1.82 2.21 1 1/4X1 1/4X2 CT446 300 2.10 2.10 1.90 2.55 ' 1 1/2X1 X1/2 CT531 300 1.41 1.34 1.66 1.41 1 112X1 X3/4 CT532 300 1.52 1.37 1.75 1.65 1 1/2X1X1 CT533 300 1.65 1.50 1.80 1.65 1 1/2X1X1 1/4 CT534 300 1.82 1.67 1.88 2.00 1 1/2X1X1 1/2 CT535 300 1.94 1.80 1.94 2.30 1 112X1 1/4X1/2 CT541 300 1.41 1.34 1.66 1.58 1 112X1 114X314 CT542 300 1.52 1.45 1.75 1.72 1 112X1 1/4X1 CT543 300 1.65 1.58 1.80 1.85 1 1/2x1 1/4x1 1/4 CT544 300 1.82 1.75 1.88 2.22 1 1/2x1 1/4x1 1/2 CT545 300 1.94 1.88 1.94 2.45 1 1/2X1 1/4X2 CT546 300 2.16 2.10 2.02 2.80 1 1/2X1 1/2X1/2 CT551 300 1.41 1.41 1.66 1.76 1 1/2X1 1/2X3/4 CT552 300 1.52 1.52 1.75 1.87 1 1/2X1 1/2X1 CT553 300 1.65 1.65 1.80 1.94 1 1/2X1 1/2X1 1/4 CT554 300 1.82 1.82 1.88 2.29 1 1/2X1 1/2X2 CT556 300 2.16 2.16 2.02 3.28 2X1X2 CT636 300 2.25 2.02 2.25 3.40 2X1 114X2 CT646 300 2.25 2.10 2.25 2.80 2X1 1/2X1/2 CT651 300 1.49 1.41 1.88 2.09 2X1 1/2X3/4 CT652 300 1.60 1.52 1.97 2.40 2X1 1/2X1 CT653 300 1.73 1.65 2.02 2.54 2X1 1/2X1 1/4 CT654 300 1.90 1.82 2.10 2.85 2X1 1/2X1 1/2 CT655 300 1.49 1.41 1.88 2.24 2X1 1/2X2 CT656 300 2.25 2.16 2.25 3.75 2X2X1/2 CT661 300 1.49 1.49 1.88 2.60 2X2X3/4 CT662 300 1.60 1.60 1.97 2.71 2X2X1 CT663 300 1.73 1.73 2.02 2.97 2X2X1 1/4 CT664 300 1.90 1.90 "'Ft.-a 3.32 2X2X1 1/2 CT665 300 2.02 2.02 2.1Ir F �` -; 2x2x2 1/2 CT667 300 2.60 2.60 2.39 d .10 *�.:1,0I+r" Page 20 GROOVED COUPLINGS • ST,4R°PIPE PRODUCTSA, t® ► LISTED LISTED APPROVED _ For fire protection services request submittal GRS 1.3 The C-4 rigid coupling is designed for '4 rigid piping applications.Cast in place teeth bite into the pipe/fitting shoulder to pt` firmly restrict movement. +s C-4 RIGID COUPLING NOMINAL ACTUAL ULorFMMAX. MAX. ALLOW. NUTS/BOLTS DIMENSIONS-Inch/mm APPROX. SIZE PIPE WORKING END PIPE END (INCH) WEIGHT IN. SIIE P.S.I./' LOAD SEP. QTY. SIZE A B C EACH (mm) IN.(mm) (kPa) Lbs.(N) IN.(mm) Lbs.(Kq) 1 1/4 1.660 300 1623 0-0.06 2 3/8x2 4.20 2.55 1.70 1.48 32 42.2 2065 7219 0-1 5 107 65 43 0.7 1 1/2 1.900 300 2126 0-0.06 2 3/8x2 4.44 2.81 1.70 1.66 40 48.3 2065 9456 0-1.5 113 71 43 0.8 2 2.375 300 3323 0-0.06 2 3/8x2 1/4 4.88 3.28 1.76 1.85 50 60.3 2065 14781 0-1.5 124 83 45 0.8 2 1/2 2.875 300 4869 0-0.06 2 3/8x2 1/2 5.53 3.78 1.76 2.11 65 73.0 2065 21657 0-1.5 140 96 45 1.0 3 O.D. 3.000 300 5301 0-0.06 2 3/8x2 1/2 5.93 4.00 1.76 2.21 76,1 76.1 2065 23579 0-1.5 151 102 45 1.0 3 3.500 300 7216 0-0.12 2 3/8x2 1/2 6.38 4.40 1.76 2.41 80 88.9 2065 32097 0-3.2 162 112 45 1.1 4 4.500 300 11928 0-0.12 2 3/8x2 1/2 7.68 5.59 1.98 3.17 100 114.3 2065 53056 0-3.2 195 142 50 1 A 5 5.563 300 17014 0-0.12 2 1/2x3 9.06 6.93 2.06 4.50 125 141.3 2065 75678 0-3.2 230 176 52 2.0 6 6.625 300 24130 0-0.12 2 1/2x3 10.75 7.87 1.98 5.84 150 168.3 2065 107330 0-3.2 273 200 50 2.6 6.5 O.D. 6.500 300 23228 0-0.12 2 1/2x3 10.25 7.99 2.06 5.82 165.1 165.1 2065 103318 0-3.2 260 203 52 2.6 8 8.625 300 35056 0-0.12 2 5/8x3 1/2 13.44 10.21 2.22 10.82 200 219.1 2065 155929 0.3.2 341 13 56 4.9 10 10.750 300 45381 0-0.12 2 7/8x5 16.70 12.88 2.62 21.50 250 273.1 2065 201855 0.3.2 424 327 67 9.8 12 12.750 300 51071 0-0.12 2 7/8x5 1/2 18.50 14.89 2.62 27.36 300 323.9 2065 227164 0-3.2 470 378 67 12.4 1.Working pressure and/or end load are total allowable,based on standard weight steel pipe,roll or cut grooved. 2.One time field test pressure may be increased to 1.5 times the figures listed above. 3.Working pressures on other pipe schedules may be found on page 54. "Contact Star Pipe Products for actual listings on specific pipes • The C-3 coupling is a flexible light weight style which : is ideal for fire protection services and other services "y `<`;. where low pressure and ambient temperature conditions �;� ` are expected. L3 "art*,,. =`� C-3 LW FLEXIBLE COUPLING NOMINAL ACTUAL ULorFMMAx MAX. ALLOW. NUTS/BOLTS DEFLECTION DIMENSIONS-Inch/mm APPROX. SIZE PIPE WORKING END PIPE END (INCH) DEG.PER PIPE WEIGHT IN. SIZE P.S.I./' LOAD SEP. QTY. SIZE COUPLING IN./FT. A B C EACH (mm) IN.(mm) (kPa) Lbs.(N) IN.(mm) (mm/m) Lbs.(Kq) 1 1/4 1.660 300 649 0-0.13 2 3/8x2 4°-19' 0.90 3.82 2.53 1.65 1.16 32 12.2 2065 2887 0-3.2 75 97 61 42 0.5 1 1/2 1.900 300 851 0-0.13 2 3/8x2 3°-46' 0.79 4.06 2.78 1.65 1.16 40 18.3 2065 3785 0-3.2 66 103 71 12 0.5 2 2.375 300 1329 0-0.13 2 3/8x2 1/4 3°-01' 0.63 4.78 3.25 1.71 1.59 50 60.3 2065 5911 0.3.2 53 121 83 13 0.7 2 1/2 2.875 300 1948 0-0.13 2 3/8x2 1/4 2°-29' 0.52 5.29 3.75 1.71 1.82 65 73.0 2065 8665 0-3.2 43 131 95 13 0.8 3 3.500 300 2886 0-0.13 2 3/8x2 1/2 2°-03' 0.43 5.94 4.39 1.71 2.23 80 88.9 2065 12837 0-3.2 36 151 112 13 1.0 4 4.500 300 4771 0-0.25 2 1/2x2 3/4 3°-11' 0.67 7.68 5.81 2.06 4.42 100 111.3 2065 21221 0-6.4 56 195 118 52 2 0 6 6.625 300 10342 0-0.25 2 5/8x3 1/4 2°-10' 0.45 10.75 8.09 2.06 7.00 150 168.3 2065 16001 0-6.1 38 273 205 52 3.2 8 8.625 300 17528 0-0.25 2 3/4x4 1/4 1°-40' 0.35 13.44 10.43 2.06 13.00 200 219.1 2065 77965 0-6.1 29 311 265 52 5.9 *Contact Star Pipe Products for actual listings on specific pipes Page 5 • GROOVED FITTINGS ST. AR®PIPE PRODUCTS tiro 0 4:i► LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 "S"Series products are specifically designed for use in fire protection applications where economy is a factor.All products are UL &ULC listed as well as factory mutual approved. Maximum working pressure for these products is 300psi. :11 ii i:H.;..... ._. 9 IFIRE PROTECTION FITTINGS SK-1 GROOVED CAP SE-1 90 ELBOW SE-2 45 ELBOW ST-1 TEE NOMINAL END APPROX. NOMINAL CENTER APPROX. CENTER APPROX. CENTER APPROX. SIZE to WEIGH 7 SIZE to WEIGHT to WEIGHT to WEIGHT IN. END EACH IN. END EACH END EACH END EACH (mm) IN.(mm) Lbs.(Kci) (mm) IN,(mm) LbsArco) IN.(mm) Lbs.(KW IN.(mm) Lbs.0(c>) 1114 0.87 0.32 2 2.75 1.50 2.00 1.29 2.75 2.27 32 30 0.2 50 70 0.68 51 0.59 70 1.03 1112 0.87 0.39 40 30 0.2 2112 3.00 2.14 2.25 2.00 3.00 3.30 2 1.00 0.54 65 76 0.97 57 0.91 76 1.50 50 25 0.2 3 3.38 3.60 2.50 3.06 3.38 5.04 2112 1.00 0.75 80 86 1.63 64 1.39 86 2.29 65 25 0.3 4 4.00 5.78 3.00 4.89 4.00 7.86 3 1.00 1.23 100 102 2.62 76 2.22 102 3.57 80 25 0.6 6 5.50 11.78 3.50 9.95 5.50 19.05 4 1.06 1.95 150 140 5.31 89 4.51 110 8.64 100 27 0.9 8 6.81 21.10 4.25 15.40 6.94 33.30 6 1.06 4.58 200 173 9.57 108 6.99 176 15.10 150 27 2.1 8 1.19 8.98 Fittings are cast steel per ASTM A 958 or ductile iron per ASTM A536. 200 _ 30 4.1 SE-5 GROOVE X THREAD REDUCING 90 ELBOW NOMINAL MD. Thread A B Weight Siz - .. IN. (IN) (NPT) (IN) (IN) (lbs.) 1%x% 1.900 h-14 1.75 1.38 0.63 1%x V44 1.900 '/4-14 1.88 1.38 0.70 1'/2 x 1 1.900 1-11.5 2.03 1.50 0.80 2 x 6 2.375 ,-14 1.75 1.63 0.84 , I..\ 2 x'/4 2.375 %-14 1.88 1.63 0.93 1'I \ GA. 2 x 1 2.375 1-11.5 2.03 1.75 1.04 �� 2'r4 x'h 2.875 1.18%-14 1.75 1.81 � I� a 2%x% 2.875 %-14 1.88 1.81 1.30 Iln11 2'A x 1 2.875 1-11.5 2.03 1.94 1.50 A--.I "SPT SE-9 DRAIN ELBOW DIMENSION -WEIGHTS NOMINAL O.D. Thread C-E A Approx. Size (IN) (NPT) (IN) (IN) Weight IN. (lbs.) 2 2.375 1-11.5 2.75 2.16 1.70 2.5 2.875 1-11.5 3.00 2.16 2.45 3 3.500 1-11.5 3.38 2.16 3.50 4 4.500 1-11.5 4.00 2.25 5.25 id 6 6.625 1-11.5 5.50 2.25 14.00 • OFFICE COPyY «! Page 8 Loop Hangers Model #105 , __ _ :\ 304 Stainless Steel Swivel Loop Hanger APPLICATION: Pipe support for stationary stainless steel piping. H _ i N OTE: Swivel nut not furnished with hanger. Stainless steel hex nuts recommended for use with hanger. _ - 1 Part No. Pipe Gauge H W HS Finish* I Size 105005054 1/2 15 2-27/32 3/4 7/16 304SS 105007554 3/4 15 3-3/64 3/4 7/16 304SS 1050100S4 1 15 3-5/16 3/4 7/16 304SS 1050125S4 1-1/4 15 3-21/32 3/4 7/16 304SS 1050150S4 1-1/2 15 4 3/4 7/16 304SS 105020054 2 15 4-3/8 3/4 7/16 304SS 105025054 2-1/2 15 4-7/8 1 9/16 304SS 1050300S4 3 15 5-1/2 1 9/16 304SS 6 105035054 3-1/2 15 6 1 9/16 304SS 105040054 4 15 6-1/2 1-1/4 11/16 304SS 105050054 5 15 7-9/16 1-1/4 11/16 304SS 1050600S4 6 11 8-5/8 1-1/4 13/16 304SS 105080054 8 11 10-5/8 1-3/8 15/16 304SS Conforms With: Federal Specification WW-H-171 (Type 10), Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10), install in accordance with ANSI/MSS-SP-69. Model #115 R5 - Swivel Loop Hanger - NFPA '®a <• I31 ItIFO APPLICATION: Pipe support manufactured to use minimum �. rod sizes permitted by NFPA for fire sprinkler piping. �L NOTE: For 1/2" to 2", See Model #100 Page 48. I NOTE: Meets NFPA requirements. Part No. Pipe H CL RS MRI A Max. Recom. Finish* Size (NFPA) Load (lbs) 1150250EG 2-1/2 4-13/16 2-3/8 3/8 1 15/16 525 EG 1150300EG 3 5-5/8 2-7/8 3/8 1 1-1/8 525 EG 1150350EG 3-1/2 6-3/16 3-1/8 3/8 1 1-1/8 585 EG 1150400EG 4 6-13/16 3-1/2 3/8 1 1-1/4 650 EG 1150500EG 5 8-5/8 4-1/2 1/2 1-1/4 1-1/4 1000 EG 1150600EG 6 9-7/8 5-1/4 1/2 1-1/4 1-15/16 1000 EG 1150800EG 8 12-1/2 6-13/16 1/2 1-1/4 2-1/2 1000 EG Conforms With: Federal Specification WW-H-171 (Type 10), Manufacturers Standardization Society ANSI/MSS-SP -58 (Type 10), install in accordance with ANSI/MSS-SP-69. All dimensions are in inches unless otherwise noted. *See page 2 for finish and material descriptions. All material is Carbon Steel unless otherwise noted. Phone: 800-333-0852 • Fax: 800-677-5403 53 ERICO" www.erico.com I . Beam Clamps Model #300May be mounted •0 in either position. _ Domestic Beam Clamp ° sem. :-. r� Universal/Reversible (Double Rod Hole) �4 ;r Model #3001 -_ ;= **Import Beam Clamp :Qr. -r+r TOP BOTTOM 3 APPLICATION: Structural attachment (with infinite adjustment) to top or bottom of metal beams, purlins, channel or angle iron to support hanger rod. NOTE: Set screw must be tightened onto the sloped side of the I-Beam, channel or angle iron flange and torqued to 60 inch pounds. Set screw and locknut supplied are hardened steel. Available with a HD finish by special order. For corresponding retainer strap see Models 300C and 300R Part No. RS Max CL D MRI F T Max. Recom. Finish* Pipe Load (lbs) Size Top Bottom 3000037EG 3/8 4 7/16 1-1/8 1/2 3/8 3/8 500 250 EG 3000037PL 3/8 4 7/16 1-1/8 1/2 3/8 3/8 500 250 PL 3000050EG 1/2 8 9/16 1-1/16 11/16 1/2 1/2 950 760 EG 3000050PL 1/2 8 9/16 1-1/16 11/16 1/2 1/2 950 760 PL 3000062EG 5/8 8 9/16 1-1/16 11/16 1/2 1/2 950 760 EG 3000062PL 5/8 8 9/16 1-1/16 11/16 1/2 1/2 950 760 PL 3000075EG 3/4 8 9/16 1-1/8 13/16 5/8 3/8 950 760 EG 3000075PL 3/4 8 9/16 1-1/8 13/16 5/8 3/8 950 760 PL 3000087EG 7/8 8 9/16 1-1/8 13/16 5/8 3/8 950 760 EG 3000087PL 7/8 8 9/16 1-1/8 13/16 5/8 3/8 950 760 PL **30010037 EG 3/8 4 7/16 1-1/8 1/2 3/8 3/8 500 250 EG **30010037PL 3/8 4 7/16 1-1/8 1/2 3/8 3/8 500 250 PL Conforms With: Federal Specification WW-H-171 (Type 23), Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 19 & 23), install in accordance with ANSI/MSS-SP-69. Model #305 B-0-1 Steel Top Beam Clamp L.. APPLICATION: For attachment to the top of flange of structural H -''1BS� A shapes or for use under roof installations with bar joist type construction where the thickness of flange does not exceed 5/8". __L NOTE: Specify Carbon Steel or Stainless Steel (316). -� -10- RS 1.4- ; Part RS A B W H BS Max. Recom. Finish* No No. Load (lbs.) -4—W 3050037PL 3/8 3/4 31/32 1-13/32 1-21/32 3/8 500 PL 3050037S6 3/8 3/4 31/32 1-13/32 1-21/32 3/8 500 S6 3050050PL 1/2 3/4 29/32 1-15/32 1-23/32 3/8 1130 PL 305005056 1/2 3/4 29/32 1-15/32 1-23/32 3/8 1130 S6 Conforms With: Manufacturers Standardization Society SP-69 (Type 23). All dimensions are in inches unless otherwise noted. OFF/r. 'c COP *See page 2 for finish and material descriptions. All material is Carbon Steel unless otherwise noted. Y Phone: 800-333-0852 • Fax: 800-677-5403 17 ERIEEr www.erico.com �SCANNED City of Cape Canaveral Inter-Office Transmittal To: John Cunningham, Assistant Fire Chef From: Glenn B. Pereno, CBO Re: 8801 ASTRONAUT BOULEVARD, UNIT 103 We Transmit: ®Herewith ❑ In accordance with your request THE FOLLOWING: ®Plans ®Specifications ❑ Shop Drawings ❑ Prints ❑ Copy of Letter ®Information ❑ Other These are transmitted for: ®Permit Issue ❑ Record ❑ Information ®Approval I I Use ❑ Distribution ®Review & Comment ( ® ❑ ) Copies Date Description 4 9/27/2013 Fire Suppression System Alterations Remarks: 1,1 Copies to: By: Glenn B. Pereno