Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Permit Application: Permit # 16-0283
Dates of Record Dates of Record Item No. Record Series Title From: To: No. of Pages 21 Building Permit Application: Permit # 12741 2015 2017 12 22 Building Permit Application: Permit # 12518 2015 20 23 . Building Permit Application: Permit # 16-0038 2016 40 24 . 'Building''Permit"Application:,Permit # 16-0283 ,0,,q, ,,-, . - A e 2016: 56,, 25 Building Permit Application: Permit # 16-0285 2016 . 44 26 Building permit Application: Permit # 16-0517 2016 12 27 Building Permit Application: Permit # 15-19290 2015 28 28 Building Permit Application: Permit # 16-0769 2016 8 29 Building Permit Application: Permit # 16-0679 2016 8 30 Building Permit Application: Permit # 16-0691 2016 10 31 Notice of Commencement: Permit # 16-0741 2016 3 32 Building Permit Application: Permit # 17-0835 2017 59 33 Building Permit Application: Permit # 17-0992 2017 35 34 Building Permit # 17-0677 2017 26 35 Building Permit Application: Permit # 17-1170 2017 14 36 Building Permit Application: Permit # 17-1239 2017 16 37 Notice of Commencement: Permit # 17-1533 2017 21 38 Building Permit Application: Permit # 17-1357 2017 14 39 Building Permit Application: Permit # 17-1343 2017 20 40 Building Permit Application: Permit # 17-1404 2017 10 41 Building Permit Application: Permit # 17-1403 2017 , 8 42 Building Permit Application: Permit # 17-1436 2017 9 2111 Date: ::>)iIi (0 CITY OF CAPE CANAVERAL Tracking # RECEIVED BUILDING PERMIT APPLICATION i" Permit # 14� O a 3 MAR 21 2016 (321)868-1222 City of Cape Canaveral Building Department - P.O Box 326 - 110 Polk Avenue - Cape Canaveral, FL 32920 You may download this application: www.citvofcaTecanaveral.ora. You may fax to: (321)868-1247. All applications must include the backside of this form and 2 sets of supporting docuthents. Important: Please complete the checklist on the back of this form and provide other documentation as indicated on the checklist. A copy of contract may be required. Application packages will not be accepted unless complete. APPLICANT WILL BE CALLED WHEN PERMIT IS READY (Contractor/Owner-Builder is required to sign for the building permit. unless indicated otherwise by affidavit. l.D.'may b Address of Job Site: \4\ Ce.'(\ Zoning classification: Legal description of property: TWN: RNG: SEC: SUBD: BLK: LOT: Property Owner Name: T\ 1 l S 'Address: COLi ' ..ctm t AiN Joi-}5g e required) Flood Zone: PB: PG: rt LLB Phone: 4 atl -Loa -Licvss ,Fee Simple Titleholder's Name (if other than owner) Address: ,Bonding Company: Address: Mortgage Lender: Address: ' Type of Permit Brief description of work: Building Electrical Plumbing Mechanical ,/Other AMA '`CAU(D- r'Ar. slorva& ( vracks qBuilding Type of (please indicate as a�licable) Square Feet under roof Const. Type (IA, VB, etc) Occu- pancy Classifica -tion (B,RI.R3 etc.) FPL lines currently available to serve this property? Yes/No City Sewer available to serve this property? Yes/No # of Concrete! Asphalt Parking Spaces # of stories # of dwel- ling units #'of bed- rooms 1/ of water closets ! Valuation of work (Copy (it -Contract Required) 'commercial $ COI 760, 06 SFR - $ Townhouse $ Apartment • $ Condominium $ Other $ Architect/Engineer Name: Name of Company:. Address: - State License No.: Phone (office): Phone (cell/pager.): i Fax: , Primary Contractor Name: & r a,. ' \•., - , .f, is Name of Compan : rem. R ,a it _ f IN.., Address: . ► ` i 'i" `E[ _.t t • I 1 State License No.: 35-f(p.b ji-IWPhone (office): , -g-7 Phone (cell/pager.): Fax: I/07-6X-94-1/0, Electrical Contractor Name: Name of Company: Address: State License No.: Phone (office): Phone (cell/pager.): Fax: Plumbing Contractor Name: Name of Company: . Address: State License No.: Phone (office): Phone (cell/pager.): Fax: Mechanical Contractor Name:. Name of Company: -Address: ' State License No.: Phone (office): Phone (cell/pager.): ; Fax: Specialty/Other Contractor Name: Name of Company: .Address: .State License No.: Phone (office): Phone (cell/pager.): . Fax: J Building Permit Application Checklist Notes . Completed Permit Application Current code edition: FL Bldg. Code Fifth Edition (2014) Current survey showing all proposed construction and landscaping Check with Bldg. Dept. for setbacks Notarized signature — Owner/Builder Affidavit If owner is acting as contractor Sewer Impact Fee receipt May be deferred until C.O. Unless job is remodeling County Impact Fee receipt May be deferred until C.O. Capital Expansion impact Fee receipt Maybe deferred until C.O. Sidewalk Impact Fee receipt If sidewalk exists on lot Recorded Warranty Deed / Proof of Ownership Copy of Recorded Notice of Commencement (over $2,500) Over $7,500 for Mechanical change out Current Cert. Of Liability Ins./Worker's Comp. Policy / Exemption . Record will be kept on file after initial submittal Community Appearance Board Approval For all work visible from Public Right -Of -Way Planning and Zoning Board Site Plan Approval For all new construction of four units or more Concurrency Forms i For all new construction not part of approved site plan Primary Contractor's State License Record will be kept on file after initial submittal Subcontractor's State License Authorizations: Record will be kept on file after initial submittal Notify Building Department of contractor changes Plumbing Contractor Plumbing Contractor ' Electrical Contractor Electrical Contractor Mechanical Contractor Mechanical Contractor Roofing Contractor - Roofing Contractor Swimming Pool Contractor Swimming Pool Contractor 'Gas'Contractor Gas Contractor Specialty/Other Contractor 'Specialty/Other Contractor Construction Drawings: Per F.B.C. 104 Three sets of sealed construction drawings . Per F.B.C. 104 Truss layout and reaction summary Cut sheets and shop drawings will be needed at time of inspection Electrical Load Calculations Plans must indicate person responsible for calculations ,, _ Electrical Riser All new service must be located underground Plumbing Riser Plans must indicate person responsible for design r A/C layout Plans must indicate person responsible for design Two sets of Energy Calculations Plans must indicate person responsible for calculations Lot Drainage Survey , Four sets of Fire Suppression/Sprinkler/Alarm specifications Requires Fire Dept. approval prior to issuance of permit Pool Barrier Requirement Form (signed) Pool permits will not be issued without barrier Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to -meet the standards of all laws regulating construction in this jurisdiction. The Building Code in effect at the time of this application is the Florida Building'Code 5th Edition. I understand that all permits require inspections as indicated and that it is the responsibility of the permit holder to notify the building department when ready for inspection(s): This permit application is valid for 180 days from date of submission. By signing, applicant -affirms that all above is true and correct and that he/she is an authorized agent of the Contractor/Owner and has the authority to apply for this permit. *ALL OTHER APPLICABLE STATE OR FEDERAL PERMITS MUST BE OBTAINED PRIG TO COMMENCEMENT* Applicant's Name: lk#e( /1'Y1 Applicant's Signature: )J I I cer)kr Date: 3 (Q �(p Site Address:.:.. For Notary, use only: State of Florida, County of Brevard Sworn and subscribed before me this /(' day of it/tlire4, who roduced identification: or „_as„personalty known to me. 1 JACLYN CYR Notary Public - State of Florida My Comm. Expires Oct 1, 2016 Commission # EE 839507 , 20 ., by /%a`-4-`Y /76' ft- Printed name of Applicant Signature'Notary Public At Large This form may be duplicated. Dater'_ )ke I! CITY OF CAPE CANAVERAL Tracking # tC 1 a5147 RECEIVED - BUILDING PERMIT APPLICATION Permit # I Q- v 2 3 MAR 21 2016 (321)868-1222 City of Cape Canaveral Building Department - P.O Box 326 - 110 Polk Avenue - Cape Canaveral, FL 32920 You may download this application: www.citvofcapecanaverai.ora. You may fax to: (321)868-1247. All applications must include the backside of this form and 2 se of supporting documents. Important: Please complete the checklist on the back of this form and provide other documentation as ird d on the checklist. A copy of contract may be required. Application packages will not be accepted unless complete. APPLICANT WILL BE CALLED WHEN PERMIT IS READY (Contra/Owner-Builder is required to sign for the building permit. unless indicated otherwise by affidavit. I.D. may be required) Address of Job Site: 1"t. B\ C_e Pam ,- Zoning classification: Flo.dlone: Legal description of property: TWN: RNG: SEC: SUBD: BLK: L PB: : Property Owner Name: 1 / LL Pho' -: s , --L{ -` - S Address: CO-G 5 1$area - ctrN 1 AN /(y-f SC Fee Simple Titleholder's Name (if other than owner): Bonding Company: Address: Mortgage Lender: Address: Address: 4 Type of Permit Brief description of work: 5,-/p p IP Building 15 J Electrical g i& g 4 Plumbing WA t �j Mechanical ,/Other �.• '1^e-[ X.C�- �x� sprtawQ( vrp��.s 1 ) .' , _ tit .NI Type of Building (please indicate as le Iicable) Square Feet under roof Const. Type (IA, VB, etc) Occu- pancy Classifica -tion (B,Rl,R3 etc.) etc.) FPI, lines currently available to serve this property? Yes/No City Sewer available to serve this pro rty? Y. o # oncrete/ Asphalt Parking Spaces # ofof stories dwel- 'ng u 'ts # of bed- rooms # wa clos Valation (Copy of wor of Contract Req red) `co `commercial $ coo •Apartment SFR ` Townhouse p igrIP $ �� $ Condominium O� ,e $ Other 4 „ler S Architect/Engineer Name: Name of Company: Address: - `State License No.: -. Phone (office): Phone (cell/pager.): Fax: Primary Contractor Name: s ri i ' If ' r .i 4 Name of Company: ildi)1 : , y\ —, Address: . ► A _ a Vi nde ,: _rii'l �. 7 State License No.: 39-1- o- l-jQ Phone (office): . _-g I. Phone (cell/pager.): Fax: 1J07456"-9i-!05 Electrical Contractor Name: Nam- om.any: 'Address: 'State License No.: Phone (office): Phone (cell/pager.). Fax: Plumbing Contractor Name: Name of Company: Address: State License No.: Phone (office): Phone (cell/pager.): Fax: 'Mechanical Contractor Name: Name of Company: Address: 'State License No.: Phone (office): Phone (cell/pager.): Fax: Specialty/Other Contractor Name: Name of Company: Address: State License No.: Phone (office): Phone (cell/pager.): Fax: EAGLE FIRE PROTECTION, INC 1205 CROWN PARK CIRCLE WINTER GARDEN, FLORIDA POWER OF ATTORNEY PHONE: 407-656-8387 34787 FAX: 407-656-9405 KNOW ALL MEN BY THESE PRESENTS THAT MYRON B. HEATH, JR. HAS MADE, CONSTITUTED AN�4 APPOINT ND BY THESE PRESENTS DO MAKE, CONSTITUTE AND APPOINT Heatiorx ktil TRUE AND LAWFUL ATTORNEY FOR MYRON B. HEATH, JR. AND IN HIS NAME, PLACE AND STEAD FOR THE PURPOSE OF: Pt in ec.. GIVING AND GRANTING UNTO SAID ATTORNEY HAS FULL POWER AND AUTHORITY TO DO AND PERFORM ALL AND EVERY ACT AND THING WHATSOEVER REQUISITE AND NECESSARY TO' BE DONE IN AND ABOUT THE PREMISES AS FULLY, TO ALL INTENTS AND PURPOSES, AS HE MIGHT OR COULD DO IF PERSONALLY PRESENT, WITH FULL POWER OF SUBSTITUTION AND REVOCATION, HEREBY RATIFYING AND CONFIRMING ALL THAT AS SAID ATTORNEY SHALL LAWFULLY DO OR CAUSE TO BE DONE BY VIRTUE HEREOF. IN WITNESS WHEREOF, MYRON B. HEATH, JR. HAVE HERE UNTO SET HIS HAND AND SEAL THIS DAY OF , 20 MYRON B. HEATH, JR. MYRON B. NALLY KNOWN TO ME AND DID NOT TAKE AN OATH. __ STATE OF FLORIDA COUNTY OF ORANGE NOTARY PUBLIC ;J4h 4" COMMISSION NUMBER -FF. r393D1 COMMISSION EXPIRATION DATE - /WA 3>° DATE JACLYN CYR Notary Public - State of Florida My Comm. Expires Oct 1, 2016 Commission �'"" EE 839507 MAY/03/2016/TUE 08:33 AM FAX No, P. 001/001 1,,,,�� ..EAGLE.FIRE PROTECTION, INC. PHONE: 4o76568387• FAX:.407-B56=94t35 1205 CROWN. PARK CIRCLE • WINTER GARDEN, FLORIDA 34787 WWW.EAGLEFIREPROTECTIONINC.COM • • POWER, OF ATTORNEY KNOW ALL MEN 'BY'THESE••PRESENTS THAT.: MYRON.B. HEATH, JR.••HAS MADE, 'CONSTITUTED' AND'APPOINTED .AND BY THESE PRESENTS DO MAKE, 'CONSTITUTE • AND APPOINT '• ,Daar-N • TRUE AND LAWFUL 'ATTORNEY • FOR'MYRON B. HEATH, JR: AND IN HIS•NAME,.PLACE AND STEAD FOR THE PURPOSE' •' ' OF: • GIVING AND .GRANTING UNTO • . &04\ F r i n • SAID• ATTORNEY HAS' • FULL POWER AND•AUTHORITY TO DO AND •PERFORM ALL AND EVERY.ACT.AND'THING ' WHATSOEVER REQUISITE AND NECESSARY TO BE•DONE IN AND ABOUT. THE • PREMISES ;AS .FULLY;' • TO*.ALL INTENTS • AND PURPOSES, AS HE MIGHT. OR COULD DO.;IF PERSONALLY PRESENT; .WITH • FULL POWER' OP SUBSTITUTION' AND. ,REVOCATION,• .. . HEREBY RATIFYING AND CONFIRMING 'ALL THAT•AS. SAID.'ATTO'RNEY SHALL LAWFULLY DO OR CAUSE TO BE DONE BY'VIRTUE HEREOF. • • ERE UNTO SET HIS HAND AND.SEAL'THIS. DAY OF T\• , 20� j . MYRO� B. HEATH, JRi IS PERSONALLY KNOWN TO ME AND DID NOT TAKE AN OATH.. • STATE OF FLORIDA COUNTY OF ORAN NOTARY PUBLIC :-' • COMMISSION NUMBER' COMMISSION EXPIRATI.ONDATE - DATE • • JACLYN CYR . Notary.P•ublia • State ot•Florida • My Comm: Expires Oct 1, 2016 Commission # EE 839507 1' tIJCO Fire Suppression & Building Products o ucts Technical Services 800-381-9312 +1-401-781-8220 www.tyco-fire.com Series TY-FRB — 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb -type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following, • A two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a • A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. IMPORTANT Always refer to Technical Data Sheet TFP700 for the `INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Corrosion -resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion -resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TY- FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech- nical Data Sheet TFP780. NOTICE The Series TY-FRB Concealed Pendent Model/Sprinkler Sprinklersstlled described hcompliance must is bce Identification installed and maintained in com liance �+ this document and withthe appli- cable ember �SI N) standards of the National Fire Protection Association, in addition to the standards of any authorities having TY1131: Upright 2.8K, 1/2" NPT jurisdiction. Failure to do so may impair TY1231: Pendent 2.8K, 1/2" NPT the performance of these devices. TY2131: Upright 4.2K,1/2" NPT Owners are responsible for maintaining TY2231: Pendent 4.2K, 1/2" NPT their fire protection system and devices TY3131: Upright 5.6K,1/2"NPT in proper operating condition. The TY3231: Pendent 5.6K, 1/2"NPT installing contractor or sprinkler manuTY4131: Upright 8.0K, 3/4" NPT facturer should be contacted with any TY4231: Pendent 8.0K, 3/4" NPT questions. TY4831: Upright* 8.0K, 1/2" NPT TY4931: Pendent* 8.0K, 1/2" NPT 'Eastern Hemisphere Sales Only Ad00 33I*4( Page 1 of 10 JULY 2010 TFP171 TFP171 Page 2 of 10 6* 5 4 2 3 SSU * DEFLECTOR 7/16" (11,1 mm) NOMINAL MAKE -IN 2-3/16" 55,6 mm) CROSS SECTION 1 - Frame 2 - Button 3 - Sealing Assembly 1/2" NPT UPRIGHT 7/16" (11,1 mm) NOMINAL MAKE -IN WRENCH FLATS 4 - Bulb 5 - Compression Screw 1/2" NPT ESCUTCHEON PLATE SEATING SURFACE 2-1/4" (57,2 mm) 1-9/16" (39,7 mm) SSP DEFLECTOR* PENDENT 6 - Deflector 7 - Bushing STYLE 10 or 20 RECESSED ESCUTCHEON 2 7/8"(73,0 mm) DIA. —y RECESSED PENDENT Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT * SSU * DEFLECTOR 7/16" (11,1 mm) NOMINAL MAKE -IN 2-3/16" (55,6 mm) CROSS SECTION 1 - Frame 2 - Button 3 - Sealing Assembly 7/16" (11,1 mm) NOMINAL MAKE -IN WRENCH FLATS 1/2" NPT UPRIGHT 4 - Bulb 5 - Compression Screw 1/2" NPT ESCUTCHEON PLATE SEATING SURFACE 2-3/16" (55,6 mm) 1-1/2" (38,1 mm) SSP DEFLECTOR* PENDENT 6 - Deflector STYLE 10 or 20 RECESSED ESCUTCHEON 2 7/8" (73,0 mm) DIA. RECESSED PENDENT Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT TFP 171 Page 3 of 10 SSU * DEFLECTOR 7/16" (11,1 mm) NOMINAL MAKE -IN 2-3/16" (55,6 mm) CROSS SECTION 1 - Frame 2 - Button 3 - Sealing Assembly 7/16"(11,1 mm) NOMINAL MAKE -IN WRENCH FLATS 1/2" NPT UPRIGHT 4 - Bulb 5 - Compression Screw 1/2" NPT ESCUTCHEON PLATE SEATING SURFACE ---r 2-3/16" I(55,6 mm) 1-1/2" (38,1 mm) SSP DEFLECTOR* PENDENT 6 - Deflector STYLE 10 or 20 RECESSED ESCUTCHEON 2 7/8"(73,0 mm) DIA. RECESSED PENDENT Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT SSU * DEFLECTOR 1/2" (12,7 mm) NOMINAL MAKE -IN 2-1/4" (57,2 mm) CROSS SECTION 1 - Frame 2 - Button 3 - Sealing Assembly 3/4" NPT UPRIGHT 1/2" (12,7 mm) NOMINAL MAKE -IN 4 - Bulb 5 - Compression Screw 3/4" NPT ESCUTCHEON PLATE SEATING SURFACE f 2-5/16" 1 (58,7 mm) 1-9/16" (39,7 mm) SSP DEFLECTOR* PENDENT 6 - Deflector STYLE 30 or 40 RECESSED ESCUTCHEON 2 7/8"(73,0 mm) DIA. RECESSED PENDENT • Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT TFP171 Page 4 of 10 1 - Frame 2 - Button CROSS SECTION 3 - Sealing Assembly SSU * DEFLECTOR 7/16" (11,1 mm) NOMINAL MAKE -IN 2-3/16" (55,6 mm) 4 - Bulb 5 - Compression Screw 7/16" (11,1 mm) NOMINAL MAKE -IN WRENCH FLATS SSP * 1/2" NPT DEFLECTOR UPRIGHT 6 - Deflector 1/2" NPT 2- /4" I(57,2 mm) 1-9/16" (39,7 mm) PENDENT Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion -resistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K=2.8 GPM/psit'2 (40,3 LPM/barti2) K=4.2 GPM/psit12 (60,5 LPM/barti2) K=5.6 GPM/psiti2 (80,6 LPM/bart'2) K=8.0 GPM/psi112 (115,2 LPM/bartl2) Temperature Rating Refer to Table A and B. Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame Bronze Button Brass/Copper Sealing Assembly Beryllium Nickel w/Teflont Bulb Glass Compression Screw. Bronze Deflector Copper/Bronze Bushing (K=2.8) Bronze t Registered Trademark of Dupont Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB Pendent and Upright Sprinklers are intended for fire protection systems designed in accordance with the standard installa- tion rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Preven- tion Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB Sprinklers must be installed in accordance with the following instructions. NOTICE Do not install any bulb -type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C and 3/32 inch (2,4 mm) for the 286°F/141°C temperature ratings. Obtain a leak -tight 1/2 inch NPT sprin- kler joint by applying a minimum to maximum torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with con- sequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over -tightening the sprinkler. Re -adjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Upright Sprinklers must be installed in accordance with the following instructions. 1. Install Pendent sprinklers in the pendent position. Install upright sprinklers in the upright position. 2. With pipe -thread sealant applied to the pipe threads, hand -tighten the sprinkler into the sprinkler fitting. 3. Tighten the sprinkler into the sprin- kler fitting using only the W-Type 6 Sprinkler Wrench (Figure 14). With reference to Figures 1 through 5, apply the W-Type 6 Sprinkler Wrench to the sprinkler wrench flats. TFP171 Page 5 of 10 SPRINKLER FINISH (See Note 5) K BULB LIQUID NATURAL CHROME WHITE*** FACTOR TYPE TEMPERATURE COLOR BRASS PLATED POLYESTER 135'F/57°C Orange PENDENT (TY1231) 155°F/68°C Red 175°F/79°C Yellow and 1, 2, 3, 4 UPRIGHT (TY1131) 200°F/93°C Green 286FI141°C Blue 135F/57°C Orange 2.8 1/2" NPT RECESSED PENDENT 155°F/68°C Red (TY1231)* Figure 6 175°F/79°C Yellow 200°F/93°C Green 1,2,4 135°F/57°C Orange RECESSED PENDENT 155°F/68°C Red (TY1231)** Figure 7 175°F/79°C Yellow 200°F/93°C Green 135°F/57°C Orange PENDENT (TY2231) 155°F/68°C Red 175F/79°C Yellow and UPRIGHT (TY2131) 200°F/93°C Green 286°F/141°C Blue 135F/57°C Orange 4.2 1/2" NPT RECESSED PENDENT 155'F/68°C Red 1, 2 (TY2231)* Figure 8 175°F/79°C Yellow 200°F/93°C Green 135'F/57°C Orange RECESSED PENDENT 155°F/68°C Red (TY2231)** Figure 9 175F/79°C Yellow 200°F/93°C Green NOTES: 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion -Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. " Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. "` Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFP171 Page 6 of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME PLATED WHITE*** POLYESTER LEAD COATED 5.6 1/2" NPT PENDENT (TY3231) and UPRIGHT (TY3131) • 135°F/57°C Orange 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 5 155°F/68°C Red 175F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY3231)* Figure 10 135°F/57°C Orange 1, 2, 4, 5 N/A 155F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY3231)** Figure 11 135F/57°C Orange 1, 2, 3, 4, 5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 8.0 3/4" NPT PENDENT (TY4231) and UPRIGHT (TY4131) 135°F/57°C Orange 1, 2, 3, 4, 5, 6, 7 1, 2, 5 155F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY4231)* Figure 12 135°F/57°C Orange 1, 2, 5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY4231)** Figure 13 135°F/57°C Orange 1, 2, 3, 5 N/A 155F/68°C Red 175°F/79°C Yellow 200F/93°C Green 286°F/141°C Blue 8 0 1/2" NPT . PENDENT (TY4931) and UPRIGHT (TY4831) 135F/57°C Orange 1, 2, 4, 5, 6 1, 2, 5 155F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue NOTES: 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. 4. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead -Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion -Resistant Sprinklers. Where Lead -Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion -Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. *'- Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 7 of 10 SPRINKLER FINISH K FACTOR TYPE NATURAL BRASS CHROME PLATED WHITE POLYESTER LEAD COATED 2.8 1/2" NPT PENDENT (TY1231) and UPRIGHT (TY1131) 75 PSI (12,1 BAR) N/A RECESSED PENDENT (TY1231) 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (TY2131) 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY2231) 5.6 1/2" NPT PENDENT (TY3231) and UPRIGHT (TY3131) 250 PSI (17,2 BAR) OR 175 PSI (12,1 BAR) (SEE NOTE 1) 175 PSI (12,1 BAR) - RECESSED PENDENT (TY3231) N/A 8.0 3/4" NPT PENDENT (TY4231) and UPRIGHT (TY4131) 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) RECESSED PENDENT (TY4231) N/A 8.0 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 175 PSI (12,1 BAR) 5 PSI (121 BAR) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. TABLE C MAXIMUM WORKING PRESSURE The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. 1. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe -thread sealant applied to the pipe threads, hand -tighten the sprinkler into the sprinkler fitting. 2. Tighten the sprinkler into the sprin- kler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Fig- ure 15). With reference to Figures 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. 3. After ceiling installation and finish- ing, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB must be maintained and serviced in accordance with the following instructions. NOTICE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Exercise care to avoid damage to sprinklers before, during, and after installation. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Replace sprinklers that: • were modified or over -heated. • were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. • are leaking or exhibiting visible signs of corrosion. • were exposed to corrosive products of combustion but have not oper- ated, if you cannot easily remove combustion by-products with a cloth. • have a cracked bulb or have lost liq- uid from the bulb. Refer to the Instal- lation section in this data sheet. TFP171 Page 8 of 10 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) SERIES TY-FRB 3/4" (19,1 mm) 1/4"(6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) 1 1-5/16" (33,3 mm) 13/16"(20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) MOUNTING SURFACE CLOSURE 3/4" (19,1 mm) 1/4"(6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) 111 SERIES TY-FRB 1-1/4" (31,8 mm) 3/4" (19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Initial and frequent visual inspections of random samples are recommended for corrosion -resistant sprinklers to verify the integrity of the corrosion -resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. Inspections of corrosion -resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion -resistant material, which can be affected by the corrosive conditions present. 1 /2±1 /8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) -y SERIES TY-FRB 1/2" (12,7 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) 1-5/16" (33,3 mm) 1-1/16" (27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT _ 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) iIJ frA Mel W' / SERIES TY-FRB 1/2" (12,7 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) II 1-1/4" (31,8 mm) 1" (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Responsibility lies with the owner for the inspection, testing, and mainte- nance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdic- tion. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- . aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Initial and frequent visual inspections of random samples are recommended for corrosion -resistant sprinklers to verify the integrity of the corrosion -resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) MOUNTING SURFACE CLOSURE '‚p SERIES TY-FRB 3/4" (19,1 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) _=J 1-1/4"(31,8 mm) 3/4" (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) MOUNTING SURFACE CLOSURE SERIES TY-FRB rID rir .J► '. 3/4" (19,1 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) 1-5/16" (33,3 mm) 13/16" (20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Inspections of corrosion -resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion -resistant material, which can be affected by the corrosive conditions present. TFP171 Page 9 of 10 _ 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) SERIES TY-FRB 1/2" (12,7 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) 1-1/4" (31,8 mm) 1" (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE SERIES TY-FRB 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) 1/2" (12,7 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) 1-5/16" (33,3 mm) 1-1/16" (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS t PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH TFP171 Page 10 of 10 P/N 57 - XXX - X - XXX � l MODEUSIN 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2"NPT) TY2231 370 5.6K UPRIGHT (1/2"NPT) TY3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.0K UPRIGHT (3/4"NPT) TY4131 391 8.0K PEN DENT (3/4"NPT) TY4231 360 8.0K UPRIGHT (1/2"NPT) TY4831* 361 8.0K PENDENT (1/2"NPT) TY4931* SPRINKLER FINISH NATURAL BRASS 4 WHITE POLYESTER 3 WHITE (RAL9010)* 9 CHROME PLATED 7 LEAD COATED * Eastern Hemisphere sales only. TEMPERATURE RATINGS 135 135°F(57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141 °C) TABLE D PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBP. No warranty is given for prod- ucts or components manufactured by companies not affiliated by ownership with TFSBP or for products and com- ponents which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete infor- mation supplied by Buyer or Buyer's representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. express or implied, including warranties of mer- chantability and fitness for a particular purpose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*). Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. * Refer to Technical Data Sheet TFP770. Copyright © 2007-2010 Tyco Fire Suppression & Building Products. All rights reserved. v#41717A.r VAIN Schedule-1O/Scheduie-40 - M-COAT® Submittal Data Sheet > Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-10/Schedule-40 - M-COATS' sprinkler pipe from Allied Tube & Conduit, you get UL listed and FM approved products. Although these products do not require separate approvals, Schedule-10/Schedule-40 - M-COAT gives you the extra quality assurance you demand. Our Sch-10 (1-1/4" - 8") pipe and Sch-40 (1" - 2-1/2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. • Galvanized Pipe Schedule-10/Schedule-40 - M-COAT product can be "hot -dip" galvanized to meet FM requirements. > Superior Coating Our advanced formula mill coating offers a clean, durable surface that is also paintready for custom color applications without special preparation. The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula "M-COAT". > American Made Able to meet "Buy American" requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. > Specifications & Approvals Schedule-10 - M-COAT pipe is in compliance with ASTM A135, Type E Grade A, and NFPA 13. Schedule-40 - M-COAT pipe is in compliance with ASTM A135/A795, Type E Grade A, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets, Hydrostatic Pressure, Side Wall Rupture, Vibration Test. NPS In; mm • Sch-40 - Nominal I.D. In; mm M-COAT Specifications Wt. Lbs/Ft; kg/m Wt. (H20 Filled) Lbs/Ft; kg/m CRR - 1 " 1.049 1.680 2.05 1 25 26.6 2.5 3.05 - 1'/a" 1.380 2.270 2.93 1 32 35.1 4.36 4.36 - 1'h" 1.610 2.720 3.61 1 40 40.9 4.0 5.37 - 2" 2.067 3.650 5.13 1 50 52.5 5.4 7.63 - 2'/:" 2.469 5.790 7.86 1 65 62.7 8.6 11.73 - NPS In; mm Sch-1U-M-COAT Nominal I.D. In; mm Specifications Wt Lbs/Ft; kg/m 4 Wt. (H20 Filled) Lbs/Ft; kg/m CRR - 1'/4" 1.442 1.810 2.525 7.0955 32 36.6 2.7 3.75 - 11/2" 1.682 2.080 3.04 5.6570 40 42.7 3.1 4.52 - 2" 2.157 2.640 4.22 4.5827 50 54.8 3.9 6.28 - 2/" 2.635 3.530 5.89 3.5196 65 66.9 5.3 8.77 - 3" 3.260 4.330 7.94 2.5550 75 82.8 6.4 11.82 - 4' 4.260 5.610 11.78 1.6020 100 108.2 8.3 17.53 - 5 " 5.295 7.77 17.33 1.4874 125 134.5 11.56 25.80 - 6" 6.357 9.290 23.03 1.0251 150 161.5 13.8 34.27 - 8" 8.249 16.490 40.15 1.8365 200 209.5 24.5 59.75 - Project: Sprinkler Contractor: Engineer: Fe APPROVED Date: Specification Reference: System Type: Locations: Comments: YaIIied Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com • 16100 S Lathrop Ave. • 11350 Norcom Rd. Harvey, IL 60426 Philadelphia, PA 19154 • 2525 N 27th Ave. Phoenix, AZ 85009 • 600 Dean Sievers Place Morrisville, PA 19067 TUBE & CONDUIT° PARTo _Aatfkore 02011 Atkore International, Inc. NI Rights Reserved. STP-S5-4M-1111 90° ELBOW 14 SPF/RNVIL /1M/ItStar- Fire Products Division of Anvil' International Ductile Iron •jar Y 4; r ^ °� r ; Nominal Size :::. x Anvil Item Number 2t Cr. Universal Number ELBOW:,' Max- Working Pressure - . Dimensions - In.(mm) Approx. Wt. Each A B In. (mm) PSI (kPa) In. (mm) In. (mm) - , L6z (k 1 " 1 840000004 DB90033 500 1.50 1.50 0.62 20 3450 38.10 38.10 0.28 11/4 840000012 D890044 500 1.75 1.75 0.90 32 3450 44.45 44.45 0.41 11h 840000020 DB90055 500 1.94 1.94 1.20 40 3450 49.276 49.276 0.54 2 840000038 DB90066 500 2.25 2.25 1.85 50 3450 57.15 51.15 0.84 Submittal Sheet MATERIAL SPECIFICATIONS Ductile iron threaded fittings are UL & ULC Listed & Dimensions conform to ASME B16.3 Class 150. Factory Mutual Approved for 500 psi service. Threads are NPT per ANSI/ASME B 1.20.1. Ductile iron per ASTM A536 Class 65-45-12. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. APPROVED For Listing / Approval details contact your AnvilStarre Representative. PROJECII INFORMATION: APPROVAL STAMP: Project: Date: Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: SPF Cast & Ductile Iron Fittings For the latest UL/ULC Listed and FM Approved pressure atings, versus pipe schedule, REV. 03.03.06-0010 go to www.anvilstar.cam or contact your local AnvilStar representative REDUCING TEE /�niv�Star- Fire Products Division of Anvil` International Ductile Iron Nominal Size REDUCING TEE • Anvil Item Universal Max. Number Number Working Pressure Dimensions A B Approx. Wt. Each In. (mm) lxhxl 25x 1,5 x 25 lx/4x1 25.x 20 .x 25 lxlxih 15 x 2.5 .r l5 1xlx3/4 75x25x20 lxlx1%4 25x25x32 lx1x1'h 25x25x40 1/4xlx'h 3�.x25x15 1/4xlx/4 32x25x10 1/4xlxl 32x25x7,5 1'/4x1x1/4 ?x25.x37 l/4.xlx15 3Zx25x40 1/4 x 11/4 x Ih 32x.32x15 11/4 x 11/4 x 3/4 32 x 3? x 20 11/4x1/4xl 37x3xx2. 1'/4 x l /4 x l�h 37x37x40 1/4 x 11/4 X2 32x32x50 1'hxl xTh 40x25.x 15 'h 1xlx1/4 40 x 25 x 20 1'/x1xl 40.x25x25 'it 1x 1 x 1 %4 40 x 25 x 32 1'hx1x1'h 40 x 25 x 40 840004196 840004204 840004212 840004220 840004238 840004246 840004253 840004261 840004279 840004287 840004295 840004303 840004311 840004329 840004337 840004345 840004352 840004360 840004378 840004386 840004394 840004402 840004410 DT313 DT323 DT331 DT332 DT334 DT335 DT431 DT432 DT433 DT434 D1435 DT441 0T442 DT443 DT445 DT446 DT531 DT532 DT533 DT534 DT535 DT541 DT542 PSI (kPa) 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 In. (mm) 1.50 3810 1.50 38 10 1.26 32 00 1.37 34 80 1.67 42.41 1.80 45.72 1.34 34.04 1.45 36.83 1.58 40.13 1.75 44.45 1.88 47.75 1.34 34 04 1.45 36 83 1.58 4013 1.88 4775 2.10 53 34 1.41 35.81 1.52 38.61 1.65 41.91 1.82 46.23 1.94 49.28 1.41 35.81 1.52 3861 In. (mm) 1.36 34 54 1.45 36.83 1.26 32.00 1.37 34.80 1.67 42.41 1.80 45.72 1.26 32.00 1.37 34.80 1.50 38 10 1.67 42 42 1.80 45.72 1.34 34 04 1.45 36.83 1.58 40 13 1.88 4775 2.10 53.34 1.34 34.04 1.37 34.80 1.50 38.10 1.61 42.42 1.80 45.72 1.34 34.04 1.45 36 83 In. (mm) 1.50 38.10 1.50 38,10 1.36 34.54 1,45 36 83 1.58 4013 1.65 41.91 1.53 38 96 1.62 4115 1.67 4247 1.75 44.45 1.82 46.22 1.53 38.86 1.62 41.15 1.67 42.42 1.82 46.22 1.90 48.26 1.66 42 16 1.75 44.45 1.80 45 72 1.88 4775 1.94 49.28 1.66 42.16 1.75 44 45 Ibs.(kg) 0.64 0.29 0.73 0.33 0.71 0.32 0.76 0.34 0.98 0.44 1.16 0.53 0.82 0.37 0.90 0.41 1.00 0.45 1.08 049 1.42 0.64 0.86 0.39 0.92 0.42 0.95 0.43 1.45 0.66 1.75 0.79 0.95 0.43 1.14 0.52 1.17 0.53 1.34 0.61 1.45 0.66 1.05 0 48 1.15 0-57 Submittal Sheet ., ..- -" . REDUCING TEE Nominal Size Anvil Item Number Universal Number Max' Working Pressure Dimensions Approx. Each A B In. (mm) (kPa) In_ (mm) In. (mm) In. (mm) lbs.(kg) 11/2 x 11/4 x 1 840004428 DT543 500 1.65 1.58 1.80 1.25 � x 32 x 25 3450 41.91 90.13 0.57 11/2 x 1 i4 x 2 840004436 DT546 500 2.16 2.10 _45.72 2.02 1.90 40 x 37 x 50 3450 54.86 53 34 5130 0.86 1'h x 1Tt x n 840004444 DT551 500 1.41 1.41 1.16 1.15 40 .x 40 x 1 35 81 315.5821 29 0 52 x 1'h l 1h x''4 840004451 DT552 5003450 1.52 1.52 1.1546 1.24 40 x 45 x 20 3450 38.61 38 61 44 45 0 56 11/2 x 1 /2 x 1 840004469 DT553 500 1.65 1.65 1.80 1.30 40 x 40 x 25 3450 91,91 41.91 45 72 0.59 1 h x 1 h x 11/4 840004477 DT554 500 1.82 1.82 1.88 1.48 40 x 40 x 32 3450 46 23 46.73 47 75 0 67 11/2 x 11 x 2 840004485 DT556 500 2.16 2.16 2.02 1.98 40 x 40 x 50 3450 54 86 54.86 51.30 0.90 2 x l x 2 840004493 DT636 500 2.25 2.02 2.25 2.15 50x25x50 3450 5715 51.31 57.15 098 2 x l /4 x 2 840004501 DT646 500 2.25 2.10 2.25 2.30 50 x 332 x .50 3450 5715 53.34 57.15 104 2 x 1 i2 x h 840004519 DT651 500 1.49 1.41 1.88 1.50 50 x 40 x 15 3450 37.85 35.81 47.75 0.68 2 x 1'/2 x 14 840004527 D1652 500 1.60 1.52 1.97 1.62 50 x 40 x 20 3450 40.64 38.61 50.04 0.73 2 x 1' x 1 840004535 DT653 500 1.73 1.65 2.02 1.64 50 x 40 x 2,5 3450 43.94 41.91 51.31 0.74 2 x 11/2 x 1 /4 840004543 DT654 500 1.90 1.82 ' 2.10 1.80 50 x 40 x 32 3450 49.26. 46.23 53.34 0.82 2 x 11h x l 1 840004550 DT655 500 2.02 1.94 2.16 2.00 50 x 40 x 40 3450 51.31 49.28 54.86 0.91 2 x 11/2 x 2 840004568 DT656 500 2.25 2.16 2.25 2.35 50 x 40 x 50 3450 57.15 54.86 57.15 1.07 2 x 2 x1/2 840004576 DT661 500 1.49 1.49 1.88 1.60 50 x 50 x 15 3450 37.85 37 85 4775 0.73 2 x 2 x 3/4 840004584 DT662 500 1.60 1.60 1.91 1.68 50 x 50 x 20 3450 40.64 40.64 50.04 0,76 2 x 2 x 1 840004592 D1663 500 1.73 1.73 2.02 1.85 50 x 50 x 25 3450 43 94 43 94 5131 0 84 2 x 2 x 114 840004600 DT664 500 1.90 1.90 2.10 2.04 50 x 50 x 32 3450 44 4.5 42.42 44 45 0 93 2 x 2 x 11/2 840004618 DT665 500 2.02 2.02 2.16 2.18 50 x 50 x 40 3450 44 45 42.42 44.45 0.99 2 x 2 x 21/2 - DT667 500 2.60 2.60 2.39 3.61 50 x 50 v.55 3450 44 45 4242 44.45 164 21/2 x 2 x 74 • 01762 500 1.74 1.60 2.32 2.28 65 x 50 x 20 3450 44 45 4747 44,45 103 MATERIAL. SPECIFICATIONS Ductile iron threaded fittings are UL & ULC Listed & Dimensions conform to ASME B16.3 Class 150. Factory Mutual Approved for 500 psi service. Threads are NPT per ANSI/ASME B1 .20.1. Ductile iron per ASTM A536 Class 65-45-12. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron finings should be tightened three turns beyond hand tight, but no more than four turns. APPROVED For Listing / Approval details contact your AnvilStarTm Representative. ROJEC1,INFORMATIQN • PPROVAC STAMP: Project: Date: Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: SPF Cast & Ductile Iron Fittings REV. 03,03.06-0014 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, =��'L go to www.anvilstar.com or contact your local AnvilStar representative e.taaaMBCQ Revision 12/18/2008 Fig. 200 - "Trimline" Adjustable Band Hanger Fig. 200R (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. • (21/2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By — Figure number and pipe size Note — Figure 200R (import) with retainer ring and non -captured knurl nut. Fig. 200R 212" - 8" Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. WtJ100 1/2 3/8 8mm or 10mm 31/8 25/8 400 11 3/4 3/8 8mm or 10mm 31/2 212 400 11 1 3/8 8mm or 10mm 33/8 25/e 400 12 11/4 3/8 8mm or 10mm 33/4 21 400 13 1 1 3/8 8mm or 10mm 31/8 2%/8 400 14 2 3/8 8mm or 1 Omm 41 3 400 15 21/2 3/8 10mm 5% 41/8 600 27 3 3/8 10mm 51 4 600 29 31/2 3/8 10mm 73/8 51/4 600 34 4 3/8 10mm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63 1250 73 8 1/2 12mm 131/8 83 1250 136 c0 us usn:n Fig. 200 21" - 8" Fig. 200R 1/2" - 2" OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.rolco.com 91 www.tolco.com Revision 12/28/2010 Fig. 68S and 68W - Malleable, Reversible Beam Clamps 3/4" and 1-1/4" Throat Openings Size Range — 3/8" thru 7/8" rod Material — Cast Malleable Steel with hardened cup point set screw and jam nut Function — Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 68S) or 1-1/4" (Fig. 68W) Features — May be used on top or bottom flange of the beam. Beveled lip allows hanging from top flange where clearance is limited. may be installed with the set screw in the up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. The rear window design permits inspection of thread engagement. Approvals — Factory Mutual Engineering Approved. Underwriters Laboratories Listed. Conforms to Federal Specification WW-H-171 E, Type 23 and Manufacturers Standardization Society SP-58, Type 19. Fig. 68S 3/8" is cULus Listed to support up to 4" pipe with the set screw in the down position, up to 3" pipe with the set screw in the up position. Fig. 68S 1/2" is cULus Listed to support up to 8" pipe with the set screw in the down position, up to 6" pipe with the set screw in the up position. Fig. 68W 3/8" is cULus Listed to support up to 4" pipe with the set screw in the down position, up to 4" pipe with the set screw in the up position. Fig. 68W 1/2" is cULus Listed to support up to 6" pipe with the set screw in the down position, up to 6" pipe with the set screw in the up position. Factory Mutual Engineering approved only with the set screw in the down position. Finish — Plain Note — Available in Electro-Galvanized and HDG finish Order By — Figure number, rod size & finish Fig. 68S Rod Size A Dimensions • Weights BCD E F Max. Rec. Max. Rec. Max. Rec. Torque Load Lbs. Load Lbs. Approx. Ft/Lbs.Set screw Set screw WtJ100 up down 3/8 3/8 1-1/2 3/4 1-1/8 7/16 7/8 5 610 610 32 1/2 3/8 1-5/8 3/4 1 7/16 1-1/8 5 750 1130 54 5/8 1/2 1-9/16 3/4 1 9/16 1-1/8 11 750 1130 50 3/4 1/2 1-3/4 3/4 1-1/8 9/16 1-1/4 11 750 1130 81 7/8 1/2 1-3/4 3/4 1-1/8 9/16 1-5/16 11 750 1130 75 Fig. 68W Dimensions • Weights Max. Rec. Max. Rec. Max. Rec. Rod Load Lbs. Load Lbs. Approx. Size A B C D E F Torque Set screw Set screw WtJ100 Ft/Lbs. up down 3/8 3/8 1-9/16 1-1/4 1-1/8 7/16 13/16 5 610 610 41 1/2 1/2 1-9/16 1-1/4 1 5/8 1-1/8 5 750 1130 66 5/8 1/2 1-1/2 1-1/4 1 9/16 1-1/8 11 750 1130 68 3/4 1/2 1-3/4 1-1/4 1-1/8 3/8 1-1/4 11 750 1130 110 7/8 1/2 1-3/4 1-1/4 1-1/8 9/16 1-5/16 11 750 1130 98 NOTE: Install per set screw requirements of MSS SP-58; 3/8" = 5ft/lbs., 1/2" = 11ft/lbs. Since torque wrenches are generally not used or available on most job sites. Standard practice is to tighten the set screw "finger tight" than additionally tighten 1/4 turn. APPROVED B I US LISTED OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 64 EXIST. TO REMAIN N W �I S KEY PLAN NTS. oppicp cop), REVIEWED FOR COMPLIANCE Na approval shall not be construed as authorftyt violate, cancel, alter or set aside any provisions of any state or local governing authority regulating constructcn or the performance of construction. All provisions of law and ordinances governing This type of work mustbe complied with whether herein specified or not Nor shall approval of these plans prevent the Fhe Department from requiring � for ulri_ :, oorreccorrectionsIs ) y Date: Job: AMSPEC 191 CENTER STREET CAPE CANAVERAL, FL. Contractor ORANGEMEN CORP. 1858 MURPHY ST. OVIEDO, FL. 32765 E-� U) Plan Review To: Building Department From: John J. Cunningham, Fire MarshalW. Re: 191 Center Street Fire Sprinkler plans Date: 04-29-2016 CO, We have reviewed the plans and have no comments at this time. Plan Review Fee: $;25.00, Station #1: 190 Jackson Avenue • Cape Canaveral, Florida 32920 • (321) 783-4777 • Fax: (321) 783-5398 Station #2: 8970 Columbia Road • Cape Canaveral, Florida 32920 • (321) 783-4424 • Fax: (321) 783-4887 www.ccvfd.org