Loading...
HomeMy WebLinkAbout#19-0340 - 8801 Astronaut Blvd - 12/19/2018City of Cape Canaveral, Florida Building Permit PERMIT #19-0340 CUSTOMER #008941 PHONE: 321-868-1220 INSPECTIONS: 321-868-1204 FAX: 321-868-1247 PERMIT INFORMATION :LOCATION INFORMATION: Permit #: 19-0340 Issued:12/19/2018 Permit Type: MEC Cost: 10000.00 Total Fees: 232.44 Amount Paid: 232.44 Date Paid: 12/19/2018 Address:8801 Astronaut Blvd Cape Canaveral FL, 32920 PERMIT EXPIRATION DATE: 5/4/2019 CONTRACTOR INFORMATION ,. NER INFORMATION, Name: FL Alarm & Security Tech Inc Addr: 420 Manor Dr Merritt IsI, FL 32952- Phone: (321)455-9377 State Lic#: CMC1249856 Local Lic#: Name: Oshri Gal Address: 280 W Central Blvd Cape Canaveral, FL, 32920 Phone: (321) 783-1848 . .. _ APPI ICATIFIN.F.FFS BP -Main: 115.00 BP -Surcharge: 4.94 Plan Revision Fee: 0.00 Date Plan Revision Fee Paid: Temp CO: Concurrency: BP -Plan: 57.50 Fire Plan Review: 25.00 Plumbing: Electrical: Capital Expansion: After the Fact: 0.00 Re Inspection Fee Paid: 0.00 Mechanical: Sewer Imapct: Sewer Tap: SPECTIONS (for complete; list of required inspections, refer to Hard NOTE: Once an inspection is approved by an authorized inspector the permit expiration date is extended six (6) months from date of inspection. Permit Desc: INSTALL KITCHEN HOOD SYSTEM INSPECTION APPROVED BY: DATE: NOTICE: THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 6 MONTHS, OR IF CONSTRUCTION OR WORK IS SUSPENDED, OR ABANDONED FOR A PERIOD OF 6 MONTHS AT ANY TIME AFTER WORK IS STARTED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS DOCUMENT AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL. LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR ANY ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Sign & Date NdiDk /)i /k AUTHORIZED SIGNATURE / DATE ISSUED / DATE Print J55 -e, /10/l -int PRINT NAME 1 /1'5;/2215 ?!:33 pm moy47O I U LC: Cash 4LV ,IM Amount $0..00 mount res {0.cE 4 I.I • atioi Fee: '. 0.00:1 +, % CITY OF CAPE CANAVERAL o ,; s4+ ,t, Permit # j ♦ 4 i �ti' 100 POLK AVENUE 1- 1� CAPE CANAVERAL, FL 32920 Tracking # L NM 3 & (321) 868-1220 phone (321) 868-1247 fax Application Date: buildingforns@cityofcapecanaveral.org Permit Total- otalAPPLICATION APPLICATIONFOR BUILDING PERMIT Florida Building Code in effect: 6th Edition PROPERTY INFORMATION TWP: RNG: SEC: SUB #: BLKJPAR: NOV zos T. Site Address: 280/ rif roa1+K4. edvd e c, corwve4.4 32120 # Street City Zip Owner's Name: 1147 /t! ck-Velo •, > i" i' Lt C,, Last First Telephone Number Owner's Address: t80 1A/ ceei-lrai b/til Gov ecruv,,.1 32917 _ # Street City Zip CONTRACTOR'S INF9i(APPLICANT) • Qualifier Name: H Fi 40601- lit I2 `�,/ en �f? Last First License # Company Name: FLe ttt®p ALA 2M ,. 56...1•Ctcl►i'.t.i'y 1 U.-14 lit® i3O‹ ►EES Address: O iVL1rti-mof1... 412.1•1t Mi►2►Ztfl 1.54.^1.0 3L95"3- # Street City Zip Phone #: g 2.1- (15C -311 Fax #: E -Mail: ,Str04,y e_ SPP-LCoRSi e ie..Corn PROJECT INFORMATION ❑ Residential F4Commercial Site Plan #: Describe Work To Be Done: ledhet/ istAv It,fatw+ 4601 Cost of Project: $ /o, 417° Proposed Sq. Ft.: (copyof contract required) (total new construction) SUBCONTRACTOR INFORMATION: PRINT FIRST & LAST NAME i Plumbing: License #: Phone: ;• Electrical: License #: Phone: HVAC: License #: Phone: Rooting:. License #: Phone: Specialty: License #: Phone: FORM DATE: 3/26/2018 PAGE 1 of 2 FORM: APPL Site Address: Ci)8O ( 5 r Qfpq Au rte. 6 (\M Owner's Name: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE YOU SCHEDULE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Intl. ** NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county or that may be required from other governmental entities such as water management district, state agencies or federal agencies. APPLICANT'S AFFIDAVIT Application is hereby made to obtain a permit to do the work and installations as indicated. I acknowledge and accept responsibility for compliance with all applicable codes, regulations and ordinances as well as the payment of all legally constituted fees regarding this development application, including but not limited to ALL REVIEW FEES, PERMIT FEES, IMPACT FEES AND RESERVATION FEES. g, J/{co3 47.R0 Name (Pri )/: caner/Agent/Contractor II DISCLAIMER: The City of Cape Canaveral's approval of this development permit does not create any right for the I Signator : Owner/Agent/Contractor Date: /0/22//S permittee to obtain a permit from a state or federal agency. Further, pursuant to section 166.033, Florida Statutes, the City of Cape Canaveral shall not be liable for issuance of State of Florida County of Brevard Subscribed and sworn to before me this c=4,2 day this development permit in the event a permittee fails to obtain any other required approval, fails to fulfill obligations imposed by a state or federal agency, or undertakes actions that result in a violation of state or of Z� ,0��/0 personally �� federal law. appeared -, kle.(12cidCalrt1( The issuance this development is expressly who i e ona Juaown-ta-me or-produced Aik as identification, of permit conditioned upon the permittee obtaining all other applicable state o,federal permits, if any, prior to the commencement of and did at t. - an oath. i the development authorized by the City's development permit. 1•d 1r ' / .jsr Notar --, Seal .:.. .•A ::'is% CAROL BENNETT =44• ?°' _rr IL .a_ MY COMMISSION $ FF 228074 V-trr'f - • EXPIRES: July 31 2019 ,); , Bonded Thor Notary Public Underwriters Mt INSPECTION IS NUMMI) Failure to obtain a final inspection may result in a penalty. FORM DATE: 3/26/2018 PAGE 2 of 2 FORM: APPL J Florida Alarm Et Security Technologies 420 Manor Dr. Merritt Island, FL 32952 321 -455 -9377 - DATE September 7, 2018 EXPIRATION DATE 90 DAYS Zarrella's Italian E Wood fired pizza 8801 Astronaut Blvd Cape Canaveral, FL 32920 SALESPERSON JOB PAYMENT TERMS DUE DATE Joseph Mullen Hood Install See Below N/A QUANTITY DESCRIPTION UNIT PRICE LINE TOTAL 1.00 Installation of new 6' grease removal hood with built in air box 15,400.00 15,400.00 New exhaust and supply fans with curbs. Expansion and relocation of existing fire suppression system. Not Included: any needed Electrical, Plumbing(Gas), Roofing, drywall, etc. Payment Terms: 50% deposit, 40% upon completion(pre-final), 10% after final Ask Us About Financing. - PLEASE READ BEFORE ACCEPTING: The proposed work will be performed in accordance with NFPA and applicable state and local codes. We assume no further liability in the performance of the equipment as such malfunction may occur due to circumstances beyond our control. I hereby certify that 1 am capable of authorizing all work and payments for work herein described. I understand that by signing this I am relieving Space Coast Fire and Safety, Inc. of any further burden of responsibility outside of the described work. My legal fees or collection costs associated with non-payment will be the sole responsibility of the customer as directed by oral jurisdiction. Past due balances are subject to interest at 1.5%Monthl are net 1 f = he date of completion unless expli ' y describ To accept this quotation, sign here and retuu r �/"" Print Name: SUBTOTAL $ SALES TAX TOTAL 15,400.00 --^' 1,078.00 $ 16,478.00 -k 104_ (P..9 -r# 1-/-q-0 CWod� 5L o FQ P-4 `i;'O•c outee e ti This Instrument Prepared By. Name. Address: L� Permit No.; NOI1CDOF COMMENCEMENT State of (76'.'Ll County of err/tea' THE UNDERSIGNED bereby gives notice that improvement(s) will be made to certain real property, and in accordance with Chapter 713, Florida Stabiles, the following itfformation is provided inthis Notice of Cormmencernent Descc�ttan of property (legal d ription of property and street address). Qdeiwe, v" eo/ Jlfr��nn+r diva! ; Gnr'e' ee� aiF l f ft . vo 2. General desmiptianofimprovement 0 Of /si7--t....-+ hold Tax Folio No: 1. 3. Informatia))NName oplete address: `r JO \k 1 evc).10 p v i`tA- L f-C,� , \M b) Interest in property: OI' c) Name and address afFee Simple Title Holder (if other than owner): 4 CottractorInformation: F/oma, .Lr 4e -ex'', f S�ritrr: �Y s/qy,� a) Company name and completr address b) Phonenamben 3LIQ 4'Jf-%'317 Fax Number. eiyg ynav}or Or is/..v4, it 3r. °'f L 5. Surety: a) Nana and complete address %' b) Amot ofBond_ $ c)- nue-cumber- -- Fax Number 6 lender. b) b) Thor address and complete AIA e number: Fax Nurohm: 7. Peronswithin the State afFIorida designated by Owner upon wbom notices a -other dcntuneats maybe served as provided by m Section 713.13(1)(a)7 FI a) Name and complete address Froclvtaaba b) Phone manber 8. In addition to himselZAwnerdesignates the following persaa(s)to receive acopy oftheLienar'sNotice as provided in Section 713.13(1)(b), Florida Stn es a) Name and complete addres / / tr FaxNrmmber b) Pioneatben 9. Expiration date ofNotice of Commencement (the expaation date is 1 -year nom dm date ofrecording, unless a different date is specified): WARNINGTO OWNEIb MY PAYMENTS NADEBY TBE OWNER AFTER TETE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER MATER TIE, PART LSECTION 77:3.T3. FLORIDA STATUTES, AND CAN RESULT IN YOURPAYING TWICE FOR IMPROYEEIEZIT5 TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUSUBERECORDED AND POSTED ONTETE JOB SITE BEFORE THE ETRST INSPECTION. IFYOU INTEND TO OBTADi FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMNIENCINGWORK{ORRECORDINGYOURNO «' 0. COMMENCEMENT. , // 11,--- -- Simrahae of Owner or Owner's Authorized Ofcer1D rec tor/Partaer/Manager Signatory's Title/Office ..,\Ci1V.illn.0 The romping instrument was acknowledged before me this _n day oftype by (1`-'@"1t if -1611 (name of person as the LAr11•.1 in‘ tdi SoS)a'r�ra'r afer2rrority,..e.g. Officer. trustee, attorney, in fact) for 1(A'Vri iii U(name of party on behalf of whom instrument was executed). 1 - 1 f f7Y f ' (1'- ( (•{�`('.�/ Signal= ofNomrjr Public -State ofFlon"da Type, or Stamp Commissioned Name of Notary PublidCommissi nNU ober Personally Known " or Produced ID on Pussvm+t to Section 92425, Florida Statutes Under penalties of perjury, I declare thatl have reed the foregoing and that the facts stged in it are true to the best mfmy knowledge and belief (yy��Y(JJyi Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager °. {b.. DIANAVALERIARODRIGUEZ • MY COMMISSION # GG 129913 71 EXPIRES: July 31, 2021 Ali?!g: `' Bonded firm Notary Public U Od 0 00 r u) W 0 N C O Q 00 03 ro ON o ui N 0 — ca o 0 opo W r N z 8 g� U cc 0 CANAVERAL FIRE RESCUE Serving the city of Cape Canaveral & Canaveral Port Authority To: Mike German Building Official From: Jeff Roberts Fire Inspector Re: 8801 Astronaut Hood Plans Date: 11/19/18 I have reviewed the hood plans submitted for 8801 Astronaut unit 103 and have the following comments: • No interlocking heat sensor is shown in the plans for this hood. • Does this new hood tie into the existing hood, and if so how? • Is the exhaust duct manifolded to theexisting. hood? • Does this 6'. hood have its own make-up air fan and: exhaust fan or is it sharing component (s) with the existing hood. Jeff Roberts Fire Inspector Canaveral Fire Rescue —Ee- .25.00 Station #1: 190 Jackson Avenue •Cape Canaveral, Florida 32920 • (321) 783-4777 • Fax: (321) 783-5398 Station #2: 8970 Columbia Road •Cape Canaveral, Florida 32920 • (321) 783-4424 • Fax: (321) 783-4887 Restaurant: Zarrilla's 8801 Astronaut Blvd. Cape Canaveral Fl. 32920 Fire Equipment Contractor: Florida Alarm and Security Technologies 420 Manor Dr. Merritt Island/ fl 32952 321-455-9377 Mechanical License Holder Roger Jacob Harrell License: Cmc 124-9856 Typical Hood Installation Detail -1 Make -Up Air 10' minimum Exhaust Fan RoofnDeck Non combustible Barrier between Duct and wood wall Drop Ceiling 2 Hour rated duct wrap If needed see attached Info. Stainless Sheeting Restaurant: Zarrella's Italian 8801 Astronaut blvd Cape Canaveral, FL. 32920 Fire Equipment Contractor: Redat ,z f a tart a arad qtr t Tetima les 4 11 LntrI. Inerrittlaw* .i'l33 52 3214155-9377 AHJ : Cape Canaveral Review and approval by the AHJ shall not relieve the applicant of the responsibility of compliance with FFPC1-1.14.4. Function test in accordance with NFPA 17. This is a pre engineered system. Piping will be within manufactures specifications. Actual pipe lengths will be known after system installed. Appliance brackets installed to insure proper relocation of equipment under hood. All gas and electric appliances under hood will shut down upon actuation of system. Only equipment that is referenced in the manufacturers listed installation and maintenance manual or alternate suppliers' components that are listed for use with specific extinguishing system shall be used. Drawn by Joseph Mullen To Banquet Room Rest rooms Automatic gas valve Suppression system Storage + Prep Dining Room Ma in Entrance EXHAUST RISER HANGING ANGLE 20' CAP TRATE SOLO FILTER WITH HOOK 3' INTERNAL STANDOFF IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. GREASE DRAIN WITH REMOVABLE CUP LEFT QUARTER END PANEL 54' BACK SPLASH 122.00' HIGH X 102.00' LONG 1 L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE) FIELD WRAPPER 16.00' HIGH (SEE HOOD OPTIONS TABLE) ATTACHING SUPPLY RISER WITH VOLUME DAMPER PLATES 23.57. OPEN STAINLESS P3 4'} STEEL PERFORATED PANEL 48.0' MAX EQUIPMENT BY OTHERS 24' NOM. 80' SECTION VIEW - MODEL 5424ND-2-PSP-F HOOD - #> (E todrue#111 AM % I = -= JOB ZarrIlla LOCATION MERRITT ISLAND, FL, 32952 DATE 7/24/2018 JOB 3485537 DIYC REV. 1 3 DRAKIV BYreg41 SCALE 3/8' = 1'-0' Ta 54' v I U.L. Listed P.• 10' ole. %// L55 Series E26 Canopy Light Fixture - High Temp Assembly n ^ tility Cab! • - * , 28' 28' .... O1 �i/� � 0' 8' 10' ��%%// %/%2 1 8'® 16' -- 12' 36' 36' 21 42' O'Nom./6' 6' 0.00'0D 7' 080' Overall Length PLAN VIEW — Hood #1 6' 0.00" LONG 5424ND-2—PSP—F 00.2* A AM LP/Wit1V JOB Zarrilla LOCATION MERRITT ISLAND, FL, 32952 DATE 7/24/2018 JOB # 3485537 DWYC#2 REV. DRA/YN BYreg41 SCALE 3/8' = 1'-0' HOOD HOOD NO INP'UHMATICIN TAG MODEL — Jo0#341003/ LENGTH MAX' COOKING TEMP. EXHAUST PLENUM SUPPLY HOOD CONSTRUCTION HOOD CONFIG. TOTAL EXE. CFM RISER(S) END TO END ROW WIDTH LENG. HEIGHT DIA. CFM VEL. S.P. CFM 1 SIZE ND-24PSP-F 6' 0' Deg. 1410 20' 16' 4600' 12' 1410 1795 -0.696' 1120 430 SS Where Exposed ALONE ALONE HOOD HOOD NO. INFORMATION TAG FILTER(S) LIGHT(S) .-,•..•.,, WIDTH UTILITY CABINET(S) FIRE SYSTEM TYPE FIRE SYSTEMHANGING PIPING HOOD WGHT TYPE QTY.HEIGHT CFM LENGTH EFFICIENCY @ 7 MICRONS QTY. TYPE WIRE GUARD LOCATION SIZE ELECTRICAL MODEL # SWITCHES QUANTITY TYPE SIZE I 0.148' Ceptrete Solo Filter 4 20' 16' 85% See Filter Spec, 2 L55 Series E26 NO Left 12'x54'x24' SC-111110FP 1 Light 1 Fan NO 489 LBS IIUUu HOOD NO. yr- IJ..'' TAG ) OPTION ..,. LENGTH .-,•..•.,, WIDTH F--' HEIGHT TYPE 1 WIDTH FIELD WRAPPER 16.00' High Front, Left DIA. CFM S.P. 1 BACKSPLASH 122.00' High X 102.00' Long 430 SS Vertical 84' 16' 6' LEFT QUARTER END PANEL 23' Top Width, 0' Bottom Width, 23' High 430 SS DR HOOD NO. ,,Arn•s+, TAG .,,, POS. ..,. LENGTH .-,•..•.,, WIDTH F--' HEIGHT TYPE RISER(S) WIDTH LENG. DIA. CFM S.P. 1 Front 84' 16' 6' MUA 10' 28' 564 0.148' MUA 10' 28' 564 0.148' SPECIFICATION. CAPTRATE GREASE -STOP. SOLO FILTER THE CAPTRATE GREASE -STOP SOLO FILTER IS A SINGLE -STAGE FILTER FEATURING A UNIQUE S -BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR BAFFLE DESIGN, TO DELIVER EXCEPTIONAL FILTRATION EFFICIENCY. FILTER IS STAINLESS STEEL CONSTRUCTION, AND SIZED TO FIT INTO STANDARD 2 -INCH DEEP HOOD CHANNEL(S). UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO COMPONENTS WHEN ASSEMBLED. GREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE PARTICLES FIVE MICRONS IN SIZE, AND 85% GREASE PARTICLES SEVEN MICRONS IN SIZE AND LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE. THE CAPTRATE GREASE -STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2519-05. EFFICIENCY \'S. PARTICLE DL6DlITIB 2 PAR] CLE DIAMETER 4. m) CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH,. NFPA #96 NSF STANDARD 02 UL STANDARD #1046 INT. MECH. CODE (IMC) ULC -0649 PRESSUREDHOP \ S. FLOW BATE sea toa FLOW RATE (cfe ) GI* GREASE DUCT & CHIMNEY SPECIFICATIONS, PROVIDE GREASE DUCT EQUAL TO CAPTIVEAIRE SYSTEMS MODEL 'DW' ROUND 20 GAUGE 430 STAINLESS STEEL DUCTWORK. MODEL 'DW' IS LISTED TO UL -1978 AND IS INSTALLED USING 'V' CLAMP LOCKING CONNECTIONS SEALED WITH 3M FIRE BARRIER 2000 PLUS. MODEL 'DW' DOES NOT REQUIRE WELDING PROVIDING IT HAS BEEN INSTALLED PER THE MANUFACTURES INSTALLATION GUIDE. PROVIDE RATED ACCESS DOORS AT EVERY CHANGE IN DIRECTION AND EVERY 12' ON CENTER. PER MANUFACTURES LISTING MODEL 'DW' HORIZONTAL RUNS LESS THAN 75 FT. CAN BE SLOPED 1/16' PER 12', HORIZONTAL RUNS MORE THAN 75 FT. CAN BE SLOPED 3/16' PER 12'. DUCT SHOULD BE SLOPED AS MUCH AS POSSIBLE TO REDUCE THE CHANCE OF GREASE ACCUMULATION IN HORIZONTAL RUNS. IF THE DUCT OR CHIMNEY IS WITHIN 18 INCHES OF COMBUSTIBLE MATERIAL, PROVIDE UL -2221 OR UL -103 HT LISTED DOUBLE WALL GREASE DUCT OR DOUBLE WALL CHIMNEY EQUAL TO CAPTIVEAIRE SYSTEMS MODEL 'DW- 2R, 2R TYPE HT, 3R, OR 3Z' ROUND 20 GAUGE 430 STAINLESS INNER DUCT INSULATED WITH A 24 GAUGE 430 STAINLESS OUTER SHELL. CAPTIVEAIRE SYSTEMS RECOMMENDS THE USE OF LISTED, PRE -FABRICATED ROUND GREASE EXHAUST DUCT TO REDUCE STATIC PRESSURE IN THE SYSTEM, MINIMIZE INSTALLATION AND INSPECTION TIMES, AND ENSURE DUCT IS LIQUID TIGHT VERIFY CEILING HEIGHT HOCH( REPOSED ,o PEW.. n,,, HOOD FITS SPACE AND ,a S., ,HE ENCILOSIPLE PANELS HVAC DISTRIBUTION NOTE HIGH VELOCITY DIFFUSERSOR HVAC RETURNS SHOULD NOT BE PLACED WITHIN TEN (10) FEET OF THE EXHAUST HOOD. PERFORATED DIFFUSERS ARE RECOMMENDED. CUSTOMER APPROVAL TO MANUFACTURE: ..,..., a NEU 0 0 scmmn Qk0 Aii—.-a = ® ®W = 10BZarrllla LOCATION MERRITT ISLAND, FL, 32952 DATE 7/24/2018 ✓OB # 3485537 DIYC#1 REV DRAWN BYreg41 SCALE 3/8' = 1'-0' P2XHAUST FAN IIVF'U!(M4J!UIV — ✓00T7o•ra000r FllJV TAG !RP V!(Ml111V4Y - ✓ u u g u-tV.1.,..'r FAN UNIT MODEL R BLOWER HOUSING MIN CFM DESIGN CFM FANDISCHARGE RPM H.P. B.H.P. 0 VOLT FLA WEIGHT (LBS.) SONES 2 FLA 61-G10 WEIGHT SONES UNIT NO, TAG FAN UNIT MODEL N CFM ESP. RPM H.P. H.H.P. 0 VOLT 13.4 VELOCITY (LBS.) 1 0U851-1FA 1410 1.250 1307 0.750 0.4420 1 ' 115 8.8 446 FPM 97 14.6 MUA FAN UNIT NO. FllJV TAG !RP V!(Ml111V4Y - ✓ u u g u-tV.1.,..'r FAN UNIT MODEL R BLOWER HOUSING MIN CFM DESIGN CFM ESP. RPM H.P. B.H.P. 0 VOLT FLA WEIGHT (LBS.) SONES 2 Curb 61-G10 GIRD Al 0 1128 0.400 732 1.000 0.3110 1 115 10.2 212 13.4 1� 1'HIV FAN UNIT NO. VPT TAG N.J OPTION (Qty. - Desc,-.) 1 GREASE CUP 1 - Grease Box WALL MOUNT 1 - Miami Dade Certification. GRAVITY DAMPER 1 - Fan Base Ceramic Seal - Ship Loose - For Grease Ducts 1 - ECM Wiring Package -Exhaust - PNM Signal from ECPM03 Prewlre (NIDEC Motor) 2 Curb 1 - Miami Dade Certification. 2 1 - ECM Wiring Package -Supply - PWM Signal from ECPM03 Prewlre (NIDEC Motor) FAN UNIT NO. TAG EXHAUST SUPPLY GREASE CUP GRAVITY DAMPER WALL MOUNT SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER WALL MOUNT 1 Curb YES 2 N 2 48 LBS Curb 21.000'W x 29.000'L x 20.000'H 2.00042.000 Pitch Along Width. Right Insulated 16 Gauge UUljli 11;:i3 ,"MbL1,G'] N0.ON FAN HEIGHT ITEM SIZE 1 0 1 70 LBS Curb 23.000'W x 23.000'L x 26.000'H- 2.00042.000 Pitch Vented Hinged 16 Gouge 2 N 2 48 LBS Curb 21.000'W x 29.000'L x 20.000'H 2.00042.000 Pitch Along Width. Right Insulated 16 Gauge FAN #1 DUB5HFA - EXHAUST FAN GREASE DRAIN 22 1/2 DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) FEATURES, - DIRECT DRIVE CONSTRUCTION (N0 BELTS/PULLEYS) - ROOF MOUNTED FANS - RESTAURANT MODEL - 11L700 AND UL762 AND ULC -5645 - VARIABLE SPEED CONTROL - INTERNAL WIRING - WEATHERPROOF DISCONNECT - THERMAL OVERLOAD PROTECTION (SINGLE PHASE) - HIGH HEAT OPERATION 300'F ()49'C) - GREASE CLASSIFICATION TESTING . EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300'F (149'C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. ABN0RMAI FI ARE -UP TFST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600'F (316'C) FOR A PERIOD OF 10 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. J]PTTONS GREASE BOX. MIAMI DADE CERTIFICATION.. FAN BASE CERAMIC SEAL - SHIP LOOSE - FOR GREASE DUCTS. ECM WIRING PACKAGE -EXHAUST - PWM SIGNAL FROM ECPMG3 PREWIRE (NIDEC MOTOR). HIGH TEMP GASKET 1S USED TO SEAL THE FAN 111 THE TRANSITION PLATE, VENTED CURB ROOF TERMINATION. LISTED GREASE DUCT. 22 1/2 22 1/2 PITCHED CURBS ARE AVAILABLE FOR PITCHED ROOFS. VENTED CURB 16 GAUGE STEEL CONSTRUCTION ROOF OPENING DIMENSIONS SPECIFY PITCH. 12 EXAMPLE' 7/12 PITCH = 30' SLOPE EXHAUST FAN. THE INNER DUCT IS FULLY WELDED TO THE TRANSITION PLATE, ALL WELDS ARE DYE TESTED. SECURED TO THE CURB BY OTHER 0 1 CI Aff A AM-- - _ _ 11V v - JOB Zarrilla LOCATION MERRITT ISLAND, FL, 32952 DATE 7/24/2018 JOB # 3485537 BYO # 4 REV DR4!YN BYreg41 SCALE 3/8' = 1'-0' FAN 1!2 AI-G1OD - SUPPLY FAN 1. DIRECT DRIVE UNTEMPERED SUPPLY UNIT WITH 10' BLOWER IN SIZE N1 HOUSING WITH SPEED CONTROL, DISCONNECT SWITCH. 2. INTAKE HOOD WITH EZ FILTERS 3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT 4. MIAMI DADE IMPACT AND WIND LOAD CERTIFICATION - MIAMI DADE COUNTY PRODUCT CONTROL APPROVED. FLORIDA BUILDING CODE APPROVAL. EXHAUST CURBS UP TO 20' HIGH MUST BE 20 GAUGE ALUMINIZED. EXHAUST CURBS ABOVE 20' HIGH UP TO 42' HIGH MUST BE 16 GAUGE ALUMINIZED. EXHAUST RAILS LIMITED TO 10' HIGH. 5. ECM WIRING PACKAGE FOR SUPPLY MOTORS WITH PWM SIGNAL FROM ECPM03 PREWIRE. NOTE. SUPPLY DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS. A MINIMUM STRAIGHT DUCT LENGTH MUST BE MAINTAINED DOWNSTREAM OF UNIT DISCHARGE UNLESS OTHERWISE SPECIFIED. DO NOT RELY ON UNIT TO SUPPORT DUCT IN ANY WAY. FAILURE TO PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE EQUIPMENT. SUGGESTED STRAIGHT DUCT SIZE IS 14' x 14' x 48' LONG. LIFTING LUG 27 3/8' ---- 3 3/4' 20' EQUIPMENT CURB k___21' --, ROOF OPENING 2' SMALLER THAN CURB DIMENSION. 16 1/4' PITCHED CURBS ARE AVAILABLE FOR PITCHED ROOFS. SPECIFY PITCH. 12 EXAMPLE. 7/12 PITCH = 30' SLOPE BLOWER DISCHARGE 7 1/4' -I 13 1/4' 6 3/8' FLEX CONDUIT FOR FIELD WIRING 76 1/2' 32 1/8' 29 3/4' AIRFLOW �ISSERVICE DISCONNECT SWITCH BLOWER/MOTOR ACCESS DOOR 24' SERVICE 'C ACRR O. 48' MIN MUM STRAIGH DUCT 14' kited* O® JOB ZarrIlla LOCATION MERRITT ISLAND, FL, 32952 DATE 7/24/2018 JOB # 3485537 DWG # 5 DRAWN BYreg41 REV. SCALE 3/8' = 1'-0' MIAM WADE CQUUt TY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) SII DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.aov/economy CaptiveAire Systems, Inc. 4641 Paragon Park Road Raleigh, NC 27616 SCOPE: This NOA is being issued under the applicable rales and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER Product Control • Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the ABJ Cin areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AH7 may immediately revoke, modify, or suspend the use of such product or -material within their Jurisdiction. RER reserves the right to revoke-this_acceptance, if is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building cede. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hu>ricane Zone. DESCRIPTION: Span Aluminum Rooftop Fans APPROVAL DOCUMENT: Drawing No. EXHAUST, titled "Upblast/Downblast", sheets 1 through 6 of 6, dated 08/25/2008, with revision 1 dated 12/30/2008, prepared by CaptiveAire Systems, Inc, signed and sealed by L. David Rice, P.E., bearing the Miami -Dade County Product Control renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, one of the five manufacturing locations: Youngsville, NC or Muskogee, OK or Redding, CA or West Union, IA or Bedford, PA or Groveland, FL, model/series, and following statement "Miami Dade County Product Control Approved", unless otherwise noted herein. LIMITATIONS: 1) This approval is for anchorage into roof wood fraise members only with a minimum specific gravity (SG) of 0.42, 1-1/2" minimum edge distance and 2-5/8" minimum end distance. 2) These fans cannot be installed within the ridge area FSC 1523.6.5.2.13. RENEWAL ofthis NOA shall be considered atter a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur atter the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -bade County, Florida, and followed by the expiration date may be displayed in advertising literature.. If any portion of the NOA is displayed, then it anall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the -request of the Building OfficiaL This NOA 'renews -TOA # 13-0219.01 and consists of this page 1 and evidence page E-1, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. ,NOA No. 14-0110.04 Expiration Date: March 4, 2019 Approval Date: March 6, 2014 Cl T Y OF MELBOURNE BUILDING DEPT. Page 1 • al f ' REVIEWED FOR CODE COYPLIANCE EDGAST �•�,3�tS CaptiveAire Systems. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBM11`1EI) A. DRAWINGS "Submitted under NOA # 08-1124.09" 1. Drag No. EXHAUST, titled "Upblast/Downblast", sheets 1 through 6 of 6, dated 08/25/2008, with revision 1 dated 12/30/2008, prepared by CaptiveAire Systems, Inc, signed and sealed by L. David Rice, P.E. B. TESTS "Submitted under NOA # 08-1124.09" 1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per. FBC, TAS 203-94 along with mm-kPd-up drawings and installation diagram of Series/Model ERE-24,.higjh velocity roof fan, BI 36CARM, roof mounted exhaust fan and A5-925, modular down discharge blower, prepared by Architectural Testing, Inc., Test Report No. 83747.01-109-18, dated 10/15/2008, with Revision 1 dated 01/06/2009, signed and sealed by Michael D. Stremmel, P.E. C. CALCULATIONS 1. Anchor verification calculations, prepared by Rice Engineering, dated 07/04/2012, signed and sealed by L. David Rice, P.E. "Submitted under NOA # 08-1124.09" 2. Anchor verification calculations, prepared by Rice Engineering, dated 11/12/2008, with revision dated 01/20/2008, signed and sealed by L. David Rice, P.E. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. F, STATEMENTS "Submitted under NOA # 13-0219.01" 1. Statement letter of code conformance to 2010 FBC issued by Rice Engineering, dated 07/04/2012, signed and sealed by L. David Rice, P.E. 2. Statement letter of no financial interest issued by Rice Engineering, dated 07/04/2012, signed and sealed by L. David Rice, P:E. "Submitted under NOA # 08-1124.09" 3. Laboratory compliance letter issued by Architectural Testing, Inc., for Test Reports No. 83747.01-109-18, dated 10/16/2008, signed and sealed by Michael D. Stremmel, P.E. OA- oggirr Carlos M. Utrera, P:E. Product Control Examiner NOA No. 14-0110.04 Expiration Date: March 4, 2019 Approval Date: March 6, 2014 E -1 . • R uVislon History it PeNripilon Revlsed by Half! ' Dole • Materials A Series Steel Supply Fans- 0 Toiling TAS - 0L2,2032 N Fern/ 1446 0/28/08 - 1 Changes Por Dago County N 9 tarry 1446 12/30/08 2. HU Olm Changes N Perry 2181 . 11/19/10 3 -Added-RE PAO° N OA 2 11 ?airy 21/12 4/21/1.2 • , • 4 Added URI I Pon To h OA 2 N Petry 2490 10114113 (1) 8 e . Item Number Description Material 1 End Plashing 18 ea Galvanized 690 0 • 2 Main Roll 12 Ga titiNanIzed 690 • 1 goitom 18 Ga Galvanized 090 4 Bottom 51d 14 Ga 6 alvanIrCidd90 -44101,117. 5 Horizontal Support 10 Ga Galvanized 690 O. 0 . a Disallow Cap 18 Ga Golvonized (30e 7 • Door Hook Rack . 18 Ga Galvanized 1390 40101104"116W1 8 Door Hook•Front . '1130a Galvanized 090 il•P'''''''---;IPPlir- 9 Door cup 18 Ga Galvanized G90 luu h. • --- Ali 10 Right Front Po9L 18 Ga Golvanlied G90 • 11. tett Front Post 18 ila Galvanized G90 dc 12 11d 18•Ga Galvanized 690_ . . Y ••• 18 Drip gall Me Galvanized 090 ..,. ••• , • 44 .,• 14 DoorSupport 18 Ga Galvanized G90 • '''''.7';'..*4..., ...„.-4: , -. - 15 • Lld Support 14 Ga Galvanized G90 - .• •-. IL. , c4;• `7,.----.111010y, " , • ..- • (ID 16 Back . 18 Ga Galvanized G90 0 17 Door 18 Ga Galvanized 690 - 18 Back Door 18 Ga Galvanized 090 • 0 19 Blower Steel Awning Top •18.Ga Galvanized 690 • 21 21 ra20 Awr.1 ft htSide 18 Ga Galvanlzdd GDO 22 Awning left 51de 18 Ga Galvanized G90 pitoomr 011V131113 23 Awning Bottbm 18 Ga Galvanized G90 ot to0pIrIg widt the Mudd. 0 13.1141ag Gid. 24 Awning Middle la.aa Gikanlied a90 Aintreme No ',.., , 25 Awning Outside Rallr 18 Ga Galvanized 690 m4oi . k4. *. IlIMPAT .i, 26 Awning Italy Guard 18 GR GelvenIzed GO) 0) . Rail Sppbrts 18 Ga Galvanized 090 ri lo- . • 27 28 Awning zo A 25X 2 Filters. Aluminum Mesh Notes: 1. Tesied In ocoordtmce to Florida Building Code -I 2, Tesled lorareas Including high velciclly hurricane 3, let I ed.under Mlaml-Dade Counly NollfIcallon nuniber • • last protocol TAS -201, TAS -202, TA3203. zones, CaplIVeAlre, Inc. commercial kitchen NientliallOn ATI OB034. 4.041 Parcigon Park Road, RaleIgh..NO 27616. • P 000,334.026 1 F.0.10,227.5004 • . . . • - eirlot1 Ilitalgi A.r. NI u MANN !AIME P A .6. en IN ARA MN Millearigiarni121 MUM — or. — ""''''..."' Vaela ; _x 9 11 v i am, ut ' par c--:- i:.,: .. ,,: ,r,,,,..,i, ivradp.....--__.=:r... . 6 r. n a i: N Perry eelmal: • • ,105511MIF Tr="Ar === ' 6 i 1 wiper: NONA *ors ii THE PERPOPIMANCE COMPANY 00• 0 10 „ to' „ow N 044, f. NX: My,i, /Alt ONA 1.00 kti 9, 20 1% A RICE 15NG/AritffitINTY las School desk Ira! 0500100Q WI 8.1011. phone, pan.ses.tcqz rine orma.reer yiwyLilca•Ino.00m floddo Min Hai F01000505061 Cat1111c0le of 601hott10110n1 11P090 L. ocmd Aldo gdoltIrollon tice. 50P23 `- •" 1. arF y ev 5 an IMF— $. Do5crlppllan Revised by ECIi pale Installation - IA1.Series Steel Supply Fans Installation 0 TeslingTAS-181,202,103 NPerry" 1446 0/2s/06 T Changeb Per Dade County N Perry 1446 12/30/09 —RAWDhnChanged - N Perry ITO1— 11/1'x/10 3 Added RO Pan To NOA 2 N POI'S' 2162 4/27112 ` r mato all Fan TO NOA 2 N Perry 24V0 I0J14/1 • • PIWOUCr PAVF•9ln e�,„q,InWkhIM n.i" era°" n•••vrb• He,4.11.0 If, d 4 .cam-�*' froe007-1-7_.7 old, 1 1/2" TYP. 2-5/8" Noles: 1. Tes ed In accordance 2. les ed (or areas Including 3, Tes�ed under Mlaml-Dade .._..- "" . � _ �•�•.. • TYP. lo Florida Building high velocity Counly - `►�. '#'0"-- Code lest hurricane Nollllcallon number _.. _ zones. . (7) PER protocol TAS ATI 08034, r LAG SIDE -201, '_` BOLTS MINIMUM. TAS -202, MAX HEIGHT TAS203. 1. SECURE FAN MINIMUM OF ((16)) CURB STEEL ZINC PLATEb 20" PER•SIDE FORA OF FAN INTO TOP 2. SECURE CURB DRILLING 1/�4" LOCATION SHOWN USING A MINIMUM ENBEDMENT), BOLTS AND ZINC FOR 3/8" SCREW ROOF FRAMING LAG BOLTS' PER SCREW DOWN THROUGH FAH BASE INTO.CURB I" FLANGE. CURB FLANGE. Depth/Mire, BASE 1 /4-1,4 WITH TOTAL OF TO DIA PILOT ZINC PLATTED PLATED SIZE MEMBERS SIDE, TOP 4641 TO TOP OF CURB USING X 1" SELF DRILLING A MINIMUM OF OF (16), THROUGH CURB. ROOF FRAMING MEMBERS HOLES IN CURB IN BOTTOM LEFT DIAGRAM OF (28j 3/81' X 3" (MINIMUM STEEL LAG WASHERS THROUGH FLANGE WITH A MINIMUM INSIDE FAN BASE. Inc, colnmerolRl 141lolte11 Perngon Paric Road, Raleigh, P 000.334.026 IF 010,227.6094 A SCREWS, (A)) SCREWS BOTTOM BY AT AND ' AND INTO OF (7) O ventilation • NO 27616 . 2 11. Isopri. -' un,omroantl.J16.1: �E81. 11•••••=.1.B� r 1 161 m•of, � "~ A_ '6rlt t�► 13 b U , •` b�i.�o,,n� ad. m sr i 11., j' iii�p�r , ':L,,;; J "' ' ' 601,' • •65 Gad�mai � :.•; IdI ' L• . �1 wrolsc c 1: 1e. THE PERFORMANCE COMPANY 00;I a -e ste% fey 3`",.,4" t 80929 ,/NTA /l n F C • P ./ 42r �p'\ 7yoAG"'N' rrN11 may. 12, 2014 RICE ENGJNEBR11VG 105 Shcoal Reoktra6 tvxamburu, WI 61217 Plano: P20.046.1042 Fo" P20.815.1016 wvnk.11ca4no.com Floildo nen No: r-01000005061 CedIl cafe of Aulha4allor6 ADM L. Owed Rice RgOhlrallon No: 613F23 D mensianaN Data -. Upblast Aluminum Fans - NOA1. 1- T 1 General Notes: • evlon 10 R posoil Non Rovsedby ECNI dale. 0 TesI1nDTA0.201,202,203 14 Pony 1446 1448 13/213 10 I Changes Per Dade County N Pony 12/ O 00 01125 25-1/4 25-1/2 21 50 1. This approval Is for the structural capacity and Impact raling of the exterior housing only: t does not Include any Interior mechanisum or eteo steal part. 2. These tans have not be wind tested for Wind Driven Rain Teat per Florida Building code, TA3100 (A)-96. . FAN MODEL HT (1n) W (In) G (In) WEIGHT lDE) DU10 .14-1/2 17-3/4 19 30 01112 18 22 19 40 01125 25-1/4 25-1/2 21 50 DU30 25-1/4 25-1/2 21 50 DU33 25-1/4 25-1/2 21 50 01150 27-1/4 28-7/8 21. 55 DU75 30-1/2 31-7/8 24-3/4 60 DU85 30-1/2 31-7/8 24-3/4 60 NCA08 25-1/4 27-1/4 21 105 • NCA10 27-1/4 30-1/4 21 120 NCA14 30-1/2 33-3/4 24-3/4 140 NCA16 33-3/4 39-3/8 28 190 N CA18 33-3/4 ' 38-7/8 28 195 NCA24 37-1/2 433/8 33 270 NCA30 40 52-3/4 40 410 NCA36 45-9/16 63-7/16 44 470 I -DEfiIGN PRESSURE: +30.0 / —66.0 PSF W'' LARGE MISSILE IMPACT RESISTANT Nolest 1. Tested In accordance to Florida Building Code teat protocol TAS -201, TAS -202. TAS203, 2. Tes ed for areas Including high veloolly hurricane zones. 3, Tea ed under Miami -Dade County Nollfoallon number ATI 08033, EPfGJNRRRZPIO 100 BChool Dwolt Troll Ivmmbulp,Wt 1140.11 I have: 010.0401042 1 ax: 0?0.040.1040 . ', welsa no,00m Frew Pmt Not 1401000000001 Oadlllcol of Auibo111mion: 00000 4•DsvW two tt4gl.11olon140:110023 ' JAN 2 0 1?009 PRDIHICT IIHNIlWfle PRUDacr n8vis0o n onmph'I^a rhA uw.r1«le. N wmPlrrne wilt, rhe Flatda m.p w .1A st,o Atl1, moo !' 4 /0 0 b ihikwe 140 - i 1 ' ,1 t o. i ii? I • prylnllat /Y1i .0 OtpirM.rbn f - . F/011kd ¢ r R Oontrol r,�jpm 4.. • o VN (.alhgl rrr d_ ' 4rE1 s 1111111 q[J� Is;r1 %MI•• e. 1i : Ir.' 1 0. 1.:►1e1 ., .►Uure MAW 0l 9 Dldon elhwok11O aoIDod Drm.nUonr ole rn rnoho.. 6@Innanldml rwe.mm 401 :1 :, to Anulon 2 Ark inta ammoM1 mail► == if Fir THE PEBEUBMANCE COMPANY Exploded Material View - Upblast Aluminum Fans - NOA1. Item Number is sii ---..•b in .c, .00 12/00/00 0 2• 1 .___,____N . l Pal 0udwunry Chaneo N PoiiY 446 Item Number Description Material' . 1 Baso is Ga Galvonly] d 2• Dar Ile 060 AIumIIlum 1100-0 3 Gusset • 126a Galvanized 4 Vertical Support • 12 GoGolvenlzed 5 Bottom skirt • .090 Aluminum 1100.0 6 Wheel Blade Top (Not Shown) 14 Go Galvanized 7 Wheel Blade Bottom .100Aluminum 3003-0 8 Wheal Primary Blade .125Aluminum 5052-1132 9 Wheel Secondary Blade (Not Shown) .084 Aluminum 5052-H32 10 Top skirt A ' .080 Aluminum 11004114 11 Top Skirt B .080 Aluminum 1100-1114 12 Angle Ring 1/0 X 1K 1Aluminum Angle Ring 13 Hood .004 Aluminum 1100-1114 14 • Shaft Wrapper .080Alumlinum 1100.114 15 Ilorizonlol Braces .126Aluminum 5052-1132 16 cooling Tube .080AlulninumExtrusion 17 Cooling Tube Grolnmet Back Rubber 18 . Motor Plate Assembly . 10 Ga Galvanized 19Top Plate 14 Ga Galvanized 20 Shaft (Not Shown) • 1018 Steel . 21 Vibration Isolators Black (tubber 22 Fon Plate Left (Hinge Klt) 10 Ga Galvanized 23 • Curb Plate Left (Hinge Kit) iDGa Galvanized 24 Fen Plate Right Vilma Kit Not S11own). 10 Ga Galvanized - 26 curb Plate Right Mime Kit Not Showy) Curh • 10 Ga Galvrfhlzed Mee Alumldlzed 26 27 Grease Down Spout Dox Aluminum Col ritei)Vinyl 10. Ga Ga(vanlzed 28Grease Notes: 1. Tested In ciccordanoo lo Florida Dullding Code -lest prol000l TA3-201, TA9-202, TA5203. 2. Tested for areae Including high velocity hurricane zones. 3. Tesled under Mloml-bade County Nollllcallon number All 00033. ale f 1(7001110;i10e; ►1P x 'f 1 •a ocatplytnct vhh We F1,alde Building We Aoo.plence No Bxpl l so complying whh Ib r !o,l4 Duad108 00 Aocspla000 Na mWim, j .00 111,E 1 •. . 0ty 6z1(11Fr17 •I CI Conal Drawi bjuw Sbee Olandord of (gnaw 0101 Flat Amt 4 Deomalr. :Ale Analnx RICE ENGINEERING • 10084hooi Cleek TPDl1 LuzomburO;W1 01211 Mono: 020.040 1012 Fox: 020.040.1040 WYAV.11COMO.ttm Flo1kl Sun F411000508001 Ce111i1 OD of Aulholht4140: 00600 L-ODV I teve maid ollop No: 00023 JAN 2 0 2009 /MM$4 11Oa with it" ri:lf/Ll ery Chnehl THE PERFORMANCE COMPANY 2./7 Installation - Upblast Aluminum Fans. - fiOA1. MAX CURB HEIGI IT 20" CENTERED TYP, 3" TYP. 1 1/2" Notes: 1. Tested In aocordanoe to Florida Building Code test protocol TA9-201, TA9=202, TA9203. 2. Tooled for areas Including 1110 veloollyy hunlcano zones. 3. Tested under Miami -Dade Counly Nollfcallon number ATI 00033. Revision Nlolory Dwell Ilol] RovlsedpY 1CN11 Dale 0 T Tesling TA9 - 201, 202, 203 N Petly 1440 A/20/UA Changes Por Dade ootnly N Perry 1446 12/30/00 -1. SECURE LID TO FAN USING (8) 1/4"-14 X 1" ZINC PLATED STEEL SELF DRILLING SI-IEET METAL SCREWS WITH RUBBER WASHER SPACED EVENLY AROUND LID. 2. SECURE FAN BASE TO CURB USING A MINIMUM.PLATED STELOSELF (12DRII LING SCREWS THROUGH PRE -PUNCHED HOLES IN THE FAN BASE WITH A MAX SPACING OF 16" INCHES. 3. SECURE CURB TO ROOF FRAMING MEMBERS BY DRILLING 1/4" DIA PILOT HOLES IN THE CURB FLANGE AT LOCATIONS SHOWN IN THE DIAGRAM AND USING A MINIMUM OF (12) 3/8" X 2" (MINIMUM ENBEDMENT), ZINC PLATED STEEL LAG BOLTS AND ZINC PLATED WASHERS FOR 3/8" SCREW SIZE THROUGH FLANGE AND INTOROOF FRAMING SPACING OF MEMBERS 1/4WITH A 4 . MAXIMUM mower pMNIBWpp • rnoeucLr BnVlsin vr*,ylq whh 0.o Made nulldlrq (I whh the Florida ld, i ? 1,1cnoO No I nulldIns bed+ Acceptance EtapIrwbn ,N�Jx1RJFo ,talo c1 •Mot GINCtESRJNO WB aENhost Orook Tlnll Lvxombur ,WI 01111 plronot 900.0111042 Fen; 010.048.10411 vm+uke•Ino.uom el Ida Firm No; P•0I000008001 on snow 0lAulh ,lteoon:n9o00 1.. nevld NCO c olatellon No: 00013 AN 2 0 2009 • =lair 4L7eai1 _ " Pjfi Inion Olhend,v oc18o brnrornlonl uro11 noho,. t@Ionndau �gT�E, uror, oo4noh 3.010 Anoka : Aft DER Air ott—Eri THE PERFO.RMANCH COMPANY Fyre Trap® EZ 1.5 Duct Insulation — Sin` Ie -Layer. System IntrcducTJon Unifrax`s FyreWrape a 1.5 Duct Insulation is a new optimd single-layerf edoIe enclosure for 1- and 2 -hour fire -rated kitchen exhaust duct and chemical fume ducts. This slim, compact designoars the tightest system available and results in significant weight, space and labor savings when compared to trad`rdonal gypsum shaft walls or competitive wrap systems. FyreWrap E 15 provides the following features • Thinnest, lightest system available • Saves weight, space, labor • High-temperature, biosoluble insulation • 1- and 2 -hour fire endurance rating • Zero clearance to combustibles at the overlap or collar • Alternate to fire -rated shaft enclosure FyreWrap° Ej 1.5 Duct lnsulaiion Product Corriponerits _Corgi MateddaL• tWrap-EZ-1- 5-incorporates-4nsutira.° type cel--Ritadu.ct-Pa rarneters Thermal Insulation as its core material Insulfax is a high- temperaiure insulation made from. a calcia,• magnesia, silica chemistry designed to enhance biosolubiiitty. It provides excellent insulation in a noncombustible blanket product form. Encapsulating Material: The core insulation blanket is completely ensulated in an aluminum foil fiberglass reinforced scrim covering. This scrim provides additional handling strengtil as well as prctection from grease and moisture absorption and tearing. Typical Product Properties Thickness Density Standard Product Form Produce Avaiabiidy 6pcf Scrim Encapsulated 24°w x 25LF 48°w x 25LF Omega Point Laboratories (OPL) Listed ICC Evaluation Service (NES) UL 1978 Internal Crease DuctTest ASTM E-119 Full Scale Engulfment Test ASTM E-814Through-Penevation Rrestop Test ASTM E-84 Surface Buming Characteristics • Flame Spread Rating: Smols Developed Rating: ASTM E-136 Non-combusubiity Test ASTM C-518 Durability Test File 16210-4, Design Nos. GD 5o6 r GD 561 F, CFFDi 505 F L-egacy Report NER-509 Zero Clearance to Combustibles at Overlap or Collar 2 -hour Fire Endurance Raring F -;rating = 2 hrs.; T -Rating = 2 hrs Unlaced Blanket Encapsulated Zero Zero P -asses Passes c0 NE -1 -EMB Data are average results of tests conducted under standard procedures and are subject to variation. Results should not be used for specification purposes. - Compiles w@h : NFPA101, 96, 90A, 90E, 2003 Intern -atonal Mechanical Code (1MC), 2003 International Building Codes (IBC), 1997 Uniform Mechanical Code (UMC) and 1997 Uniform Building Code (UBC) Carnptim wfft= NFP se Duct Support Horizontal duct support systams ars not required to be insulated (wrapped when constructed using a minimum 0.5° diameter uninsulated ail -thread steel rod and 2° x.2° x 0.25' unirsui ad steal angle spaced a maximum 60° on center along the length of the duct. A minimum clearance of 2° is required between the protected duct and the steel rod. For ail other duct support configurations, a single layer of FyreWrap 15 Duct insulation is required on all components. Utilize a minimum 3° overlap (apprc dun iy a W tum) on all joints. Firestcp Systrs Refer to Figures 4 and 5 for details. Contact Unifrax Application Engineering Group at 716-279-3888 or visit www.uniirx.com for the latest information on available iirestop systems. FyreWrap® EZ 1.5 Duct Insulation Throw Penetration Firestop System DPL Design No. FS 589 F F-Rafina = 2 hours, T-RPtg = 2 hours Lasa 1 1 Concrete Roar Amonbip, 4h' dem 2 ' Crewe Drz3, 16 gauge, may. 50' z N' 3 FyreWap' EZ 15 Owl lnsutaHmr, One Layer 4 1 tinemi Wool (4 pd), compressed a-% or Unlaced FyraWrap' c_715 lftriket 5 I Tremco Fyre-Sill Non -Sag, W-35' depth, flush vial suifae:e of dab Figure 4. Duct lnsialIation Fyn:Wrap® 1.5 Duct Insolation -onah Penetration Fa -estop System OPL Desire No. FS 589 W R Q=thours, ''Raimo=2 hours 0 11111© ;illl�lf;i 111111 a ©`Till Lagenct 1 I Gypsum Wallboard Assembly, 2 hr. dial a &ease Duct. 16 canoe,mem 50' x 50' 3 FyreWrap' EZ 15 Duct Insulation, One Layer 4 isuneral Wool (4 pal, compressed or Urrc:d F rreW rap' U 1.5 Wankel 5 Tram= Fyre-S111 Non -Sag, 'A' -r2 depth, both sides of -wall and ovedenped iz' or Mrd and wall surfaces Figure 5. Duct lnstaflatian Refer to the product Material Safety Dad Sheet (MSDS) for recommended work practices and other product safety inforrnafon. For additional information about product performance or to identify the reontmended productior your fire protection applicafion, please contact the Uni(rax Appiicafion Engineering Group of 716-Z7B-3888. Pof APPLIED FIRE PROTECTION o 'h =TUX COSPOMATION Amherst, NY ICBO RS R.-5399 Okay.„, Prod et ID 016201-4 Laz"ted Omega Fad t Laboratories WEB QA. 7 & icao ALIM77 le iron_._ ,a,�,. ariiar3 jr...T.-...eF},ri....ir4 {_ r n4="Erz ] F RAP® Aapfl &,ns pe: r3se=tary Foran 0 1439 aieetve 304 e 21763. 2604 Untraz Corporation AA Fffghts Resent/ 'Printed in USA Page 5a6 Vertical Duct Runs For vertical duct runs, insulation may be applied to the duct in a continuous length parallel to the vertical length of the duct as opposed to wrapping around the duct. All overlaps shall be maintained at a minimum 3° and are to occur a minimum 6' from any comer of the duot_ Pins spaced a maximum 5° on center are to be placed at the centerline of all vertically oriented overlaps. See Figure 2 for detafs. LL- FyreWrap® EZ 13 Duct Insulation Insulation Technique —Vertical Duct kms Nu i t:: Omega Point Laboratories Design GD 550 F Figure 2. Optional installation Technique — Vertical Duct Suns Attachment Options Three attachment options are available for installers. Choices are limited by the duct width dimension. Details on each. option are provided below. Banding Onty: For Duct Widths 24° or Less, To temporarily secure the insulation, optional use of filament tape is permitted. Place stainless steel bands (min.'s' wide, nom. O.D15° thiciover joints and within the field around the wrap. Locate bands 11 from•each edge of each blanket overlap. Place a minimum of two additional bands in the field area between the overlaps on maximum 8 centers. Tighten banding to firmly hold the wrap system in place but not so tight as to cut or damage the blanket Pins are NOT required when this banding technique is used. Banding and Pins: For Duct Widths Lip to 24° x 48° Weld 12 -gauge steel insulation pins to the underside of hortzor itd1 runs and backside of vertical runs. Place pins at maximum 12° rows and on maximum 11714 centers. To temporarily secure the.insulafion, optional use of filament tape is permitted. Impale FyreWrap EZ 1.5 over the pins and hold in place with 2'r'° square galvanized steel speed clips (washers). Tum down or cut off exposed ends of pins to eliminate safety hazards. Locate stainless steel bands (min. ° wide, nom. 0.015° thick) 1X° from each edge of an overlap joint Locate a second band midpoint between the over- lapped joints, approximately 10° on center. Tighten banding to firmly hold the wrap system in place but not so fight as to cut or damage the blanket Pins Only: For Any Duct Width Weld 12 -gauge steel insulation pins on all sides of the duct Place insulation pins in rows (perpendicular to the length of the duct) spaced maximum 10'/° on center, Pins in each row are maximum 5' from each duct edge and maximum 8' on center. Locate insulation overlaps so they are centered on the pins. Impale FyreWrap F113 over the -pins and hold in place with 2'1 square galvanized steel speed fps (washers) to keep the system from sagging. Tum down or cut off exposed ends of pins to eliminate safety hazards. Farm C -14J Marin a% ® 21303.2054 Unify Corpnmfinn AD Fights Reserved Pruned in USA Page 3of6