Loading...
HomeMy WebLinkAbout200-52528-14001 LS 6 AND 7-ADDENDUM-2DETAIL2 -SCALE: N.T.S. DETAIL4 -SCALE: N.T.S.DETAIL1 -SCALE: N.T.S. NOTES: 1.CLEANOUT SHALL BE INSTALLED BY THE CONTRACTOR IN ACCORDANCE WITH STANDARD PLUMBING CODE. 2.INVERT OF SERVICE LATERAL SHALL NOT ENTER SEWER MAIN BELOW SPRING LINE. 3.:<(6$1'ƒ%(1'66+$//%(39& 6'5  FINISHED GRADE DOUBLE WYE DOUBLE LATERAL PLUMBER TO ADJUST TO FINISHED GRADE LOT LINE CLEAN-OUT SEE NOTE 1 R/W LINEPLUG WYE WITH 6" BRANCH ƒ%(1'R/W6" 45's 6" LATERAL TERMINAL DEPTH AS REQUIRED FOR "HOUSE" SERVICE (3' MIN.) - TYP. 4' MAXIMUM DEPTH 527$7(ƒ (TYP.)(SEE NOTE 2) SINGLE LATERAL VARIES PLAN SLOPE TO TERMINAL DEPTH AT 1.0% MIN. (TYP.) PROFILE CLEAN-OUT (TYP.) SEE NOTE 1 WYE WITH 6" BRANCHR/W LINEƒ BEND WYE WITH 6" BRANCH SEWER MAIN SIZE VARIES R/WVARIES 18"DETAIL3 -SCALE: N.T.S. PVC PVC TEE GRAVITY OUTSIDE DROP CONNECTION (NEW MANHOLE) NOTES: 1.DROP PIPE AND FITTINGS SHALL BE OF EQUAL SIZE AND MATERIAL AS THE INFLUENT SEWER. 2.AN OUTSIDE DROP CONNECTION SHALL BE REQUIRED FOR ALL INFLUENT LINES WHICH HAVE AN INVERT 2' OR MORE ABOVE THE MANHOLE INVERT. 3.CONTRACTOR TO COORDINATE THE PRESENCE OF UTILITIES INSPECTOR DURING CORING AND CONNECTIONS TO EXISTING MANHOLES. PRECAST MANHOLE WALL INLET CONNECTION AT INVERT CONCRETE ENCASEMENT OF VERTICAL PIPE DROP PIPE (SEE NOTE 1) ƒ%(1' 2" INFLUENT SEWER (SEE NOTE 2) PRECAST MANHOLE WALL STAINLESS STEEL BAND RESILIENT CONNECTOR STAINLESS STEEL PIPE CLAMP PRECAST MANHOLE WALL CAST IN-PLACE SEAL STANDARD CONNECTION PVC PLUG WITH TOP HALF AREA OPEN GRAVITY OUTSIDE DROP CONNECTION (EXISTING MANHOLE) NEW AND EXISTING MANHOLES NEW MANHOLES ONLY GRAVITY MANHOLE CONNECTION 6" MIN 6" MIN 6" MIN 6" MIN ƒ+22.$72&(: NOTES: 1. DROP CONNECTIONS ARE REQUIRED WHENEVER INVERT OF INFLUENT SEWER IS 24" OR MORE ABOVE THE INVERT OF THE MANHOLE. SEE MANHOLE CONNECTION DETAILS. ALL DROPS TO BE OUTSIDE OF THE MANHOLE. 2. E-Z RAPP OUTSIDE ALL JOINTS 3. GROUT WITH NON-SHRINKING GROUT INSIDE JOINTS 4. NO CONES OVER 3 FT. TALL 5. ALL PRECAST CONCRETE SHALL BE COATED INSIDE AND OUTSIDE PER SPECIFICATION 03480. SECTION INSIDE WALL MANHOLE FRAME & COVER (SEE STANDARD DETAIL) 1 COURSE OF BRICK (MIN.) 4 COURSES (MAX.) PRE-PRIMED JOINT SURFACES COMPLETED JOINT WITH SQUEEZE-OUPRECAST MONOLITHIC BASE SET COVERS FLUSH IN PAVED AREAS & AT ELEVATIIONS SHOWN IN UNPAVED AREAS. BENCHING PER SPECIFICATIONS CAST-IN-PLACE CONCRETE BASE COATINGS PER SPECIFICATIONS (SEE NOTE 5) PLAN BEDDING ROCK CRUSHED CONCRETE 3/8" FINES PRECAST SANITARY MANHOLE GROOVE & O-RING 25 3/4" 24" 35 1/2" FLAT GASKET 7"RAISED 1 1/2" LETTERS FLUSH WITH TOP OF COVER 24" 32 1/2"8"TYPE "A" MANHOLE FRAME AND COVER TYPE "A" SECTION TYPE "A" & "B" NON-BOLTED WATERTIGHT RING & COVER US FOUNDRY NO. 227-AS-ORS (TYPE "A") & NO. 1295-AS-ORS (TYPE "B") OR APPROVED EQUAL. MANHOLE COVERS SHALL BE LABELED AS SHOWN ABOVE. TYPE "B" SECTION TYPE "B" MANHOLE FRAME AND COVER 25 3/4" (BUILT UP TYPE)(SLAB TYPE) NOTES: MANHOLE FRAME AND COVER SANITARY SEWER SERVICE LATERALGRAVITY MANHOLE CONNECTION PIPE SUPPORT - ADJUSTABLE STANCHION W/ U-BOLT DETAIL8 SCALE: NTS PIPE SIZE A B C D E MIN MAX 4 4 4 3/16 7 3 9 1/2 14 6 4 5 7/16 7 3 10 3/4 15 1/4 8 4 6 15/16 7 3 12 1/4 16 3/4 10 4 8 7/16 7 3 13 3/4 18 1/4 12 4 9 15/16 7 3 14 5/8 19 1/8 16 4 11 1/2 7 3 16 13/16 21 5/16 18 6 13 1/2 9 3 1/2 19 1/8 23 5/8 20 6 14 1/2 9 3 1/2 20 1/8 24 5/8 24 6 17 1/2 9 4 23 5/16 27 13/16 NOTES: 1.SCH 40 SST ENTIRE PIPE SUPPORT AFTER FABRICATION (STAINLESS STEEL FASTENING HARDWARE). 2.SEE PLANS AND SECTIONS FOR PIPE GRADE REQUIREMENT (DIMENSION "E"). 3.PROVIDE INSULATION PROTECTION SHIELD (GRINNELL FIG 167 OR EQUAL) WHEN PIPING IS INSULATED. PROCESS PIPE 316 SST U-BOLT 1/4" NEOPRENE PAD ANVIL FIG 265 PIPE STANCHION SADDLE OR EQUAL SCHEDULE 40 SST PIPE CUT TO MEET REQUIRED PIPE GRADE 1" NON-SHRINK GROUT 1/2" THICK SQUARE SST PLATE 5/8" SST WEDGE ANCHORS WITH LEVELING NUTS (TYP OF 4) CONSTRUCT 18"x18"x6" CONC BASE W/ #4 @ 6" OC, EW IF SUPPORT IS NOT LOCATED ON AN EXISTING SLAB.C 1" AEB D * ALL DIMENSIONS IN INCHES.5'-0" MAXDETAIL5 -SCALE: N.T.S. DETAIL6 -SCALE: N.T.S. DETAIL7 -SCALE: N.T.S. WALL PENETRATION - LINK SEAL (CORE-DRILLED)SEE TABLE"A"PIPE SIZE (IN) NOMINAL OPENING "A" (IN) 1 3 2 4 2-1/2 4 3 5 4 6 6 10 8 12 PIPE SIZE (IN) NOMINAL OPENING "A" (IN) 10 14 12 16 14 16 16 18 18 23 20 25 24 29 EXISTING CONCRETE WALL PIPE SLEEVE FOR WALL PENETRATION SEAL ASSEMBLY BY MFR PIPE, SEE PLANS FOR SIZE LINK-SEAL WALL PENETRATION SEAL ASSEMBLY HOSE BIBBSEWER CLEANOUT UNDISTURBED SOIL 2'-6" SQ FINISHED GRADE CLEANOUT COLLAR TO BE THREADED FRAME AND COVER TO BE MORITZ FOUNDRY, M-1240; ALHAMBRA FOUNDRY, A-1240, OR APPROVED EQUAL CLASS "A" CONCRETE COLLAR EXPANSION JOINT MATERIAL ƒ%(1' ',30- ƒ%(1'25:<( (DIP, MJ) NOTE: SEE YARD PIPING DWGS FOR PIPE MATERIAL AND SIZE ƒ(/%2:PVC TO BRASS ADAPTER 1" SCH 80 PVC PIPE 1" BRASS PIPE SECURE TO POST WITH 316 SS STRAPS ANTI-SIPHON DEVICE 3/4" BRASS HOSE BIB ;ƒ(/%2: 1- #4 REBAR 4"X4" PRECAST CONCRETE POST 1" CURB STOP ALUMINUM OR 316 SS HOSE HANGER 18" MIN2'-0" MINCOVER24" (TYP)www.tetratech.comMARKDATEDESCRIPTIONBY2/20/2015 10:01:16 AM - \\IERS181FS1\PROJECTS\IER\52528\200-52528-14001\CAD\SHEETFILES\C-501 DETAILS.DWG - BURDIEL, NAPOLEON1 A B C D E F 2 3 4 5 6 7 Bar Measures 1 inch Copyright: Tetra TechLIFT STATION NO. 6 AND 7 IMPROVEMENTS201 EAST PINE STREET, SUITE 1000ORLANDO, FLORIDA 32801PHONE: (407) 839-3955 FAX: (407) 839-3790Engineering Business No. 2429C-502DETAILS21 02/20/15 ADDENDUM 2 A-BOR TH-1 6" DIP STUB ELEV 7.57 SVFMFMxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxx xx xx xx xx xx xx xx 1 ' 'WWWWPROP. SS MH 1 TOP 8.40 NW INV. -3.53 W INV. -3.63 S INV. -1.90 9'-6" 8 C502 PROP 6" FM 5'-0"1" DRAINPER MANUFACTURER REQUIREMENTS PROP WET WELL W/ NEW PUMP, DISCHARGE PIPING & TOP SLAB E INV -3.69 SST PIPE SUPPORT (TYP) 1/2" EXPANSION JOINT W/ BACKER ROD & SEALANT 6" SLAB OPENING FOR LEVEL TRANSDUCER AL SAFETY HATCH 42"x60" (SEE NOTE 3 THIS SHEET) PROP ELECTRICAL CONTROL PANEL 6" MIN. CLEARANCE ALL SIDES6" MIN.6" MIN.4" 316 SS (SCH40) GOOSNECK VENT W/ 316 SS SCREEN PROP 1" PW 14 LF OF 8" PVC SS90 LF OF 8" PVC SS 316 SST FLOAT CABLE HOLDER (TYP) HOSE BIBB BFP WATER METER ƒ%(1' CONNECT TO EXISTING FM  ƒ%(1'6 EXISTING PROPERTY BOUNDARY EXISTING FM DOUBLE GATE 1" WATER SERVICE 1 C-503 7 C-502 CONTRACTOR SHALL USE EXISTING EMERGENCY PUMP OUT DURING CONSTRUCTION 32.00' PROP 6" CONC EQUIP PAD #4 BARS 12 OCEW PROP 12" PRECAST CONC TOP SLAB (SEE NOTE 1 THIS SHEET) PROP HDPE WET WELL LINER (SECTION 09920) 36" WET WELL ELECTRICAL CONDUIT TO CONTROL PANEL PROP POWER CABLE PROP 316 SST GUIDE RAIL ƒ%(1' )/* 7<3 OFFSET PIPE SUPPORT (316 SST SPACED A MIN 5'-0") 3'-0" MIN COVER (TYP.) PUMP MOUNTED ON BASE PLATE, ANCHORED PER MANUFACTURERS RECOMMENDATIONS PROP LIFTING CHAIN (MIN 1/4" SST CHAIN) 3" ƒ%(1' 0- (ROTATED FOR CLARITY) 7 C-504 7 E-401  ‘ 12" 18" FIN FL EL -9.00 T/SLAB EL 7.50 PRECAST MONOLITHIC BASE (ASTM C478) 12" MIN 1" DRAIN (PVC) (SLOPE @ 1% MIN. TO WET WELL) INV EL -3.69 PROP 8" SS SLOPE PROP GROUT AS PER PUMP MFR RECOMMENDATIONS HWL EL -3.72 LAG PUMP ON EL -4.22 ALL OFF EL -7.00 INSTALLED BY CONTRACTOR AND SET BY CITY 24" PROP WALL PENETRATION SEAL 7 C-501 FDOT NO. 57 STONE 6" DIP CHECK VALVE 6" PV (FLG)(TYP) 6" EXPANSION COUPLING W/ 316 SST TIE RODS (FLG)(TYP)FLANGED PRESSURE WAFER W/ PRESSURE GAUGE (TYP) AIR RELEASE VALVE W/ 2" NPT PROP ELEC CONTROL PANEL (ROTATED FOR CLARITY) ƒ%(1' 7<3 6" WYE (FLG) (TYP) 2" 316 SST BALL VALVE 4" 316 SS (SCH40) GOOSENECK VENT W/ 316 SS SCREEN (ROTATED FOR CLARITY) 1/2" EXPANSION JOINT W/ BACKER ROD AND SEALANT 6" SST RESTRAINED FAC W/ 316 SST HARDWARE (TYP) 316 SST FLOAT HANGER 3523 ‘ ,' 35(&$67 CONC WET WELL (ASTM C478) 6"x6" TEE (FLG) EPDM KOR-N-SEAL W/ SST WEDGE PROP FILTER FABRIC & 6" FDOT GRANITE NO. 57 STONE (TYP) SEALER & HEAT SHRINK SEAL (TYP) FRP NECK AROUND HATCH OPENING TOP SLAB PENETRATION SEAL (TYP) 1" TRUE UNION 6"X4" REDUCER (FLG) (IF REQUIRED BASED UPON PUMP SELECTION) LEAD PUMP ON EL -4.72 PROP AL SAFETY HATCH PIPE MATERIAL SCHEDULE: WET WELL -SCHEDULE 40 SST ABOVE GRADE -SCHEDULE 40 SST BELOW GRADE -PVC DR-18 6" SST PIPE 6" SST PIPE 6" SST PIPE 6" PAD W / #5AT12" T&B 6 C502 6" SST PIPE (FLG) 6" FILTER FABRIC LINER 6" 12" 5 C-504 ƒ%(1' )/* 7<3 N PLAN VIEW SCALE: 3/8" = 1'-0" SECTION VIEW "A" SCALE: 3/8" = 1'-0"www.tetratech.comMARKDATEDESCRIPTIONBY2/20/2015 10:01:22 AM - \\IERS181FS1\PROJECTS\IER\52528\200-52528-14001\CAD\SHEETFILES\D-101 LS NO.6.DWG - BURDIEL, NAPOLEON1 A B C D E F 2 3 4 5 6 7 Bar Measures 1 inch Copyright: Tetra TechLIFT STATION NO. 6 AND 7 IMPROVEMENTS201 EAST PINE STREET, SUITE 1000ORLANDO, FLORIDA 32801PHONE: (407) 839-3955 FAX: (407) 839-3790Engineering Business No. 2429D-101LS NO. 6LIFT STATIONPLAN & SECTIONNOTES: 1.WET WELL TOP SLAB SHALL HAVE A MINIMUM THICKNESS OF 12" AND CONFORM TO ASTM C478. THE SLAB SHALL BE DESIGNED FOR AASHTO H20 LOADING. REINFORCING IN THE SLAB SHALL BE A MINIMUM OF #5@6" O/C, TOP AND BOTTOM, 2" CLEAR. PROVIDE (2) #7 BARS ADJACENT TO OPENINGS (FULL LENGTH OF SLAB). THE CONCRETE SHALL MEET THE MINIMUM COMPRESSIVE STRENGTH fc=4,000PSI AND THE REINFORCING SHALL MEET A YIELD STRENGTH Fy=60,00 PSI. 2.EQUIPMENT AND PIPING ROTATED FOR CLARITY. 3.CONTRACTOR SHALL COORDINATE WITH PUMP MANUFACTURER AND ACCESS HATCH MANUFACTURER FOR FINAL HATCH DIMENSIONS TO ALLOW ADEQUATE CLEARANCE (6" MIN.) FOR PUMP REMOVAL. 4.ALL FM PIPING AND APPURTENANCES SHALL BE RESTRAINED. 5.ALL ABOVE GRADE FORCEMAIN AND FORCEMAIN DISCHARGE PIPING IN WET WELL SHALL BE SCH 40 316 SST. SUBMERSIBLE PUMP SPECIFICATIONS Parameter LS No. 6 Pumps Number of Pumps 2 Pump Type Standard Submersible Type of Drive Constant Speed Design Capacity per Pump, GPM/Ft. TDH 580 / 29.5 610 / 31.5 Minimum Shut Off Head, Ft.68 54 Run Out-Head, Ft.7 9 Minimum Capacity at Run-Out Head, gpm 960 1,200 Minimum Efficiency at Design Capacity 64%66% Minimum Size Solids, Passing, In.3 3.9 Minimum Discharge Size, In.4 6 Minimum Horsepower Per Pump, HP 7.5 10.1 Basis of Design Pump MFR & Pump Model/Impeller Flygt Model NP 3127 Series / 195 mm ABS Model XFP 150E-CB1-PE75 / 4 190mm 1 1 02/09/15 ADDENDUM 11 1 2 2 02/20/15 ADDENDUM 2 UTUTRWRWUTVUTVUTVIRRIRRIRROEOESSBOR TH 1 4.5" PVC IRR MAIN GR 4.3' TOP OF PIPE DEPTH 2.25' BOR TH 2 2.5" UE 2.05' DEEP 1" UT 3.15' DEEP GR 4.5'xxxxxxxxxxxxxxxxxxxxxxSS SS1''WFMFMEXISTING MH TOP 4.38 S INV. -3.42 N INV. -3.47 PROP. SS MH 1 TOP 4.00 W INV. -9.27 E INV. -9.17 EX. S INV. -3.65 9'-6" PROP 8" FM 14 LF OF 12" PVC SS 5'-0" 2" DRAIN PER MANUFACTURER REQUIREMENTS PROP WET WELL W/ NEW PUMP, DISCHARGE PIPING & TOP SLAB4" QUICK CONNECT FOR PUMP-OUT CONNECTION SST PIPE SUPPORT (TYP) 316 SST FLOAT CABLE HOLDER (TYP) 1/2" EXPANSION JOINT W/ BACKER ROD & SEALANT 6" SLAB OPENING FOR LEVEL TRANSDUCER PROP WET WELL AL SAFETY HATCH 42"x60" (SEE NOTE 3 THIS SHEET) PROP ELECTRICAL CONTROL PANEL 6" MIN. CLEARANCE ALL SIDES6" MIN. 6" MIN. 4" 316 SS (SCH40) GOOSNECK VENT W/ 316 SS SCREEN PROP 1" PW PROP. SS MH 2 TOP 4.82 W INV. -9.09 N INV. -8.99 37 LF OF 12" PVC SS PROP BFP  ƒ%(1'6 8"X10" WET TAP LINE STOPPROP 8" FM PROP 6"X4" TEE PROP 6" FM CONCRETE DRIVE PROP 1" WATER SERVICE CAP INSTALL VALVE HORIZONTALLY CAP HOSE BIBB 32.00'PROP GRADE TO EXST 10" FM PROP HDPE WET WELL LINER (SECTION 09920) 36" WET WELL ELECTRICAL CONDUIT TO CONTROL PANEL PROP POWER CABLE PROP 316 SST GUIDE RAIL ƒ%(1' )/* 7<3 OFFSET PIPE SUPPORT (316 SST SPACED A MIN 5'-0") 3'-0" MIN PUMP MOUNTED ON BASE PLATE, ANCHORED PER MANUFACTURERS RECOMMENDATIONS PROP LIFTING CHAIN (MIN 1/4" SST CHAIN) 3" ƒ%(1' 0- (ROTATED FOR CLARITY)  ‘ 12" 18" FIN FL EL -15.50 T/SLAB EL 4.00 PRECAST MONOLITHIC BASE (ASTM C478) 12" MIN 2" DRAIN (PVC) (SLOPE @ 1% MIN. TO WET WELL) INV EL -9.30 PROP 12" SS SLOPE PROP GROUT AS PER PUMP MFR RECOMMENDATIONS HWL EL -9.79 LAG PUMP ON EL -10.29 ALL OFF EL -13.50 INSTALLED BY CONTRACTOR AND SET BY CITY 24" PROP WALL PENETRATION FDOT NO. 57 STONE 6" CV (FLG)(TYP) 6" PV (FLG)(TYP)6" EXPANSION COUPLING W/ 316 SST TIE RODS (FLG)(TYP) FLANGED PRESSURE WAFER W/ PRESSURE GAUGE (TYP) AIR RELEASE VALVE W/ 2" NPT PROP ELEC CONTROL PANEL (ROTATED FOR CLARITY) ƒ%(1' 7<3 6" WYE (FLG) (TYP) 6"x4" TEE (FLG), 4" PV (FLG)(TYP) PROP AL SAFETY HATCH PROP 6" CONC EQUIP PAD WITH #4 BARS 12" OCEW 2" 316 SST BALL VALVE PROP 12" PRECAST CONC TOP SLAB (SEE NOTE 1 THIS SHEET) 4" 316 SS (SCH40) GOOSENECK VENT W/ 316 SS SCREEN (ROTATED FOR CLARITY) 1/2" EXPANSION JOINT W/ BACKER ROD AND SEALANT 6" RESTRAINED FAC W/ 316 SST HARDWARE (TYP) 316 SST FLOAT HANGER 3523 ‘ ,' &21&:(7:(// $670& 6"x8" TEE (FLG) 8" STUB-OUT W/ 8" VERTICAL PLUG VALVE. TEMPORARY BY-PASS AND PIG LAUNCH PORT. EPDM KOR-N-SEAL W/ SST WEDGE PROP FILTER FABRIC & 6" FDOT GRANITE NO. 57 STONE (TYP) SEALER & HEAT SHRINK SEAL (TYP) FRP NECK AROUND HATCH OPENING TOP SLAB PENETRATION (TYP) 2" TRUE UNION 6"X4" REDUCER (FLG) (IF REQUIRED BASED UPON PUMP SELECTION) LEAD PUMP ON EL -10.79 6" SST PIPE 6" SST PIPE 6" SST PIPE ƒ%(1' )/* 7<3 6" SST PIPE (FLG) N PLAN VIEW SCALE: 3/8" = 1'-0" A - SECTION VIEW "A" SCALE: 3/8" = 1'-0" PIPE MATERIAL SCHEDULE: WET WELL -SCHEDULE 40 SST ABOVE GRADE -SCHEDULE 40 SST BELOW GRADE -PVC www.tetratech.comMARKDATEDESCRIPTIONBY2/20/2015 10:01:36 AM - \\IERS181FS1\PROJECTS\IER\52528\200-52528-14001\CAD\SHEETFILES\D-102 LS NO.7.DWG - BURDIEL, NAPOLEON1 A B C D E F 2 3 4 5 6 7 Bar Measures 1 inch Copyright: Tetra TechLIFT STATION NO. 6 AND 7 IMPROVEMENTS201 EAST PINE STREET, SUITE 1000ORLANDO, FLORIDA 32801PHONE: (407) 839-3955 FAX: (407) 839-3790Engineering Business No. 2429D-102LS NO. 7LIFT STATIONPLAN & SECTIONNOTES: 1.TOP SLAB SHALL HAVE A MINIMUM THICKNESS OF 12" AND CONFORM TO ASTM C478. THE SLAB SHALL BE DESIGNED FOR AASHTO H20 LOADING. REINFORCING IN THE SLAB SHALL BE A MINIMUM OF #5@6" O/C, TOP AND BOTTOM, 2" CLEAR. PROVIDE (2) #7 BARS ADJACENT TO OPENINGS (FULL LENGTH OF SLAB). THE CONCRETE SHALL MEET THE MINIMUM COMPRESSIVE STRENGTH fc=4,000PSI AND THE REINFORCING SHALL MEET A YIELD STRENGTH Fy=60,00 PSI. 2.EQUIPMENT AND PIPING ROTATED FOR CLARITY. 3.CONTRACTOR SHALL COORDINATE WITH PUMP MANUFACTURER AND ACCESS HATCH MANUFACTURER FOR FINAL HATCH DIMENSIONS TO ALLOW ADEQUATE CLEARANCE (6" MIN.) FOR PUMP REMOVAL. 4.ALL FM PIPING AND APPURTENANCES SHALL BE RESTRAINED. 1 C-503 8 C-504 7 C-502 6 C-502 7 C-501 SUBMERSIBLE PUMP SPECIFICATIONS Parameter LS No. 7 Pumps Number of Pumps 2 Pump Type Standard Submersible Type of Drive Constant Speed Design Capacity per Pump, GPM/Ft. TDH 1,080 / 61.4 1,058 / 59.5 Minimum Shut Off Head, Ft.126 110 Run Out-Head, Ft.37 39 Minimum Capacity at Run-Out Head, gpm 1,480 1,510 Minimum Efficiency at Design Capacity 72%69% Minimum Size Solids, Passing, In.3 3.9 Minimum Discharge Size, In.4 6 Minimum Horsepower Per Pump, HP 25 25 Basis of Design Pump MFR & Pump Model/Impeller Flygt Model NP 3171 Series / 256 mm ABS MODEL XFP 150G-CB1-PE185/4 250mm 5 C-504 1 02/09/15 ADDENDUM 11 1 1 2 2 02/20/15 ADDENDUM 2